Literature DB >> 15815096

Fast modelling of the collimator-detector response in Monte Carlo simulation of SPECT imaging using the angular response function.

X Song1, W P Segars, Y Du, B M W Tsui, E C Frey.   

Abstract

Interactions of incident photons with the collimator and detector, including septal penetration, scatter and x-ray fluorescence, are significant sources of image degradation in applications of SPECT including dual isotope imaging and imaging using radioisotopes that emit high- or medium-energy photons. Modelling these interactions using full Monte Carlo (MC) simulations is computationally very demanding. We present a new method based on the use of angular response functions (ARFs). The ARF is a function of the incident photon's direction and energy and represents the probability that a photon will either interact with or pass through the collimator, and be detected at the intersection of the photon's direction vector and the detection plane in an energy window of interest. The ARFs were pre-computed using full MC simulations of point sources that include propagation through the collimator-detector system. We have implemented the ARF method for use in conjunction with the SimSET/PHG MC code to provide fast modelling of both interactions in the patient and in the collimator-detector system. Validation results in the three cases studied show that there was good agreement between the projections generated using the ARF method and those from previously validated full MC simulations, but with hundred to thousand fold reductions in simulation time.

Entities:  

Mesh:

Year:  2005        PMID: 15815096     DOI: 10.1088/0031-9155/50/8/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  28 in total

1.  Convolution-Based Forced Detection Monte Carlo Simulation Incorporating Septal Penetration Modeling.

Authors:  Shaoying Liu; Michael A King; Aaron B Brill; Michael G Stabin; Troy H Farncombe
Journal:  IEEE Trans Nucl Sci       Date:  2008-06       Impact factor: 1.679

2.  Effects of shortened acquisition time on accuracy and precision of quantitative estimates of organ activity.

Authors:  Bin He; Eric C Frey
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

3.  The impact of 3D volume of interest definition on accuracy and precision of activity estimation in quantitative SPECT and planar processing methods.

Authors:  Bin He; Eric C Frey
Journal:  Phys Med Biol       Date:  2010-05-28       Impact factor: 3.609

4.  EQPlanar: a maximum-likelihood method for accurate organ activity estimation from whole body planar projections.

Authors:  N Song; B He; R L Wahl; E C Frey
Journal:  Phys Med Biol       Date:  2011-08-03       Impact factor: 3.609

5.  Comparison of residence time estimation methods for radioimmunotherapy dosimetry and treatment planning--Monte Carlo simulation studies.

Authors:  B He; R L Wahl; Y Du; G Sgouros; H Jacene; I Flinn; E C Frey
Journal:  IEEE Trans Med Imaging       Date:  2008-04       Impact factor: 10.048

6.  Simultaneous Tc-99m/I-123 dual-radionuclide myocardial perfusion/innervation imaging using Siemens IQ-SPECT with SMARTZOOM collimator.

Authors:  Yong Du; Manojeet Bhattacharya; Eric C Frey
Journal:  Phys Med Biol       Date:  2014-05-13       Impact factor: 3.609

7.  In vivo tumor grading of prostate cancer using quantitative 111In-capromab pendetide SPECT/CT.

Authors:  Youngho Seo; Carina Mari Aparici; Matthew R Cooperberg; Badrinath R Konety; Randall A Hawkins
Journal:  J Nucl Med       Date:  2009-12-15       Impact factor: 10.057

8.  Application of three-class ROC analysis to task-based image quality assessment of simultaneous dual-isotope myocardial perfusion SPECT (MPS).

Authors:  Xin He; Xiyun Song; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2008-11       Impact factor: 10.048

9.  Evaluation of quantitative imaging methods for organ activity and residence time estimation using a population of phantoms having realistic variations in anatomy and uptake.

Authors:  Bin He; Yong Du; W Paul Segars; Richard L Wahl; George Sgouros; Heather Jacene; Eric C Frey
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

10.  A detector response function design in pinhole SPECT including geometrical calibration.

Authors:  Z El Bitar; R H Huesman; R Boutchko; Virgile Bekaert; David Brasse; G T Gullberg
Journal:  Phys Med Biol       Date:  2013-03-15       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.