Cone-beam reprojection using projection-matrices.

Ramesh R Galigekere1, Karl Wiesent, David W Holdsworth.   

Abstract

This paper addresses reprojection of three-dimensional (3-D) reconstructions obtained from cone-beam scans using a C-arm imaging equipment assisted by a pose-determining system. The emphasis is on reprojecting without decomposing the estimated projection matrix (P-matrix) associated with a pose. Both voxel- and ray-driven methods are considered. The voxel-driven reprojector follows the algorithm for backprojection using a P-matrix. The ray-driven reprojector is derived by extracting from the P-matrix the equation of the line joining a detector-pixel and the X-ray source position. This reprojector can be modified to a ray-driven backprojector. When the geometry is specified explicitly in terms of the physical parameters of the imaging system, the projection matrices can be constructed. The resulting "projection-matrix method" is advantageous, especially when the scanning trajectory is irregular. The algorithms presented are useful in iterative methods of image reconstruction and enhancement procedures, apart from their well-known role in visualization and volume rendering. Reprojections of 3-D patient data compare favorably with the original X-ray projections obtained from a prototype C-arm system. The algorithms for reprojection can be modified to compute perspective maximum intensity projection.

Entities:  

Mesh:

Year:  2003        PMID: 14552575     DOI: 10.1109/TMI.2003.817787

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  17 in total

1.  Markov random field modeling for three-dimensional reconstruction of the left ventricle in cardiac angiography.

Authors:  Rubén Medina; Mireille Garreau; Javier Toro; Hervé L Breton; Jean-Louis Coatrieux; Diego Jugo
Journal:  IEEE Trans Med Imaging       Date:  2006-08       Impact factor: 10.048

2.  Grating-based phase contrast tomosynthesis imaging: proof-of-concept experimental studies.

Authors:  Ke Li; Yongshuai Ge; John Garrett; Nicholas Bevins; Joseph Zambelli; Guang-Hong Chen
Journal:  Med Phys       Date:  2014-01       Impact factor: 4.071

3.  Geometric calibration for a dual tube/detector micro-CT system.

Authors:  Samuel M Johnston; G Allan Johnson; Cristian T Badea
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

4.  Tomosynthesis via Total Variation Minimization Reconstruction and Prior Image Constrained Compressed Sensing (PICCS) on a C-arm System.

Authors:  Brian Nett; Jie Tang; Shuai Leng; Guang-Hong Chen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008-03-18

5.  Dual resolution cone beam breast CT: a feasibility study.

Authors:  Lingyun Chen; Youtao Shen; Chao-Jen Lai; Tao Han; Yuncheng Zhong; Shuaiping Ge; Xinming Liu; Tianpeng Wang; Wei T Yang; Gary J Whitman; Chris C Shaw
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

6.  Automatic fusion of lateral cephalograms and digital volume tomography data-perspective for combining two modalities in the future.

Authors:  S Sauppe; C Abkai; J Hourfar; B Ludwig; J Ulrici; E Hell
Journal:  Dentomaxillofac Radiol       Date:  2015-07-24       Impact factor: 2.419

7.  Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction.

Authors:  Adam S Wang; J Webster Stayman; Yoshito Otake; Gerhard Kleinszig; Sebastian Vogt; Gary L Gallia; A Jay Khanna; Jeffrey H Siewerdsen
Journal:  Phys Med Biol       Date:  2014-02-07       Impact factor: 3.609

8.  3D forward and back-projection for X-ray CT using separable footprints.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

9.  Low-dose preview for patient-specific, task-specific technique selection in cone-beam CT.

Authors:  Adam S Wang; J Webster Stayman; Yoshito Otake; Sebastian Vogt; Gerhard Kleinszig; A Jay Khanna; Gary L Gallia; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

10.  4D interventional device reconstruction from biplane fluoroscopy.

Authors:  Martin Wagner; Sebastian Schafer; Charles Strother; Charles Mistretta
Journal:  Med Phys       Date:  2016-03       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.