Plastic scintillation dosimetry: optimal selection of scintillating fibers and scintillators.

Louis Archambault1, Jean Arsenault, Luc Gingras, A Sam Beddar, René Roy, Luc Beaulieu.   

Abstract

Scintillation dosimetry is a promising avenue for evaluating dose patterns delivered by intensity-modulated radiation therapy plans or for the small fields involved in stereotactic radiosurgery. However, the increase in signal has been the goal for many authors. In this paper, a comparison is made between plastic scintillating fibers and plastic scintillator. The collection of scintillation light was measured experimentally for four commercial models of scintillating fibers (BCF-12, BCF-60, SCSF-78, SCSF-3HF) and two models of plastic scintillators (BC-400, BC-408). The emission spectra of all six scintillators were obtained by using an optical spectrum analyzer and they were compared with theoretical behavior. For scintillation in the blue region, the signal intensity of a singly clad scintillating fiber (BCF-12) was 120% of that of the plastic scintillator (BC-400). For the multiclad fiber (SCSF-78), the signal reached 144% of that of the plastic scintillator. The intensity of the green scintillating fibers was lower than that of the plastic scintillator: 47% for the singly clad fiber (BCF-60) and 77% for the multiclad fiber (SCSF-3HF). The collected light was studied as a function of the scintillator length and radius for a cylindrical probe. We found that symmetric detectors with nearly the same spatial resolution in each direction (2 mm in diameter by 3 mm in length) could be made with a signal equivalent to those of the more commonly used asymmetric scintillators. With augmentation of the signal-to-noise ratio in consideration, this paper presents a series of comparisons that should provide insight into selection of a scintillator type and volume for development of a medical dosimeter.

Mesh:

Substances:

Year:  2005        PMID: 16121582     DOI: 10.1118/1.1943807

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  Transient noise characterization and filtration in CCD cameras exposed to stray radiation from a medical linear accelerator.

Authors:  Louis Archambault; Tina Marie Briere; Sam Beddar
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

2.  Characterizing the response of miniature scintillation detectors when irradiated with proton beams.

Authors:  Louis Archambault; Jerimy C Polf; Luc Beaulieu; Sam Beddar
Journal:  Phys Med Biol       Date:  2008-03-10       Impact factor: 3.609

Review 3.  Optical and x-ray technology synergies enabling diagnostic and therapeutic applications in medicine.

Authors:  Brian W Pogue; Brian C Wilson
Journal:  J Biomed Opt       Date:  2018-10       Impact factor: 3.170

4.  Toward a real-time in vivo dosimetry system using plastic scintillation detectors.

Authors:  Louis Archambault; Tina M Briere; Falk Pönisch; Luc Beaulieu; Deborah A Kuban; Andrew Lee; Sam Beddar
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-03-16       Impact factor: 7.038

5.  A method to correct for temperature dependence and measure simultaneously dose and temperature using a plastic scintillation detector.

Authors:  Francois Therriault-Proulx; Landon Wootton; Sam Beddar
Journal:  Phys Med Biol       Date:  2015-09-25       Impact factor: 3.609

6.  Preliminary evaluation of the dosimetric accuracy of the in vivo plastic scintillation detector OARtrac system for prostate cancer treatments.

Authors:  Slade J Klawikowski; Clint Zeringue; Landon S Wootton; Geoffrey S Ibbott; Sam Beddar
Journal:  Phys Med Biol       Date:  2014-04-15       Impact factor: 3.609

7.  Europium- and lithium-doped yttrium oxide nanocrystals that provide a linear emissive response with X-ray radiation exposure.

Authors:  Ian N Stanton; Matthew D Belley; Giao Nguyen; Anna Rodrigues; Yifan Li; David G Kirsch; Terry T Yoshizumi; Michael J Therien
Journal:  Nanoscale       Date:  2014-05-21       Impact factor: 7.790

8.  Temperature dependence of BCF plastic scintillation detectors.

Authors:  Landon Wootton; Sam Beddar
Journal:  Phys Med Biol       Date:  2013-04-11       Impact factor: 3.609

9.  Response to Re: Estimating and reducing dose received by cardiac devices for patients undergoing radiotherapy.

Authors:  Louis Archambault; Nicolas Varfalvy; Alexandra Bourgouin
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

10.  Characterization of an inorganic scintillator for small-field dosimetry in MR-guided radiotherapy.

Authors:  Davide Cusumano; Lorenzo Placidi; Emiliano D'Agostino; Luca Boldrini; Sebastiano Menna; Vincenzo Valentini; Marco De Spirito; Luigi Azario
Journal:  J Appl Clin Med Phys       Date:  2020-08-25       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.