Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography.

F Noo1, R Clackdoyle, C Mennessier, T A White, T J Roney.   

Abstract

This paper is about calibration of cone-beam (CB) scanners for both x-ray computed tomography and single-photon emission computed tomography. Scanner calibration refers here to the estimation of a set of parameters which fully describe the geometry of data acquisition. Such parameters are needed for the tomographic reconstruction step. The discussion is limited to the usual case where the cone vertex and planar detector move along a circular path relative to the object. It is also assumed that the detector does not have spatial distortions. We propose a new method which requires a small set of measurements of a simple calibration object consisting of two spherical objects, that can be considered as 'point' objects. This object traces two ellipses on the detector and from the parametric description of these ellipses, the calibration geometry can be determined analytically using explicit formulae. The method is robust and easy to implement. However, it is not fully general as it is assumed that the detector is parallel to the rotation axis of the scanner. Implementation details are given for an experimental x-ray CB scanner.

Entities:  

Mesh:

Year:  2000        PMID: 11098919     DOI: 10.1088/0031-9155/45/11/327

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  32 in total

1.  Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research.

Authors:  Yidong Yang; Ken Kang-Hsin Wang; Sohrab Eslami; Iulian I Iordachita; Michael S Patterson; John W Wong
Journal:  Med Phys       Date:  2015-04       Impact factor: 4.071

2.  A geometric calibration method for cone beam CT systems.

Authors:  Kai Yang; Alexander L C Kwan; DeWitt F Miller; John M Boone
Journal:  Med Phys       Date:  2006-06       Impact factor: 4.071

3.  Geometric characterization of multi-axis multi-pinhole SPECT.

Authors:  Frank P DiFilippo
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

4.  A line-source method for aligning on-board and other pinhole SPECT systems.

Authors:  Susu Yan; James Bowsher; Fang-Fang Yin
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

5.  Development of ultrafast laser-based x-ray in-vivo phase-contrast micro-CT beamline for biomedical applications at Advanced Laser Light Source (ALLS).

Authors:  Russell Kincaid; Andrzej Krol; Sylvain Fourmaux; Jean-Claude Kieffer; Cristina Serbanescu; Marina Servol; Levon Vogelsang; Steve Wilkins; Andrew Stevenson; Yakov Nesterets; Edward Lipson; Hongwei Ye; Andrew Pogany
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008-01-01

6.  Geometric calibration for a dual tube/detector micro-CT system.

Authors:  Samuel M Johnston; G Allan Johnson; Cristian T Badea
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

7.  Geometric calibration of a mobile C-arm for intraoperative cone-beam CT.

Authors:  M J Daly; J H Siewerdsen; Y B Cho; D A Jaffray; J C Irish
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

8.  Estimation of CT cone-beam geometry using a novel method insensitive to phantom fabrication inaccuracy: implications for isocenter localization accuracy.

Authors:  J Chetley Ford; Dandan Zheng; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

9.  Bow-tie wobble artifact: effect of source assembly motion on cone-beam CT.

Authors:  Dandan Zheng; John C Ford; Jun Lu; Dimitrios Lazos; Geoffrey D Hugo; Damodar Pokhrel; Lisha Zhang; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-05       Impact factor: 4.071

10.  Self-calibration of a cone-beam micro-CT system.

Authors:  V Patel; R N Chityala; K R Hoffmann; C N Ionita; D R Bednarek; S Rudin
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.