Literature DB >> 23060069

Development of a novel multi-point plastic scintillation detector with a single optical transmission line for radiation dose measurement.

François Therriault-Proulx1, Louis Archambault, Luc Beaulieu, Sam Beddar.   

Abstract

The goal of this study was to develop a novel multi-point plastic scintillation detector (mPSD) capable of measuring the dose accurately at multiple positions simultaneously using a single optical transmission line. A 2-point mPSD used a band-pass approach that included splitters, color filters and an EMCCD camera. The 3-point mPSD was based on a new full-spectrum approach, in which a spectrograph was coupled to a CCD camera. Irradiations of the mPSDs and of an ion chamber were performed with a 6 MV photon beam at various depths and lateral positions in a water tank. For the 2-point mPSD, the average relative differences between mPSD and ion chamber measurements for the depth-dose were 2.4±1.6% and 1.3±0.8% for BCF-60 and BCF-12, respectively. For the 3-point mPSD, the average relative differences over all conditions were 2.3±1.1%, 1.6±0.4% and 0.32±0.19% for BCF-60, BCF-12 and BCF-10, respectively. This study demonstrates the practical feasibility of mPSDs. This type of detector could be very useful for pre-treatment quality assurance applications as well as an accurate tool for real-time in vivo dosimetry.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23060069      PMCID: PMC3849702          DOI: 10.1088/0031-9155/57/21/7147

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  17 in total

1.  Miniature scintillating detector for small field radiation therapy.

Authors:  D Létourneau; J Pouliot; R Roy
Journal:  Med Phys       Date:  1999-12       Impact factor: 4.071

2.  Surface preparation and coupling in plastic scintillator dosimetry.

Authors:  Guylaine Ayotte; Louis Archambault; Luc Gingras; Frédéric Lacroix; A Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2006-09       Impact factor: 4.071

3.  Measurement accuracy and cerenkov removal for high performance, high spatial resolution scintillation dosimetry.

Authors:  Louis Archambault; A Sam Beddar; Luc Gingras; René Roy; Luc Beaulieu
Journal:  Med Phys       Date:  2006-01       Impact factor: 4.071

4.  Clinical prototype of a plastic water-equivalent scintillating fiber dosimeter array for QA applications.

Authors:  Fréderic Lacroix; Louis Archambault; Luc Gingras; Mathieu Guillot; A Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

5.  Cerenkov-free scintillation dosimetry in external beam radiotherapy with an air core light guide.

Authors:  J Lambert; Y Yin; D R McKenzie; S Law; N Suchowerska
Journal:  Phys Med Biol       Date:  2008-05-19       Impact factor: 3.609

6.  A mathematical formalism for hyperspectral, multipoint plastic scintillation detectors.

Authors:  Louis Archambault; François Therriault-Proulx; Sam Beddar; Luc Beaulieu
Journal:  Phys Med Biol       Date:  2012-10-12       Impact factor: 3.609

7.  A depth-dose measuring device using a multichannel scintillating fiber array for electron beam therapy.

Authors:  T Aoyama; S Koyama; M Tsuzaka; H Maekoshi
Journal:  Med Phys       Date:  1997-08       Impact factor: 4.071

8.  Spectral discrimination of Cerenkov radiation in scintillating dosimeters.

Authors:  A M Frelin; J M Fontbonne; G Ban; J Colin; M Labalme; A Batalla; A Isambert; A Vela; T Leroux
Journal:  Med Phys       Date:  2005-09       Impact factor: 4.071

9.  Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements.

Authors:  A S Beddar; T R Mackie; F H Attix
Journal:  Phys Med Biol       Date:  1992-10       Impact factor: 3.609

10.  Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical consideration.

Authors:  A S Beddar; T R Mackie; F H Attix
Journal:  Phys Med Biol       Date:  1992-10       Impact factor: 3.609

View more
  8 in total

1.  On the use of a single-fiber multipoint plastic scintillation detector for 192Ir high-dose-rate brachytherapy.

Authors:  François Therriault-Proulx; Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

Review 2.  In vivo dosimetry: trends and prospects for brachytherapy.

Authors:  G Kertzscher; A Rosenfeld; S Beddar; K Tanderup; J E Cygler
Journal:  Br J Radiol       Date:  2014-07-08       Impact factor: 3.039

3.  On the nature of the light produced within PMMA optical light guides in scintillation fiber-optic dosimetry.

Authors:  François Therriault-Proulx; Luc Beaulieu; Louis Archambault; Sam Beddar
Journal:  Phys Med Biol       Date:  2013-03-08       Impact factor: 3.609

4.  A method to correct for temperature dependence and measure simultaneously dose and temperature using a plastic scintillation detector.

Authors:  Francois Therriault-Proulx; Landon Wootton; Sam Beddar
Journal:  Phys Med Biol       Date:  2015-09-25       Impact factor: 3.609

5.  Temperature dependence of BCF plastic scintillation detectors.

Authors:  Landon Wootton; Sam Beddar
Journal:  Phys Med Biol       Date:  2013-04-11       Impact factor: 3.609

Review 6.  Optical fibre sensors: their role in in vivo dosimetry for prostate cancer radiotherapy.

Authors:  P Woulfe; F J Sullivan; S O'Keeffe
Journal:  Cancer Nanotechnol       Date:  2016-10-18

7.  Toward 3D dose verification of an electronic brachytherapy source with a plastic scintillation detector.

Authors:  Peter Georgi; Gustavo Kertzscher; Lars Nyvang; Jaroslav Šolc; Thorsten Schneider; Kari Tanderup; Jacob Graversen Johansen
Journal:  Med Phys       Date:  2022-03-03       Impact factor: 4.506

8.  Characterization of a Low-Cost Plastic Fiber Array Detector for Proton Beam Dosimetry.

Authors:  Cigdem Ozkan Loch; Michael Alexander Eichenberger; Michele Togno; Simon Pascal Zinsli; Martina Egloff; Angela Papa; Rasmus Ischebeck; Antony John Lomax; Peter Peier; Sairos Safai
Journal:  Sensors (Basel)       Date:  2020-10-09       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.