Literature DB >> 26029730

Optimization of energy window and evaluation of scatter compensation methods in myocardial perfusion SPECT using the ideal observer with and without model mismatch and an anthropomorphic model observer.

Michael Ghaly1, Jonathan M Links2, Eric Frey1.   

Abstract

We used the ideal observer (IO) and IO with model mismatch (IO-MM) applied in the projection domain and an anthropomorphic channelized Hotelling observer (CHO) applied to reconstructed images to optimize the acquisition energy window width and to evaluate various scatter compensation methods in the context of a myocardial perfusion single-photon emission computed tomography (SPECT) defect detection task. The IO has perfect knowledge of the image formation process and thus reflects the performance with perfect compensation for image-degrading factors. Thus, using the IO to optimize imaging systems could lead to suboptimal parameters compared with those optimized for humans interpreting SPECT images reconstructed with imperfect or no compensation. The IO-MM allows incorporating imperfect system models into the IO optimization process. We found that with near-perfect scatter compensation, the optimal energy window for the IO and CHO was similar; in its absence, the IO-MM gave a better prediction of the optimal energy window for the CHO using different scatter compensation methods. These data suggest that the IO-MM may be useful for projectiondomain optimization when MM is significant and that the IO is useful when followed by reconstruction with good models of the image formation process.

Entities:  

Keywords:  anthropomorphic observer; model mismatch; scatter compensation; single-photon emission computed tomography; the ideal observer

Year:  2015        PMID: 26029730      PMCID: PMC4447606          DOI: 10.1117/1.JMI.2.1.015502

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  30 in total

1.  Receiver operating characteristic evaluation of iterative reconstruction with attenuation correction in 99mTc-sestamibi myocardial SPECT images.

Authors:  K J LaCroix; B M Tsui; E C Frey; R J Jaszczak
Journal:  J Nucl Med       Date:  2000-03       Impact factor: 10.057

2.  Fast modelling of the collimator-detector response in Monte Carlo simulation of SPECT imaging using the angular response function.

Authors:  X Song; W P Segars; Y Du; B M W Tsui; E C Frey
Journal:  Phys Med Biol       Date:  2005-04-06       Impact factor: 3.609

3.  Evaluation of 3D Monte Carlo-based scatter correction for 99mTc cardiac perfusion SPECT.

Authors:  Jianbin Xiao; Tim C de Wit; Steven G Staelens; Freek J Beekman
Journal:  J Nucl Med       Date:  2006-10       Impact factor: 10.057

4.  Development and evaluation of an improved quantitative (90)Y bremsstrahlung SPECT method.

Authors:  Xing Rong; Yong Du; Michael Ljungberg; Erwann Rault; Stefaan Vandenberghe; Eric C Frey
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

5.  Statistical comparison of two ROC-curve estimates obtained from partially-paired datasets.

Authors:  C E Metz; B A Herman; C A Roe
Journal:  Med Decis Making       Date:  1998 Jan-Mar       Impact factor: 2.583

6.  Addition of a channel mechanism to the ideal-observer model.

Authors:  K J Myers; H H Barrett
Journal:  J Opt Soc Am A       Date:  1987-12       Impact factor: 2.129

7.  Improved SPECT quantification using compensation for scattered photons.

Authors:  R J Jaszczak; K L Greer; C E Floyd; C C Harris; R E Coleman
Journal:  J Nucl Med       Date:  1984-08       Impact factor: 10.057

8.  Simultaneous technetium-99m/thallium-201 SPECT imaging with model-based compensation for cross-contaminating effects.

Authors:  D J Kadrmas; E C Frey; B M Tsui
Journal:  Phys Med Biol       Date:  1999-07       Impact factor: 3.609

9.  Application of three-class ROC analysis to task-based image quality assessment of simultaneous dual-isotope myocardial perfusion SPECT (MPS).

Authors:  Xin He; Xiyun Song; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2008-11       Impact factor: 10.048

10.  Assessment of scatter compensation strategies for (67)Ga SPECT using numerical observers and human LROC studies.

Authors:  Troy H Farncombe; Howard C Gifford; Manoj V Narayanan; P Hendrik Pretorius; Eric C Frey; Michael A King
Journal:  J Nucl Med       Date:  2004-05       Impact factor: 10.057

View more
  8 in total

1.  Factors affecting the normality of channel outputs of channelized model observers: an investigation using realistic myocardial perfusion SPECT images.

Authors:  Fatma E A Elshahaby; Michael Ghaly; Abhinav K Jha; Eric C Frey
Journal:  J Med Imaging (Bellingham)       Date:  2016-01-28

2.  A comparison of resampling schemes for estimating model observer performance with small ensembles.

Authors:  Fatma E A Elshahaby; Abhinav K Jha; Michael Ghaly; Eric C Frey
Journal:  Phys Med Biol       Date:  2017-08-22       Impact factor: 3.609

3.  Collimator optimization and collimator-detector response compensation in myocardial perfusion SPECT using the ideal observer with and without model mismatch and an anthropomorphic model observer.

Authors:  Michael Ghaly; Jonathan M Links; Eric C Frey
Journal:  Phys Med Biol       Date:  2016-02-19       Impact factor: 3.609

4.  Collimator optimization in myocardial perfusion SPECT using the ideal observer and realistic background variability for lesion detection and joint detection and localization tasks.

Authors:  Michael Ghaly; Yong Du; Jonathan M Links; Eric C Frey
Journal:  Phys Med Biol       Date:  2016-02-19       Impact factor: 3.609

5.  Optimization and comparison of simultaneous and separate acquisition protocols for dual isotope myocardial perfusion SPECT.

Authors:  Michael Ghaly; Jonathan M Links; Eric C Frey
Journal:  Phys Med Biol       Date:  2015-06-17       Impact factor: 3.609

6.  Use of Sub-Ensembles and Multi-Template Observers to Evaluate Detection Task Performance for Data That are Not Multivariate Normal.

Authors:  Xin Li; Abhinav K Jha; Michael Ghaly; Fatma E A Elshahaby; Jonathan M Links; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2016-12-22       Impact factor: 10.048

7.  Assessment of Four Scatter Correction Methods in In-111 SPECT Imaging: A Simulation Study.

Authors:  Mahsa Noori-Asl
Journal:  J Med Phys       Date:  2020-07-20

Review 8.  Virtual clinical trials in medical imaging: a review.

Authors:  Ehsan Abadi; William P Segars; Benjamin M W Tsui; Paul E Kinahan; Nick Bottenus; Alejandro F Frangi; Andrew Maidment; Joseph Lo; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2020-04-11
  8 in total