Fast 2D phantom dosimetry for scanning proton beams.

S N Boon1, P van Luijk, J M Schippers, H Meertens, J M Denis, S Vynckier, J Medin, E Grusell.   

Abstract

A quality control system especially designed for dosimetry in scanning proton beams has been designed and tested. The system consists of a scintillating screen (Gd2O2S:Tb), mounted at the beam-exit side of a phantom, and observed by a low noise CCD camera with a long integration time. The purpose of the instrument is to make a fast and accurate two-dimensional image of the dose distribution at the screen position in the phantom. The linearity of the signal with the dose, the noise in the signal, the influence of the ionization density on the signal, and the influence of the field size on the signal have been investigated. The spatial resolution is 1.3 mm (1 s.d.), which is sufficiently smaller than typical penumbras in dose distributions. The measured yield depends linearly on the dose and agrees within 5% with the calculations. In the images a signal to noise ration (signal/1 s.d.) of 10(2) has been found, which is in the same order of magnitude as expected from the calculations. At locations in the dose distribution possessing a strong contribution of high ionization densities (i.e., in the Bragg peak), we found some quenching of the light output, which can be described well by existing models if the beam characteristics are known. For clinically used beam characteristics such as a Spread Out Bragg peak, there is at most 8% deviation from the NACP ionization chamber measurements. The conclusion is that this instrument is a useful tool for quick and reliable quality control of proton beams. The long integration-time capabilities of the system make it worthwhile to investigate its applicability in scanning proton beams and other dynamic treatment modalities.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9571612     DOI: 10.1118/1.598221

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  13 in total

1.  Verification of proton range, position, and intensity in IMPT with a 3D liquid scintillator detector system.

Authors:  L Archambault; F Poenisch; N Sahoo; D Robertson; A Lee; M T Gillin; R Mohan; S Beddar
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

2.  Transient noise characterization and filtration in CCD cameras exposed to stray radiation from a medical linear accelerator.

Authors:  Louis Archambault; Tina Marie Briere; Sam Beddar
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

3.  Liquid scintillator for 2D dosimetry for high-energy photon beams.

Authors:  Falk Pönisch; Louis Archambault; Tina Marie Briere; Narayan Sahoo; Radhe Mohan; Sam Beddar; Michael T Gillin
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

4.  Exploration of the potential of liquid scintillators for real-time 3D dosimetry of intensity modulated proton beams.

Authors:  Sam Beddar; Louis Archambault; Narayan Sahoo; Falk Poenisch; George T Chen; Michael T Gillin; Radhe Mohan
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

5.  Fast range measurement of spot scanning proton beams using a volumetric liquid scintillator detector.

Authors:  CheukKai Hui; Daniel Robertson; Fahed Alsanea; Sam Beddar
Journal:  Biomed Phys Eng Express       Date:  2015-07-30

6.  Polyenergetic Data Acquisition Using a Video-Scintillator Detector for Scanned Proton Beams.

Authors:  John G Eley; Daniel R Strauss; Ulrich W Langner
Journal:  Int J Part Ther       Date:  2017-03-14

7.  Sparing the region of the salivary gland containing stem cells preserves saliva production after radiotherapy for head and neck cancer.

Authors:  Peter van Luijk; Sarah Pringle; Joseph O Deasy; Vitali V Moiseenko; Hette Faber; Allan Hovan; Mirjam Baanstra; Hans P van der Laan; Roel G J Kierkels; Arjen van der Schaaf; Max J Witjes; Jacobus M Schippers; Sytze Brandenburg; Johannes A Langendijk; Jonn Wu; Robert P Coppes
Journal:  Sci Transl Med       Date:  2015-09-16       Impact factor: 17.956

8.  3D reconstruction of scintillation light emission from proton pencil beams using limited viewing angles-a simulation study.

Authors:  CheukKai Hui; Daniel Robertson; Sam Beddar
Journal:  Phys Med Biol       Date:  2014-07-23       Impact factor: 3.609

9.  Investigation of the feasibility of a simple method for verifying the motion of a binary multileaf collimator synchronized with the rotation of the gantry for helical tomotherapy.

Authors:  Masatoshi Hashimoto; Masahiro Uematsu; Makiko Ito; Yukihiro Hama; Takayuki Inomata; Masahiro Fujii; Teiji Nishio; Naoki Nakamura; Keiichi Nakagawa
Journal:  J Appl Clin Med Phys       Date:  2012-01-05       Impact factor: 2.102

10.  A simple microscopy setup for visualizing cellular responses to DNA damage at particle accelerator facilities.

Authors:  Haibin Qian; Ron A Hoebe; Michel R Faas; Marc Jan van Goethem; Emiel R van der Graaf; Christoph Meyer; Harry Kiewiet; Sytze Brandenburg; Przemek M Krawczyk
Journal:  Sci Rep       Date:  2021-07-15       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.