Literature DB >> 27444980

Development and Validation of a Small Animal Immobilizer and Positioning System for the Study of Delivery of Intracranial and Extracranial Radiotherapy Using the Gamma Knife System.

Musaddiq J Awan1, Jennifer Dorth1, Arvind Mani2, Haksoo Kim1, Yiran Zheng1, Mazen Mislmani1, Scott Welford1, Jiankui Yuan1, Barry W Wessels1, Simon S Lo1, John Letterio3, Mitchell Machtay1, Andrew Sloan4, Jason W Sohn1.   

Abstract

The purpose of this research is to establish a process of irradiating mice using the Gamma Knife as a versatile system for small animal irradiation and to validate accurate intracranial and extracranial dose delivery using this system. A stereotactic immobilization device was developed for small animals for the Gamma Knife head frame allowing for isocentric dose delivery. Intercranial positional reproducibility of a reference point from a primary reference animal was verified on an additional mouse. Extracranial positional reproducibility of the mouse aorta was verified using 3 mice. Accurate dose delivery was validated using film and thermoluminescent dosimeter measurements with a solid water phantom. Gamma Knife plans were developed to irradiate intracranial and extracranial targets. Mice were irradiated validating successful targeted radiation dose delivery. Intramouse positional variability of the right mandible reference point across 10 micro-computed tomography scans was 0.65 ± 0.48 mm. Intermouse positional reproducibility across 2 mice at the same reference point was 0.76 ± 0.46 mm. The accuracy of dose delivery was 0.67 ± 0.29 mm and 1.01 ± 0.43 mm in the coronal and sagittal planes, respectively. The planned dose delivered to a mouse phantom was 2 Gy at the 50% isodose with a measured thermoluminescent dosimeter dose of 2.9 ± 0.3 Gy. The phosphorylated form of member X of histone family H2A (γH2AX) staining of irradiated mouse brain and mouse aorta demonstrated adjacent tissue sparing. In conclusion, our system for preclinical studies of small animal irradiation using the Gamma Knife is able to accurately deliver intracranial and extracranial targeted focal radiation allowing for preclinical experiments studying focal radiation.

Entities:  

Keywords:  conformal radiotherapy; preclinical models; radiation biology; radiation physics; small animal irradiation

Mesh:

Year:  2016        PMID: 27444980      PMCID: PMC5616031          DOI: 10.1177/1533034616658394

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  18 in total

Review 1.  Intensity modulated radiation therapy: a review of current practice and future directions.

Authors:  Mona Sanghani; John Mignano
Journal:  Technol Cancer Res Treat       Date:  2006-10

2.  Characterization of image quality and image-guidance performance of a preclinical microirradiator.

Authors:  R Clarkson; P E Lindsay; S Ansell; G Wilson; S Jelveh; R P Hill; D A Jaffray
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

3.  Gamma Knife irradiation method based on dosimetric controls to target small areas in rat brains.

Authors:  Julie Constanzo; Benoit Paquette; Gabriel Charest; Laurence Masson-Côté; Mathieu Guillot
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

4.  Localized CT-guided irradiation inhibits neurogenesis in specific regions of the adult mouse brain.

Authors:  E C Ford; P Achanta; D Purger; M Armour; J Reyes; J Fong; L Kleinberg; K Redmond; J Wong; M H Jang; H Jun; H-J Song; A Quinones-Hinojosa
Journal:  Radiat Res       Date:  2011-03-30       Impact factor: 2.841

5.  Frameless stereotactic radiosurgery for the treatment of primary intracranial tumours in dogs.

Authors:  C L Mariani; T A Schubert; R A House; M A Wong; A L Hopkins; H L Barnes Heller; R J Milner; N V Lester; D M Lurie; D A Rajon; W A Friedman; F J Bova
Journal:  Vet Comp Oncol       Date:  2013-09-06       Impact factor: 2.613

6.  An integrated method for reproducible and accurate image-guided stereotactic cranial irradiation of brain tumors using the small animal radiation research platform.

Authors:  Brian C Baumann; Joseph L Benci; Phillip P Santoiemma; Sanjay Chandrasekaran; Andrew B Hollander; Gary D Kao; Jay F Dorsey
Journal:  Transl Oncol       Date:  2012-08-01       Impact factor: 4.243

7.  Partial volume rat lung irradiation: the protective/mitigating effects of Eukarion-189, a superoxide dismutase-catalase mimetic.

Authors:  Aimée R Langan; Mohammed A Khan; Ivan W T Yeung; Jake Van Dyk; Richard P Hill
Journal:  Radiother Oncol       Date:  2006-05-03       Impact factor: 6.280

Review 8.  Stereotactic body radiotherapy.

Authors:  Laura Kollar; Ramesh Rengan
Journal:  Semin Oncol       Date:  2014-10-07       Impact factor: 4.929

9.  High-resolution, small animal radiation research platform with x-ray tomographic guidance capabilities.

Authors:  John Wong; Elwood Armour; Peter Kazanzides; Iulian Iordachita; Erik Tryggestad; Hua Deng; Mohammad Matinfar; Christopher Kennedy; Zejian Liu; Timothy Chan; Owen Gray; Frank Verhaegen; Todd McNutt; Eric Ford; Theodore L DeWeese
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-08-01       Impact factor: 7.038

10.  Commissioning and evaluation of a new commercial small rodent x-ray irradiator.

Authors:  Mk Woo; Ra Nordal
Journal:  Biomed Imaging Interv J       Date:  2006-01-01
View more
  2 in total

1.  The Ig superfamily protein PTGFRN coordinates survival signaling in glioblastoma multiforme.

Authors:  Brittany Aguila; Adina Brett Morris; Raffaella Spina; Eli Bar; Julie Schraner; Robert Vinkler; Jason W Sohn; Scott M Welford
Journal:  Cancer Lett       Date:  2019-08-01       Impact factor: 8.679

2.  MCT4 regulates de novo pyrimidine biosynthesis in GBM in a lactate-independent manner.

Authors:  Raffaella Spina; Dillon M Voss; Xiaohua Yang; Jason W Sohn; Robert Vinkler; Julianna Schraner; Anthony Sloan; Scott M Welford; Norbert Avril; Heather M Ames; Graeme F Woodworth; Eli E Bar
Journal:  Neurooncol Adv       Date:  2020-01-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.