MicroRT-small animal conformal irradiator.

S Stojadinovic1, D A Low, A J Hope, M Vicic, J O Deasy, J Cui, D Khullar, P J Parikh, K T Malinowski, E W Izaguirre, S Mutic, P W Grigsby.   

Abstract

A novel small animal conformal radiation therapy system has been designed and prototyped: MicroRT. The microRT system integrates multimodality imaging, radiation treatment planning, and conformal radiation therapy that utilizes a clinical 192Ir isotope high dose rate source as the radiation source (teletherapy). A multiparameter dose calculation algorithm based on Monte Carlo dose distribution simulations is used to efficiently and accurately calculate doses for treatment planning purposes. A series of precisely machined tungsten collimators mounted onto a cylindrical collimator assembly is used to provide the radiation beam portals. The current design allows a source-to-target distance range of 1-8 cm at four beam angles: 0 degrees (beam oriented down), 90 degrees, 180 degrees, and 270 degrees. The animal is anesthetized and placed in an immobilization device with built-in fiducial markers and scanned using a computed tomography, magnetic resonance, or positron emission tomography scanner prior to irradiation. Treatment plans using up to four beam orientations are created utilizing a custom treatment planning system-microRTP. A three-axis computer-controlled stage that supports and accurately positions the animals is programmed to place the animal relative to the radiation beams according to the microRTP plan. The microRT system positioning accuracy was found to be submillimeter. The radiation source is guided through one of four catheter channels and placed in line with the tungsten collimators to deliver the conformal radiation treatment. The microRT hardware specifications, the accuracy of the treatment planning and positioning systems, and some typical procedures for radiobiological experiments that can be performed with the microRT device are presented.

Mesh:

Substances:

Year:  2007        PMID: 18196798     DOI: 10.1118/1.2799887

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  44 in total

1.  Monte Carlo calculated absorbed-dose energy dependence of EBT and EBT2 film.

Authors:  J G H Sutherland; D W O Rogers
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

2.  Advanced Small Animal Conformal Radiation Therapy Device.

Authors:  Sunil Sharma; Ganesh Narayanasamy; Beata Przybyla; Jessica Webber; Marjan Boerma; Richard Clarkson; Eduardo G Moros; Peter M Corry; Robert J Griffin
Journal:  Technol Cancer Res Treat       Date:  2016-07-08

Review 3.  Hi-tech systems for in-vivo image-guided preclinical radiobiology.

Authors:  Giovanni Lucignani
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-12       Impact factor: 9.236

4.  Scanning irradiation device for mice in vivo with pulsed and continuous proton beams.

Authors:  Christoph Greubel; Walter Assmann; Christian Burgdorf; Günther Dollinger; Guanghua Du; Volker Hable; Alexander Hapfelmeier; Ralf Hertenberger; Peter Kneschaurek; Dörte Michalski; Michael Molls; Sabine Reinhardt; Barbara Röper; Stefan Schell; Thomas E Schmid; Christian Siebenwirth; Tatiana Wenzl; Olga Zlobinskaya; Jan J Wilkens
Journal:  Radiat Environ Biophys       Date:  2011-05-10       Impact factor: 1.925

5.  Investigation of the effects of treatment planning variables in small animal radiotherapy dose distributions.

Authors:  Amy R Motomura; Magdalena Bazalova; Hu Zhou; Paul J Keall; Edward E Graves
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

6.  Characterization of image quality and image-guidance performance of a preclinical microirradiator.

Authors:  R Clarkson; P E Lindsay; S Ansell; G Wilson; S Jelveh; R P Hill; D A Jaffray
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

7.  Kilovoltage beam Monte Carlo dose calculations in submillimeter voxels for small animal radiotherapy.

Authors:  Magdalena Bazalova; Hu Zhou; Paul J Keall; Edward E Graves
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

8.  Development and dosimetry of a small animal lung irradiation platform.

Authors:  Ross McGurk; Caroline Hadley; Isabel L Jackson; Zeljko Vujaskovic
Journal:  Health Phys       Date:  2012-10       Impact factor: 1.316

9.  Image-guided small animal radiation research platform: calibration of treatment beam alignment.

Authors:  Mohammad Matinfar; Eric Ford; Iulian Iordachita; John Wong; Peter Kazanzides
Journal:  Phys Med Biol       Date:  2009-01-14       Impact factor: 3.609

10.  Development and Validation of a Small Animal Immobilizer and Positioning System for the Study of Delivery of Intracranial and Extracranial Radiotherapy Using the Gamma Knife System.

Authors:  Musaddiq J Awan; Jennifer Dorth; Arvind Mani; Haksoo Kim; Yiran Zheng; Mazen Mislmani; Scott Welford; Jiankui Yuan; Barry W Wessels; Simon S Lo; John Letterio; Mitchell Machtay; Andrew Sloan; Jason W Sohn
Journal:  Technol Cancer Res Treat       Date:  2016-07-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.