Literature DB >> 19994508

Kilovoltage beam Monte Carlo dose calculations in submillimeter voxels for small animal radiotherapy.

Magdalena Bazalova1, Hu Zhou, Paul J Keall, Edward E Graves.   

Abstract

PURPOSE: Small animal conformal radiotherapy (RT) is essential for preclinical cancer research studies and therefore various microRT systems have been recently designed. The aim of this paper is to efficiently calculate the dose delivered using our microRT system based on a microCT scanner with the Monte Carlo (MC) method and to compare the MC calculations to film measurements.
METHODS: Doses from 2-30 mm diameter 120 kVp photon beams deposited in a solid water phantom with 0.2 x 0.2 x 0.2 mm3 voxels are calculated using the latest versions of the EGSnrc codes BEAMNRC and DOSXYZNRC. Two dose calculation approaches are studied: a two-step approach using phase-space files and direct dose calculation with BEAMNRC simulation sources. Due to the small beam size and submillimeter voxel size resulting in long calculation times, variance reduction techniques are studied. The optimum bremsstrahlung splitting number (NBRSPL in BEAMNRC) and the optimum DOSXYZNRC photon splitting (Nsplit) number are examined for both calculation approaches and various beam sizes. The dose calculation efficiencies and the required number of histories to achieve 1% statistical uncertainty--with no particle recycling--are evaluated for 2-30 mm beams. As a final step, film dose measurements are compared to MC calculated dose distributions.
RESULTS: The optimum NBRSPL is approximately 1 x 10(6) for both dose calculation approaches. For the dose calculations with phase-space files, Nsplit varies only slightly for 2-30 mm beams and is established to be 300. Nsplit for the DOSXYZNRC calculation with the BEAMNRC source ranges from 300 for the 30 mm beam to 4000 for the 2 mm beam. The calculation time significantly increases for small beam sizes when the BEAMNRC simulation source is used compared to the simulations with phase-space files. For the 2 and 30 mm beams, the dose calculations with phase-space files are more efficient than the dose calculations with BEAMNRC sources by factors of 54 and 1.6, respectively. The dose calculation efficiencies converge for beams with diameters larger than 30 mm.
CONCLUSIONS: A very good agreement of MC calculated dose distributions to film measurements is found. The mean difference of percentage depth dose curves between calculated and measured data for 2, 5, 10, and 20 mm beams is 1.8%.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19994508      PMCID: PMC2773455          DOI: 10.1118/1.3238465

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  26 in total

1.  Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version.

Authors:  I Kawrakow
Journal:  Med Phys       Date:  2000-03       Impact factor: 4.071

2.  On the efficiency of photon beam treatment head simulations.

Authors:  Iwan Kawrakow
Journal:  Med Phys       Date:  2005-07       Impact factor: 4.071

3.  Efficient photon beam dose calculations using DOSXYZnrc with BEAMnrc.

Authors:  I Kawrakow; B R B Walters
Journal:  Med Phys       Date:  2006-08       Impact factor: 4.071

4.  Efficient x-ray tube simulations.

Authors:  Ernesto Mainegra-Hing; Iwan Kawrakow
Journal:  Med Phys       Date:  2006-08       Impact factor: 4.071

5.  BEAM: a Monte Carlo code to simulate radiotherapy treatment units.

Authors:  D W Rogers; B A Faddegon; G X Ding; C M Ma; J We; T R Mackie
Journal:  Med Phys       Date:  1995-05       Impact factor: 4.071

6.  Orthovoltage radiation therapy treatment planning using Monte Carlo simulation: treatment of neuroendocrine carcinoma of the maxillary sinus.

Authors:  W Gao; D E Raeside
Journal:  Phys Med Biol       Date:  1997-12       Impact factor: 3.609

7.  Limitations in the determination of total filtration of x-ray tube assemblies.

Authors:  H D Nagel
Journal:  Phys Med Biol       Date:  1988-02       Impact factor: 3.609

8.  Neutron or photon irradiation for prostate tumors: enhancement of cytokine therapy in a metastatic tumor model.

Authors:  G G Hillman; R L Maughan; D J Grignon; M Yudelev; J Rubio; S Tekyi-Mensah; A Layer; M Che; J D Forman
Journal:  Clin Cancer Res       Date:  2001-01       Impact factor: 12.531

9.  Partial volume rat lung irradiation: an evaluation of early DNA damage.

Authors:  M A Khan; R P Hill; J Van Dyk
Journal:  Int J Radiat Oncol Biol Phys       Date:  1998-01-15       Impact factor: 7.038

10.  Large efficiency improvements in BEAMnrc using directional bremsstrahlung splitting.

Authors:  I Kawrakow; D W O Rogers; B R B Walters
Journal:  Med Phys       Date:  2004-10       Impact factor: 4.071

View more
  10 in total

1.  Investigation of the effects of treatment planning variables in small animal radiotherapy dose distributions.

Authors:  Amy R Motomura; Magdalena Bazalova; Hu Zhou; Paul J Keall; Edward E Graves
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

2.  The importance of tissue segmentation for dose calculations for kilovoltage radiation therapy.

Authors:  Magdalena Bazalova; Edward E Graves
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

3.  Adaptation, Commissioning, and Evaluation of a 3D Treatment Planning System for High-Resolution Small-Animal Irradiation.

Authors:  Jeho Jeong; Qing Chen; Robert Febo; Jie Yang; Hai Pham; Jian-Ping Xiong; Pat B Zanzonico; Joseph O Deasy; John L Humm; Gig S Mageras
Journal:  Technol Cancer Res Treat       Date:  2015-05-06

4.  Modality comparison for small animal radiotherapy: a simulation study.

Authors:  Magdalena Bazalova; Geoff Nelson; John M Noll; Edward E Graves
Journal:  Med Phys       Date:  2014-01       Impact factor: 4.071

5.  Toward an organ based dose prescription method for the improved accuracy of murine dose in orthovoltage x-ray irradiators.

Authors:  Matthew D Belley; Chu Wang; Giao Nguyen; Rathnayaka Gunasingha; Nelson J Chao; Benny J Chen; Mark W Dewhirst; Terry T Yoshizumi
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

6.  High throughput film dosimetry in homogeneous and heterogeneous media for a small animal irradiator.

Authors:  L Wack; W Ngwa; E Tryggestad; P Tsiamas; R Berbeco; S K Ng; J Hesser; P Zygmanski
Journal:  Phys Med       Date:  2013-03-17       Impact factor: 2.685

7.  Impact of backscatter material thickness on the depth dose of orthovoltage irradiators for radiobiology research.

Authors:  Quan Chen; Janelle Molloy; Tadahide Izumi; Edmond Sterpin
Journal:  Phys Med Biol       Date:  2019-02-20       Impact factor: 4.174

8.  A novel technique for image-guided local heart irradiation in the rat.

Authors:  Sunil Sharma; Eduardo G Moros; Marjan Boerma; Vijayalakshmi Sridharan; Eun Young Han; Richard Clarkson; Martin Hauer-Jensen; Peter M Corry
Journal:  Technol Cancer Res Treat       Date:  2013-08-31

9.  Evaluation of a Novel Liquid Fiducial Marker, BioXmark®, for Small Animal Image-Guided Radiotherapy Applications.

Authors:  Kathryn H Brown; Mihaela Ghita; Giuseppe Schettino; Kevin M Prise; Karl T Butterworth
Journal:  Cancers (Basel)       Date:  2020-05-18       Impact factor: 6.639

10.  Monte Carlo simulations of EBT3 film dose deposition for percentage depth dose (PDD) curve evaluation.

Authors:  Spencer M Robinson; Nolan Esplen; Derek Wells; Magdalena Bazalova-Carter
Journal:  J Appl Clin Med Phys       Date:  2020-11-06       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.