Geometric calibration for a dual tube/detector micro-CT system.

Samuel M Johnston1, G Allan Johnson, Cristian T Badea.   

Abstract

The authors describe a dual tube/detector micro-computed tomography (micro-CT) system that has the potential to improve temporal resolution and material contrast in small animal imaging studies. To realize this potential, it is necessary to precisely calibrate the geometry of a dual micro-CT system to allow the combination of projection data acquired with each individual tube/detector in a single reconstructed image. The authors present a geometric calibration technique that uses multiple projection images acquired with the two imaging chains while rotating a phantom containing a vertical array of regularly spaced metallic beads. The individual geometries of the imaging chains are estimated from the phantom projection images using analytical methods followed by a refinement procedure based on nonlinear optimization. The geometric parameters are used to create the cone beam projection matrices required by the reconstruction process for each imaging chain. Next, a transformation between the two projection matrices is found that allows the combination of projection data in a single reconstructed image. The authors describe this technique, test it with a series of computer simulations, and then apply it to data collected from their dual tube/detector micro-CT system. The results demonstrate that the proposed technique is accurate, robust, and produces images free of misalignment artifacts.

Mesh:

Substances:

Year:  2008        PMID: 18561657      PMCID: PMC2809730          DOI: 10.1118/1.2900000

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  20 in total

1.  Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: image-based correction of gantry motion nonidealities.

Authors:  R Fahrig; D W Holdsworth
Journal:  Med Phys       Date:  2000-01       Impact factor: 4.071

2.  Implementation of a cone-beam reconstruction algorithm for the single-circle source orbit with embedded misalignment correction using homogeneous coordinates.

Authors:  M Karolczak; S Schaller; K Engelke; A Lutz; U Taubenreuther; K Wiesent; W Kalender
Journal:  Med Phys       Date:  2001-10       Impact factor: 4.071

Review 3.  A review of high-resolution X-ray computed tomography and other imaging modalities for small animal research.

Authors:  M J Paulus; S S Gleason; M E Easterly; C J Foltz
Journal:  Lab Anim (NY)       Date:  2001-03       Impact factor: 12.625

4.  Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography.

Authors:  F Noo; R Clackdoyle; C Mennessier; T A White; T J Roney
Journal:  Phys Med Biol       Date:  2000-11       Impact factor: 3.609

5.  Cone-beam reprojection using projection-matrices.

Authors:  Ramesh R Galigekere; Karl Wiesent; David W Holdsworth
Journal:  IEEE Trans Med Imaging       Date:  2003-10       Impact factor: 10.048

6.  Geometric misalignment and calibration in cone-beam tomography.

Authors:  Lorenz von Smekal; Marc Kachelriess; Elizaveta Stepina; Willi A Kalender
Journal:  Med Phys       Date:  2004-12       Impact factor: 4.071

7.  Empirical dual energy calibration (EDEC) for cone-beam computed tomography.

Authors:  Philip Stenner; Timo Berkus; Marc Kachelriess
Journal:  Med Phys       Date:  2007-09       Impact factor: 4.071

8.  Astigmatic single photon emission computed tomography imaging with a displaced center of rotation.

Authors:  H Wang; M F Smith; C D Stone; R J Jaszczak
Journal:  Med Phys       Date:  1998-08       Impact factor: 4.071

9.  Determination of both mechanical and electronic shifts in cone beam SPECT.

Authors:  J Li; R J Jaszczak; H Wang; K L Greer; R E Coleman
Journal:  Phys Med Biol       Date:  1993-06       Impact factor: 3.609

10.  Geometrical calibration of X-ray imaging chains for three-dimensional reconstruction.

Authors:  A Rougée; C Picard; C Ponchut; Y Trousset
Journal:  Comput Med Imaging Graph       Date:  1993 Jul-Oct       Impact factor: 4.790

View more
  15 in total

1.  A dual micro-CT system for small animal imaging.

Authors:  C T Badea; S Johnston; B Johnson; M Lin; L W Hedlund; G Allan Johnson
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008-04-18

2.  Lung imaging in rodents using dual energy micro-CT.

Authors:  C T Badea; X Guo; D Clark; S M Johnston; C Marshall; C Piantadosi
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-04-03

3.  Lung perfusion imaging in small animals using 4D micro-CT at heartbeat temporal resolution.

Authors:  Cristian T Badea; Samuel M Johnston; Ergys Subashi; Yi Qi; Laurence W Hedlund; G Allan Johnson
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

4.  Dual-energy micro-CT of the rodent lung.

Authors:  C T Badea; X Guo; D Clark; S M Johnston; C D Marshall; C A Piantadosi
Journal:  Am J Physiol Lung Cell Mol Physiol       Date:  2012-03-16       Impact factor: 5.464

5.  Dual source hybrid spectral micro-CT using an energy-integrating and a photon-counting detector.

Authors:  M D Holbrook; D P Clark; C T Badea
Journal:  Phys Med Biol       Date:  2020-10-21       Impact factor: 3.609

6.  4D micro-CT for cardiac and perfusion applications with view under sampling.

Authors:  Cristian T Badea; Samuel M Johnston; Yi Qi; G Allan Johnson
Journal:  Phys Med Biol       Date:  2011-05-10       Impact factor: 3.609

7.  Prospective-gated cardiac micro-CT imaging of free-breathing mice using carbon nanotube field emission x-ray.

Authors:  Guohua Cao; Laurel M Burk; Yueh Z Lee; Xiomara Calderon-Colon; Shabana Sultana; Jianping Lu; Otto Zhou
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

8.  In vivo characterization of tumor vasculature using iodine and gold nanoparticles and dual energy micro-CT.

Authors:  Darin P Clark; Ketan Ghaghada; Everett J Moding; David G Kirsch; Cristian T Badea
Journal:  Phys Med Biol       Date:  2013-02-19       Impact factor: 3.609

9.  Three-dimensional reconstruction in free-space whole-body fluorescence tomography of mice using optically reconstructed surface and atlas anatomy.

Authors:  Xiaofeng Zhang; Cristian T Badea; G Allan Johnson
Journal:  J Biomed Opt       Date:  2009 Nov-Dec       Impact factor: 3.170

10.  Dual-energy computed tomography imaging of atherosclerotic plaques in a mouse model using a liposomal-iodine nanoparticle contrast agent.

Authors:  Rohan Bhavane; Cristian Badea; Ketan B Ghaghada; Darin Clark; Deborah Vela; Anoosha Moturu; Akshaya Annapragada; G Allan Johnson; James T Willerson; Ananth Annapragada
Journal:  Circ Cardiovasc Imaging       Date:  2013-01-24       Impact factor: 7.792

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.