Literature DB >> 26083239

Optimization and comparison of simultaneous and separate acquisition protocols for dual isotope myocardial perfusion SPECT.

Michael Ghaly1, Jonathan M Links, Eric C Frey.   

Abstract

Dual-isotope simultaneous-acquisition (DISA) rest-stress myocardial perfusion SPECT (MPS) protocols offer a number of advantages over separate acquisition. However, crosstalk contamination due to scatter in the patient and interactions in the collimator degrade image quality. Compensation can reduce the effects of crosstalk, but does not entirely eliminate image degradations. Optimizing acquisition parameters could further reduce the impact of crosstalk. In this paper we investigate the optimization of the rest Tl-201 energy window width and relative injected activities using the ideal observer (IO), a realistic digital phantom population and Monte Carlo (MC) simulated Tc-99m and Tl-201 projections as a means to improve image quality. We compared performance on a perfusion defect detection task for Tl-201 acquisition energy window widths varying from 4 to 40 keV centered at 72 keV for a camera with a 9% energy resolution. We also investigated 7 different relative injected activities, defined as the ratio of Tc-99m and Tl-201 activities, while keeping the total effective dose constant at 13.5 mSv. For each energy window and relative injected activity, we computed the IO test statistics using a Markov chain Monte Carlo (MCMC) method for an ensemble of 1,620 triplets of fixed and reversible defect-present, and defect-absent noisy images modeling realistic background variations. The volume under the 3-class receiver operating characteristic (ROC) surface (VUS) was estimated and served as the figure of merit. For simultaneous acquisition, the IO suggested that relative Tc-to-Tl injected activity ratios of 2.6-5 and acquisition energy window widths of 16-22% were optimal. For separate acquisition, we observed a broad range of optimal relative injected activities from 2.6 to 12.1 and acquisition energy window of widths 16-22%. A negative correlation between Tl-201 injected activity and the width of the Tl-201 energy window was observed in these ranges. The results also suggested that DISA methods could potentially provide image quality as good as that obtained with separate acquisition protocols. We compared observer performance for the optimized protocols and the current clinical protocol using separate acquisition. The current clinical protocols provided better performance at a cost of injecting the patient with approximately double the injected activity of Tc-99m and Tl-201, resulting in substantially increased radiation dose.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26083239      PMCID: PMC4685479          DOI: 10.1088/0031-9155/60/13/5083

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  28 in total

1.  Ideal-observer performance under signal and background uncertainty.

Authors:  S Park; M A Kupinski; E Clarkson; H H Barrett
Journal:  Inf Process Med Imaging       Date:  2003-07

2.  Fast modelling of the collimator-detector response in Monte Carlo simulation of SPECT imaging using the angular response function.

Authors:  X Song; W P Segars; Y Du; B M W Tsui; E C Frey
Journal:  Phys Med Biol       Date:  2005-04-06       Impact factor: 3.609

3.  The meaning and use of the volume under a three-class ROC surface (VUS).

Authors:  Xin He; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2008-05       Impact factor: 10.048

4.  Three-class ROC analysis--the equal error utility assumption and the optimality of three-class ROC surface using the ideal observer.

Authors:  Xin He; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2006-08       Impact factor: 10.048

5.  Design of a digital phantom population for myocardial perfusion SPECT imaging research.

Authors:  Michael Ghaly; Yong Du; George S K Fung; Benjamin M W Tsui; Jonathan M Links; Eric Frey
Journal:  Phys Med Biol       Date:  2014-05-19       Impact factor: 3.609

6.  A new dual-isotope convolution cross-talk correction method: a Tl-201/Tc-99m SPECT cardiac phantom study.

Authors:  K Knesaurek
Journal:  Med Phys       Date:  1994-10       Impact factor: 4.071

7.  Simultaneous technetium-99m/thallium-201 SPECT imaging with model-based compensation for cross-contaminating effects.

Authors:  D J Kadrmas; E C Frey; B M Tsui
Journal:  Phys Med Biol       Date:  1999-07       Impact factor: 3.609

8.  Optimization of energy window and evaluation of scatter compensation methods in myocardial perfusion SPECT using the ideal observer with and without model mismatch and an anthropomorphic model observer.

Authors:  Michael Ghaly; Jonathan M Links; Eric Frey
Journal:  J Med Imaging (Bellingham)       Date:  2015-01

9.  Dual-isotope myocardial SPECT in patients with redefined myocardial infarction.

Authors:  Masato Fukushima; Yoshihiko Seino; Shin-ichiro Kumita; Hidenobu Nakajo; Keiichi Cho; Teruo Takano
Journal:  Int J Cardiol       Date:  2005-09-30       Impact factor: 4.164

10.  Application of three-class ROC analysis to task-based image quality assessment of simultaneous dual-isotope myocardial perfusion SPECT (MPS).

Authors:  Xin He; Xiyun Song; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2008-11       Impact factor: 10.048

View more
  1 in total

1.  Use of Sub-Ensembles and Multi-Template Observers to Evaluate Detection Task Performance for Data That are Not Multivariate Normal.

Authors:  Xin Li; Abhinav K Jha; Michael Ghaly; Fatma E A Elshahaby; Jonathan M Links; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2016-12-22       Impact factor: 10.048

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.