Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: image-based correction of gantry motion nonidealities.

R Fahrig1, D W Holdsworth.   

Abstract

The image quality of 3D reconstructions produced using a C-arm mounted XRII depends on precise determination of the geometric parameters that describe the detector system in the laboratory frame of reference. We have designed a simplified calibration system that depends on images of a metal sphere, acquired during rotation of the gantry through 200 degrees. Angle-dependent shift corrections are obtained, accounting for nonideal motion in two directions: perpendicular to the axis of rotation and tangential to the circular trajectory (tau), and parallel to the axis of rotation (xi). Projection images are corrected prior to reconstruction using a simple shift-interpolation algorithm. We show that the motion of the gantry is highly reproducible during acquisitions within one day (mean standard deviation in tau and xi is 0.11 mm and 0.08 mm, respectively), and over 21 months (mean standard deviation in tau and xi is 0.10 mm and 0.06 mm, respectively). Reconstruction of a small-bead phantom demonstrates uniformity of the correction algorithm over the full volume of the reconstruction [standard deviation of full-width-half-maximum of the beads is approximately 0.25 pixels (0.13 mm) over the volume of reconstruction]. Our approach provides a simple correction technique that can be applied when trajectory deviations are significant relative to the pixel size of the detector but small relative to the detector field of view, and when the fan angle of the acquisition geometry is small (<20 degrees). A comparison with other calibration techniques in the literature is provided.

Entities:  

Mesh:

Year:  2000        PMID: 10659735     DOI: 10.1118/1.598854

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  24 in total

1.  Quantifying the gantry sag on linear accelerators and introducing an MLC-based compensation strategy.

Authors:  Weiliang Du; Song Gao; Xiaochun Wang; Rajat J Kudchadker
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

Review 2.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

3.  Exact and approximate cone-beam reconstruction algorithms for C-arm based cone-beam CT using a two-concentric-arc source trajectory.

Authors:  Tingliang Zhuang; Joseph Zambelli; Brian Nett; Shuai Leng; Guang-Hong Chen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

4.  Precise X-ray and video overlay for augmented reality fluoroscopy.

Authors:  Xin Chen; Lejing Wang; Pascal Fallavollita; Nassir Navab
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-05-17       Impact factor: 2.924

5.  A dynamic model-based approach to motion and deformation tracking of prosthetic valves from biplane x-ray images.

Authors:  Martin G Wagner; Charles R Hatt; David A P Dunkerley; Lindsay E Bodart; Amish N Raval; Michael A Speidel
Journal:  Med Phys       Date:  2018-05-03       Impact factor: 4.071

Review 6.  Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.

Authors:  Xiaochuan Pan; Jeffrey Siewerdsen; Patrick J La Riviere; Willi A Kalender
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

7.  Geometric calibration for a dual tube/detector micro-CT system.

Authors:  Samuel M Johnston; G Allan Johnson; Cristian T Badea
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

8.  Geometric calibration of a mobile C-arm for intraoperative cone-beam CT.

Authors:  M J Daly; J H Siewerdsen; Y B Cho; D A Jaffray; J C Irish
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

9.  Development of a QA phantom and automated analysis tool for geometric quality assurance of on-board MV and kV x-ray imaging systems.

Authors:  Weihua Mao; Louis Lee; Lei Xing
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

10.  Self-calibration of a cone-beam micro-CT system.

Authors:  V Patel; R N Chityala; K R Hoffmann; C N Ionita; D R Bednarek; S Rudin
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071