Determination of both mechanical and electronic shifts in cone beam SPECT.

J Li1, R J Jaszczak, H Wang, K L Greer, R E Coleman.   

Abstract

The difference between the displacement of the centre of rotation (mechanical shift, MS) and the electronic centring misalignment (electronic shift, ES) in cone beam SPECT is evaluated. A method is proposed to determine both MS and ES using the centroid of a projected point source sampled over 360 degrees and the Marquardt non-linear fitting algorithm. Both shifts are characterized by two orthogonal components. This method is verified using Monte Carlo simulated point source data with different combinations of mechanical and electronic shifts. Both shifts can be determined correctly. We have also applied the proposed method to our cone beam SPECT system to determine both shifts as well as the focal length. The determined ES parameters are then used to correct the projections and the MS parameters are incorporated into a reconstruction algorithm. The point source images are reconstructed and the image resolutions with and without the shift corrections are measured. The experimental results demonstrate that the image resolution is improved after shift corrections. The experimental results also indicate that the shift parameters determined in the same experiment with the point source located at different places are consistent but change from time to time, suggesting that calibration of the system is needed on a periodic basis.

Mesh:

Year:  1993        PMID: 8346283     DOI: 10.1088/0031-9155/38/6/008

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Geometric characterization of multi-axis multi-pinhole SPECT.

Authors:  Frank P DiFilippo
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

2.  Geometric calibration for a dual tube/detector micro-CT system.

Authors:  Samuel M Johnston; G Allan Johnson; Cristian T Badea
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

3.  A detector response function design in pinhole SPECT including geometrical calibration.

Authors:  Z El Bitar; R H Huesman; R Boutchko; Virgile Bekaert; David Brasse; G T Gullberg
Journal:  Phys Med Biol       Date:  2013-03-15       Impact factor: 3.609

4.  Direct determination of geometric alignment parameters for cone-beam scanners.

Authors:  C Mennessier; R Clackdoyle; F Noo
Journal:  Phys Med Biol       Date:  2009-02-25       Impact factor: 3.609

Review 5.  The role of preclinical SPECT in oncological and neurological research in combination with either CT or MRI.

Authors:  Monique R Bernsen; Pieter E B Vaissier; Roel Van Holen; Jan Booij; Freek J Beekman; Marion de Jong
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-05       Impact factor: 9.236

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.