Geometrical calibration of X-ray imaging chains for three-dimensional reconstruction.

A Rougée1, C Picard, C Ponchut, Y Trousset.   

Abstract

Reconstructing a three-dimensional (3D) object from a set of its two-dimensional (2D) X-ray projections requires that the source position and image plane orientation in 3D space be obtained with high accuracy. We present a method for estimating the geometrical parameters of an X-ray imaging chain, based on the minimization of the reprojection mean quadratic error measured on reference points of a calibration phantom. This error is explicitly calculated with respect to the geometrical parameters of the conic projection, and a conjugate gradient technique is used for its minimization. By comparison to the classical unconstrained method, better results were obtained in simulation with our method, specially when only a few reference points are available. This method may be adapted to different X-ray systems and may also be extended to the estimation of the geometrical parameters of the imaging chain trajectory in the case of dynamic acquisitions.

Mesh:

Year:  1993        PMID: 8306301     DOI: 10.1016/0895-6111(93)90020-n

Source DB:  PubMed          Journal:  Comput Med Imaging Graph        ISSN: 0895-6111            Impact factor:   4.790


  13 in total

Review 1.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

2.  C-arm based cone-beam CT using a two-concentric-arc source trajectory: system evaluation.

Authors:  Joseph Zambelli; Tingliang Zhuang; Brian E Nett; Cyril Riddell; Barry Belanger; Guang-Hong Chen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008

3.  Feasibility of respiratory motion-compensated stereoscopic X-ray tracking for bronchoscopy.

Authors:  Nikolas Leßmann; Daniel Drömann; Alexander Schlaefer
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-07-26       Impact factor: 2.924

4.  Geometric calibration for a dual tube/detector micro-CT system.

Authors:  Samuel M Johnston; G Allan Johnson; Cristian T Badea
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

5.  Geometric calibration of a mobile C-arm for intraoperative cone-beam CT.

Authors:  M J Daly; J H Siewerdsen; Y B Cho; D A Jaffray; J C Irish
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

6.  Development of a QA phantom and automated analysis tool for geometric quality assurance of on-board MV and kV x-ray imaging systems.

Authors:  Weihua Mao; Louis Lee; Lei Xing
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

Review 7.  [Basic principles of flat detector computed tomography (FD-CT)].

Authors:  Y Kyriakou; T Struffert; A Dörfler; W A Kalender
Journal:  Radiologe       Date:  2009-09       Impact factor: 0.635

8.  Fiducial marker-based correction for involuntary motion in weight-bearing C-arm CT scanning of knees. II. Experiment.

Authors:  Jang-Hwan Choi; Andreas Maier; Andreas Keil; Saikat Pal; Emily J McWalter; Gary S Beaupré; Garry E Gold; Rebecca Fahrig
Journal:  Med Phys       Date:  2014-06       Impact factor: 4.071

9.  Evaluation of modern camera calibration techniques for conventional diagnostic X-ray imaging settings.

Authors:  Francisco Albiol; Alberto Corbi; Alberto Albiol
Journal:  Radiol Phys Technol       Date:  2016-07-18

10.  Self-calibration of a cone-beam micro-CT system.

Authors:  V Patel; R N Chityala; K R Hoffmann; C N Ionita; D R Bednarek; S Rudin
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071