Literature DB >> 18955172

Application of three-class ROC analysis to task-based image quality assessment of simultaneous dual-isotope myocardial perfusion SPECT (MPS).

Xin He1, Xiyun Song, Eric C Frey.   

Abstract

The diagnosis of cardiac disease using dual-isotope myocardial perfusion SPECT (MPS) is based on the defect status in both stress and rest images, and can be modeled as a three-class task of classifying patients as having no, reversible, or fixed perfusion defects. Simultaneous acquisition protocols for dual-isotope MPS imaging have gained much interest due to their advantages including perfect registration of the (201)Tl and (99m)Tc images in space and time, increased patient comfort, and higher clinical throughput. As a result of simultaneous acquisition, however, crosstalk contamination, where photons emitted by one isotope contribute to the image of the other isotope, degrades image quality. Minimizing the crosstalk is important in obtaining the best possible image quality. One way to minimize the crosstalk is to optimize the injected activity of the two isotopes by considering the three-class nature of the diagnostic problem. To effectively do so, we have previously developed a three-class receiver operating characteristic (ROC) analysis methodology that extends and unifies the decision theoretic, linear discriminant analysis, and psychophysical foundations of binary ROC analysis in a three-class paradigm. In this work, we applied the proposed three-class ROC methodology to the assessment of the image quality of simultaneous dual-isotope MPS imaging techniques and the determination of the optimal injected activity combination. In addition to this application, the rapid development of diagnostic imaging techniques has produced an increasing number of clinical diagnostic tasks that involve not only disease detection, but also disease characterization and are thus multiclass tasks. This paper provides a practical example of the application of the proposed three-class ROC analysis methodology to medical problems.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18955172      PMCID: PMC2668219          DOI: 10.1109/TMI.2008.928921

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  28 in total

1.  Comparing three-class diagnostic tests by three-way ROC analysis.

Authors:  S Dreiseitl; L Ohno-Machado; M Binder
Journal:  Med Decis Making       Date:  2000 Jul-Sep       Impact factor: 2.583

2.  Application of task-based measures of image quality to optimization and evaluation of three-dimensional reconstruction-based compensation methods in myocardial perfusion SPECT.

Authors:  Eric C Frey; Karen L Gilland; Benjamin M W Tsui
Journal:  IEEE Trans Med Imaging       Date:  2002-09       Impact factor: 10.048

3.  The hypervolume under the ROC hypersurface of "near-guessing" and "near-perfect" observers in N-class classification tasks.

Authors:  Darrin C Edwards; Charles E Metz; Robert M Nishikawa
Journal:  IEEE Trans Med Imaging       Date:  2005-03       Impact factor: 10.048

4.  Fast modelling of the collimator-detector response in Monte Carlo simulation of SPECT imaging using the angular response function.

Authors:  X Song; W P Segars; Y Du; B M W Tsui; E C Frey
Journal:  Phys Med Biol       Date:  2005-04-06       Impact factor: 3.609

5.  The meaning and use of the volume under a three-class ROC surface (VUS).

Authors:  Xin He; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2008-05       Impact factor: 10.048

6.  Three-way ROCs.

Authors:  D Mossman
Journal:  Med Decis Making       Date:  1999 Jan-Mar       Impact factor: 2.583

7.  Multiple-Event Forced-Choice Tasks in the Theory of Signal Detectability

Authors: 
Journal:  J Math Psychol       Date:  1996-09       Impact factor: 2.223

8.  Three-class ROC analysis--the equal error utility assumption and the optimality of three-class ROC surface using the ideal observer.

Authors:  Xin He; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2006-08       Impact factor: 10.048

9.  Primer on certain elements of medical decision making.

Authors:  B J McNeil; E Keller; S J Adelstein
Journal:  N Engl J Med       Date:  1975-07-31       Impact factor: 91.245

10.  The meaning and use of the area under a receiver operating characteristic (ROC) curve.

Authors:  J A Hanley; B J McNeil
Journal:  Radiology       Date:  1982-04       Impact factor: 11.105

View more
  8 in total

1.  Validation of Monte Carlo estimates of three-class ideal observer operating points for normal data.

Authors:  Darrin C Edwards
Journal:  Acad Radiol       Date:  2013-07       Impact factor: 3.173

2.  Comparison of simultaneous and sequential SPECT imaging for discrimination tasks in assessment of cardiac defects.

Authors:  C M Trott; J Ouyang; G El Fakhri
Journal:  Phys Med Biol       Date:  2010-11-03       Impact factor: 3.609

3.  Assessment of cardiac single-photon emission computed tomography performance using a scanning linear observer.

Authors:  Chih-Jie Lee; Matthew A Kupinski; Lana Volokh
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

4.  Optimization of energy window and evaluation of scatter compensation methods in myocardial perfusion SPECT using the ideal observer with and without model mismatch and an anthropomorphic model observer.

Authors:  Michael Ghaly; Jonathan M Links; Eric Frey
Journal:  J Med Imaging (Bellingham)       Date:  2015-01

5.  Optimization and comparison of simultaneous and separate acquisition protocols for dual isotope myocardial perfusion SPECT.

Authors:  Michael Ghaly; Jonathan M Links; Eric C Frey
Journal:  Phys Med Biol       Date:  2015-06-17       Impact factor: 3.609

6.  Regularized image reconstruction algorithms for dual-isotope myocardial perfusion SPECT (MPS) imaging using a cross-tracer prior.

Authors:  Xin He; Lishui Cheng; Jeffrey A Fessler; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2010-10-14       Impact factor: 10.048

7.  Simultaneous Tc-99m/I-123 dual-radionuclide myocardial perfusion/innervation imaging using Siemens IQ-SPECT with SMARTZOOM collimator.

Authors:  Yong Du; Manojeet Bhattacharya; Eric C Frey
Journal:  Phys Med Biol       Date:  2014-05-13       Impact factor: 3.609

8.  Evaluation of simultaneous 201Tl/99mTc dual-isotope cardiac SPECT imaging with model-based crosstalk compensation using canine studies.

Authors:  Y Du; J M Links; L Becker; A F DiPaula; T Frank; K H Schuleri; A C Lardo; E C Frey
Journal:  J Nucl Cardiol       Date:  2013-12-24       Impact factor: 5.952

  8 in total