Implementation of a cone-beam reconstruction algorithm for the single-circle source orbit with embedded misalignment correction using homogeneous coordinates.

M Karolczak1, S Schaller, K Engelke, A Lutz, U Taubenreuther, K Wiesent, W Kalender.   

Abstract

We present an efficient implementation of an approximate cone-beam image reconstruction algorithm for application in tomography, which accounts for scanner mechanical misalignment. The implementation is based on the algorithm proposed by Feldkamp et al. and is directed at circular scan paths. The algorithm has been developed for the purpose of reconstructing volume data from projections acquired in an experimental x-ray micro-tomography (microCT) scanner. To mathematically model misalignment we use matrix notation with homogeneous coordinates to describe the scanner geometry, its misalignment, and the acquisition process. For convenience analysis is carried out for x-ray CT scanners, but it is applicable to any tomographic modality, where two-dimensional projection acquisition in cone beam geometry takes place, e.g., single photon emission computerized tomography. We derive an algorithm assuming misalignment errors to be small enough to weight and filter original projections and to embed compensation for misalignment in the backprojection. We verify the algorithm on simulations of virtual phantoms and scans of a physical multidisk (Defrise) phantom.

Mesh:

Year:  2001        PMID: 11695767     DOI: 10.1118/1.1406514

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

1.  Quantifying the gantry sag on linear accelerators and introducing an MLC-based compensation strategy.

Authors:  Weiliang Du; Song Gao; Xiaochun Wang; Rajat J Kudchadker
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  A phantom-based calibration method for digital x-ray tomosynthesis.

Authors:  Hui Miao; Xizeng Wu; Huijuan Zhao; Hong Liu
Journal:  J Xray Sci Technol       Date:  2012       Impact factor: 1.535

3.  A geometric calibration method for cone beam CT systems.

Authors:  Kai Yang; Alexander L C Kwan; DeWitt F Miller; John M Boone
Journal:  Med Phys       Date:  2006-06       Impact factor: 4.071

Review 4.  Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.

Authors:  Xiaochuan Pan; Jeffrey Siewerdsen; Patrick J La Riviere; Willi A Kalender
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

5.  Geometric calibration for a dual tube/detector micro-CT system.

Authors:  Samuel M Johnston; G Allan Johnson; Cristian T Badea
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

6.  Improving dose calculation accuracy in preclinical radiation experiments using multi-energy element resolved cone-beam CT.

Authors:  Yanqi Huang; Xiaoyu Hu; Yuncheng Zhong; Youfang Lai; Chenyang Shen; Xun Jia
Journal:  Phys Med Biol       Date:  2021-12-06       Impact factor: 3.609

7.  Self-calibration of a cone-beam micro-CT system.

Authors:  V Patel; R N Chityala; K R Hoffmann; C N Ionita; D R Bednarek; S Rudin
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

8.  Geometric Parameters Estimation and Calibration in Cone-Beam Micro-CT.

Authors:  Jintao Zhao; Xiaodong Hu; Jing Zou; Xiaotang Hu
Journal:  Sensors (Basel)       Date:  2015-09-09       Impact factor: 3.576

9.  Technical evaluation of the cone-beam computed tomography imaging performance of a novel, mobile, gantry-based X-ray system for brachytherapy.

Authors:  Andre Karius; Marek Karolczak; Vratislav Strnad; Christoph Bert
Journal:  J Appl Clin Med Phys       Date:  2021-12-14       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.