Literature DB >> 23091878

Development and dosimetry of a small animal lung irradiation platform.

Ross McGurk1, Caroline Hadley, Isabel L Jackson, Zeljko Vujaskovic.   

Abstract

Advances in large scale screening of medical countermeasures for radiation-induced normal tissue toxicity are currently hampered by animal irradiation paradigms that are both inefficient and highly variable among institutions. Here, a novel high-throughput small animal irradiation platform is introduced for use in orthovoltage small animal irradiators. Radiochromic film and metal oxide semiconductor field effect transistor detectors were used to examine several parameters, including 2D field uniformity, dose rate consistency, and shielding transmission. The authors posit that this setup will improve efficiency of drug screens by allowing for simultaneous targeted irradiation of multiple animals to improve efficiency within a single institution. Additionally, they suggest that measurement of the described parameters in all centers conducting countermeasure studies will improve the translatability of findings among institutions. The use of tissue equivalent phantoms in performing dosimetry measurements for small animal irradiation experiments was also investigated. Though these phantoms are commonly used in dosimetry, the authors recorded a significant difference in both the entrance and target tissue dose rates between euthanized rats and mice with implanted detectors and the corresponding phantom measurement. This suggests that measurements using these phantoms may not provide accurate dosimetry for in vivo experiments. Based on these measurements, the authors propose that this small animal irradiation platform can increase the capacity of animal studies by allowing for more efficient animal irradiation. They also suggest that researchers fully characterize the parameters of whatever radiation setup is in use in order to facilitate better comparison among institutions.

Entities:  

Mesh:

Year:  2012        PMID: 23091878      PMCID: PMC4615601          DOI: 10.1097/hp.0b013e3182632526

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  22 in total

1.  Medicine. Modulation of radiation injury.

Authors:  C Norman Coleman; Helen B Stone; John E Moulder; Terry C Pellmar
Journal:  Science       Date:  2004-04-30       Impact factor: 47.728

2.  Models for evaluating agents intended for the prophylaxis, mitigation and treatment of radiation injuries. Report of an NCI Workshop, December 3-4, 2003.

Authors:  Helen B Stone; John E Moulder; C Norman Coleman; K Kian Ang; Mitchell S Anscher; Mary Helen Barcellos-Hoff; William S Dynan; John R Fike; David J Grdina; Joel S Greenberger; Martin Hauer-Jensen; Richard P Hill; Richard N Kolesnick; Thomas J Macvittie; Cheryl Marks; William H McBride; Noelle Metting; Terry Pellmar; Mary Purucker; Mike E Robbins; Robert H Schiestl; Thomas M Seed; Joseph E Tomaszewski; Elizabeth L Travis; Paul E Wallner; Mary Wolpert; Daniel Zaharevitz
Journal:  Radiat Res       Date:  2004-12       Impact factor: 2.841

Review 3.  Priority list of research areas for radiological nuclear threat countermeasures.

Authors:  Terry C Pellmar; Sara Rockwell
Journal:  Radiat Res       Date:  2005-01       Impact factor: 2.841

4.  Application of commercial MOSFET detectors for in vivo dosimetry in the therapeutic x-ray range from 80 kV to 250 kV.

Authors:  Christian Ehringfeld; Susanne Schmid; Karin Poljanc; Christian Kirisits; Hannes Aiginger; Dietmar Georg
Journal:  Phys Med Biol       Date:  2005-01-21       Impact factor: 3.609

5.  Energy and integrated dose dependence of MOSFET dosimeter sensitivity for irradiation energies between 30 kV and 60Co.

Authors:  Marie-Claude Lavallée; Luc Gingras; Luc Beaulieu
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

6.  Animal models for radiation injury, protection and therapy.

Authors:  Alison Deckhut Augustine; Timothy Gondré-Lewis; William McBride; Lara Miller; Terry C Pellmar; Sara Rockwell
Journal:  Radiat Res       Date:  2005-07       Impact factor: 2.841

7.  Validation of metal oxide semiconductor field effect transistor technology for organ dose assessment during CT: comparison with thermoluminescent dosimetry.

Authors:  Terry T Yoshizumi; Philip C Goodman; Donald P Frush; Giao Nguyen; Greta Toncheva; Maksudur Sarder; Lottie Barnes
Journal:  AJR Am J Roentgenol       Date:  2007-05       Impact factor: 3.959

8.  MicroRT-small animal conformal irradiator.

Authors:  S Stojadinovic; D A Low; A J Hope; M Vicic; J O Deasy; J Cui; D Khullar; P J Parikh; K T Malinowski; E W Izaguirre; S Mutic; P W Grigsby
Journal:  Med Phys       Date:  2007-12       Impact factor: 4.071

Review 9.  Dose fractionation, dose rate and iso-effect relationships for normal tissue responses.

Authors:  G W Barendsen
Journal:  Int J Radiat Oncol Biol Phys       Date:  1982-11       Impact factor: 7.038

10.  An implantable radiation dosimeter for use in external beam radiation therapy.

Authors:  Charles W Scarantino; David M Ruslander; Christopher J Rini; Gregory G Mann; H Troy Nagle; Robert D Black
Journal:  Med Phys       Date:  2004-09       Impact factor: 4.071

View more
  7 in total

1.  A preclinical rodent model of radiation-induced lung injury for medical countermeasure screening in accordance with the FDA animal rule.

Authors:  Isabel L Jackson; Puting Xu; Caroline Hadley; Barry P Katz; Ross McGurk; Julian D Down; Zeljko Vujaskovic
Journal:  Health Phys       Date:  2012-10       Impact factor: 1.316

2.  Immediate Release of Gastrin-Releasing Peptide Mediates Delayed Radiation-Induced Pulmonary Fibrosis.

Authors:  Robert M Tighe; Karissa Heck; Erik Soderblom; Shutang Zhou; Anastasiya Birukova; Kenneth Young; Douglas Rouse; Jessica Vidas; Miglena K Komforti; Christopher B Toomey; Frank Cuttitta; Mary E Sunday
Journal:  Am J Pathol       Date:  2019-03-18       Impact factor: 4.307

3.  UNITED STATES DEPARTMENT OF HEALTH AND HUMAN SERVICES BIODOSIMETRY AND RADIOLOGICAL/NUCLEAR MEDICAL COUNTERMEASURE PROGRAMS.

Authors:  Mary J Homer; Robert Raulli; Andrea L DiCarlo-Cohen; John Esker; Chad Hrdina; Bert W Maidment; Brian Moyer; Carmen Rios; Francesca Macchiarini; Pataje G Prasanna; Lynne Wathen
Journal:  Radiat Prot Dosimetry       Date:  2016-09-02       Impact factor: 0.972

4.  A preclinical radiotherapy dosimetry audit using a realistic 3D printed murine phantom.

Authors:  Emma R Biglin; Adam H Aitkenhead; Gareth J Price; Amy L Chadwick; Elham Santina; Kaye J Williams; Karen J Kirkby
Journal:  Sci Rep       Date:  2022-04-26       Impact factor: 4.996

5.  Cerium Oxide Nanoparticles: A Potential Medical Countermeasure to Mitigate Radiation-Induced Lung Injury in CBA/J Mice.

Authors:  P-T Xu; B W Maidment; V Antonic; I L Jackson; S Das; A Zodda; X Zhang; S Seal; Z Vujaskovic
Journal:  Radiat Res       Date:  2016-05-02       Impact factor: 2.841

6.  Toward an organ based dose prescription method for the improved accuracy of murine dose in orthovoltage x-ray irradiators.

Authors:  Matthew D Belley; Chu Wang; Giao Nguyen; Rathnayaka Gunasingha; Nelson J Chao; Benny J Chen; Mark W Dewhirst; Terry T Yoshizumi
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

7.  Study logistics that can impact medical countermeasure efficacy testing in mouse models of radiation injury.

Authors:  Andrea L DiCarlo; Zulmarie Perez Horta; Carmen I Rios; Merriline M Satyamitra; Lanyn P Taliaferro; David R Cassatt
Journal:  Int J Radiat Biol       Date:  2020-09-24       Impact factor: 2.694

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.