4D micro-CT for cardiac and perfusion applications with view under sampling.

Cristian T Badea1, Samuel M Johnston, Yi Qi, G Allan Johnson.   

Abstract

Micro-CT is commonly used in preclinical studies to provide anatomical information. There is growing interest in obtaining functional measurements from 4D micro-CT. We report here strategies for 4D micro-CT with a focus on two applications: (i) cardiac imaging based on retrospective gating and (ii) pulmonary perfusion using multiple contrast injections/rotations paradigm. A dual source micro-CT system is used for image acquisition with a sampling rate of 20 projections per second. The cardiac micro-CT protocol involves the use of a liposomal blood pool contrast agent. Fast scanning of free breathing mice is achieved using retrospective gating. The ECG and respiratory signals are used to sort projections into ten cardiac phases. The pulmonary perfusion protocol uses a conventional contrast agent (Isovue 370) delivered by a micro-injector in four injections separated by 2 min intervals to allow for clearance. Each injection is synchronized with the rotation of the animal, and each of the four rotations is started with an angular offset of 22.5 from the starting angle of the previous rotation. Both cardiac and perfusion protocols result in an irregular angular distribution of projections that causes significant streaking artifacts in reconstructions when using traditional filtered backprojection (FBP) algorithms. The reconstruction involves the use of the point spread function of the micro-CT system for each time point, and the analysis of the distribution of the reconstructed data in the Fourier domain. This enables us to correct for angular inconsistencies via deconvolution and identify regions where data is missing. The missing regions are filled with data from a high quality but temporally averaged prior image reconstructed with all available projections. Simulations indicate that deconvolution successfully removes the streaking artifacts while preserving temporal information. 4D cardiac micro-CT in a mouse was performed with adequate image quality at isotropic voxel size of 88 µm and 10 ms temporal resolution. 4D pulmonary perfusion images were obtained in a mouse at 176 µm and 687 ms temporal resolution. Compared with FBP reconstruction, the streak reduction ratio is 70% and the contrast to noise ratio is 2.5 times greater in the deconvolved images. The radiation dose associated with the proposed methods is in the range of a typical micro-CT dose (0.17 Gy for the cardiac study and 0.21 Gy for the perfusion study). The low dose 4D micro-CT imaging presented here can be applied in high-throughput longitudinal studies in a wide range of applications, including drug safety and cardiopulmonary phenotyping.

Entities:  

Mesh:

Year:  2011        PMID: 21558587      PMCID: PMC3180888          DOI: 10.1088/0031-9155/56/11/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  25 in total

1.  Techniques to alleviate the effects of view aliasing artifacts in computed tomography.

Authors:  R R Galigekere; K Wiesent; D W Holdsworth
Journal:  Med Phys       Date:  1999-06       Impact factor: 4.071

2.  Tomographic digital subtraction angiography for lung perfusion estimation in rodents.

Authors:  Cristian T Badea; Laurence W Hedlund; Ming De Lin; Julie S Boslego Mackel; Ehsan Samei; G Allan Johnson
Journal:  Med Phys       Date:  2007-05       Impact factor: 4.071

3.  Left ventricle volume measurements in cardiac micro-CT: the impact of radiation dose and contrast agent.

Authors:  Cristian T Badea; Arthur W Wetzel; Nilesh Mistry; Stuart Pomerantz; Demian Nave; G Allan Johnson
Journal:  Comput Med Imaging Graph       Date:  2008-04       Impact factor: 4.790

4.  Image restoration by Wiener deconvolution in limited-view computed tomography.

Authors:  A P Dhawan; R M Rangayyan; R Gordon
Journal:  Appl Opt       Date:  1985-12-01       Impact factor: 1.980

5.  Gating in small-animal cardio-thoracic CT.

Authors:  Soenke H Bartling; Jan Kuntz; Wolfhard Semmler
Journal:  Methods       Date:  2009-08-03       Impact factor: 3.608

6.  Perfusion measurements by micro-CT using prior image constrained compressed sensing (PICCS): initial phantom results.

Authors:  Brian E Nett; Robert Brauweiler; Willi Kalender; Howard Rowley; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2010-04-01       Impact factor: 3.609

7.  Quantitative and qualitative evaluation of geometric deconvolution of distortion in limited-view computed tomography.

Authors:  P Soble; R M Rangayyan; R Gordon
Journal:  IEEE Trans Biomed Eng       Date:  1985-05       Impact factor: 4.538

8.  High temporal resolution and streak-free four-dimensional cone-beam computed tomography.

Authors:  Shuai Leng; Jie Tang; Joseph Zambelli; Brian Nett; Ranjini Tolakanahalli; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2008-09-24       Impact factor: 3.609

9.  Streaking artifacts reduction in four-dimensional cone-beam computed tomography.

Authors:  Shuai Leng; Joseph Zambelli; Ranjini Tolakanahalli; Brian Nett; Peter Munro; Joshua Star-Lack; Bhudatt Paliwal; Guang-Hong Chen
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

10.  Fast, high-resolution in vivo cine magnetic resonance imaging in normal and failing mouse hearts on a vertical 11.7 T system.

Authors:  Jürgen E Schneider; Paul J Cassidy; Craig Lygate; Damian J Tyler; Frank Wiesmann; Stuart M Grieve; Karen Hulbert; Kieran Clarke; Stefan Neubauer
Journal:  J Magn Reson Imaging       Date:  2003-12       Impact factor: 4.813

View more
  13 in total

1.  Improving low-dose blood-brain barrier permeability quantification using sparse high-dose induced prior for Patlak model.

Authors:  Ruogu Fang; Kolbeinn Karlsson; Tsuhan Chen; Pina C Sanelli
Journal:  Med Image Anal       Date:  2013-10-17       Impact factor: 8.545

2.  Dual-energy micro-CT of the rodent lung.

Authors:  C T Badea; X Guo; D Clark; S M Johnston; C D Marshall; C A Piantadosi
Journal:  Am J Physiol Lung Cell Mol Physiol       Date:  2012-03-16       Impact factor: 5.464

3.  Low-dose 4D cardiac imaging in small animals using dual source micro-CT.

Authors:  M Holbrook; D P Clark; C T Badea
Journal:  Phys Med Biol       Date:  2018-01-09       Impact factor: 3.609

4.  Novel Detection Scheme for X-ray Small-Angle Scattering.

Authors:  Guang Li; Wenxiang Cong; James S Michaelson; Hong Liu; Lars Gjesteby; Ge Wang
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2018-05-21

5.  Registration-based segmentation of murine 4D cardiac micro-CT data using symmetric normalization.

Authors:  Darin Clark; Alexandra Badea; Yilin Liu; G Allan Johnson; Cristian T Badea
Journal:  Phys Med Biol       Date:  2012-09-13       Impact factor: 3.609

6.  Low-dose cerebral perfusion computed tomography image restoration via low-rank and total variation regularizations.

Authors:  Shanzhou Niu; Shanli Zhang; Jing Huang; Zhaoying Bian; Wufan Chen; Gaohang Yu; Zhengrong Liang; Jianhua Ma
Journal:  Neurocomputing       Date:  2016-03-28       Impact factor: 5.719

7.  Iterative image reconstruction for cerebral perfusion CT using a pre-contrast scan induced edge-preserving prior.

Authors:  Jianhua Ma; Hua Zhang; Yang Gao; Jing Huang; Zhengrong Liang; Qianjing Feng; Wufan Chen
Journal:  Phys Med Biol       Date:  2012-10-26       Impact factor: 3.609

8.  Spectrotemporal CT data acquisition and reconstruction at low dose.

Authors:  Darin P Clark; Chang-Lung Lee; David G Kirsch; Cristian T Badea
Journal:  Med Phys       Date:  2015-11       Impact factor: 4.071

Review 9.  Micro-CT of rodents: state-of-the-art and future perspectives.

Authors:  D P Clark; C T Badea
Journal:  Phys Med       Date:  2014-06-26       Impact factor: 2.685

Review 10.  In vivo small animal micro-CT using nanoparticle contrast agents.

Authors:  Jeffrey R Ashton; Jennifer L West; Cristian T Badea
Journal:  Front Pharmacol       Date:  2015-11-04       Impact factor: 5.810

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.