Image-guided small animal radiation research platform: calibration of treatment beam alignment.

Mohammad Matinfar1, Eric Ford, Iulian Iordachita, John Wong, Peter Kazanzides.   

Abstract

Small animal research allows detailed study of biological processes, disease progression and response to therapy with the potential to provide a natural bridge to the clinical environment. The small animal radiation research platform (SARRP) is a portable system for precision irradiation with beam sizes down to approximately 0.5 mm and optimally planned radiation with on-board cone-beam CT (CBCT) guidance. This paper focuses on the geometric calibration of the system for high-precision irradiation. A novel technique for the calibration of the treatment beam is presented, which employs an x-ray camera whose precise positioning need not be known. Using the camera system we acquired a digitally reconstructed 3D 'star shot' for gantry calibration and then developed a technique to align each beam to a common isocenter with the robotic animal positioning stages. The calibration incorporates localization by cone-beam CT guidance. Uncorrected offsets of the beams with respect to the calibration origin ranged from 0.4 mm to 5.2 mm. With corrections, these alignment errors can be reduced to the sub-millimeter range. The calibration technique was used to deliver a stereotactic-like arc treatment to a phantom constructed with EBT Gafchromic films. All beams were shown to intersect at a common isocenter with a measured beam (FWHM) of approximately 1.07 mm using the 0.5 mm collimated beam. The desired positioning accuracy of the SARRP is 0.25 mm and the results indicate an accuracy of 0.2 mm. To fully realize the radiation localization capabilities of the SARRP, precise geometric calibration is required, as with any such system. The x-ray camera-based technique presented here provides a straightforward and semi-automatic method for system calibration.

Entities:  

Mesh:

Year:  2009        PMID: 19141881      PMCID: PMC2964666          DOI: 10.1088/0031-9155/54/4/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  17 in total

1.  The stability of mechanical calibration for a kV cone beam computed tomography system integrated with linear accelerator.

Authors:  Michael B Sharpe; Douglas J Moseley; Thomas G Purdie; Mohammad Islam; Jeffrey H Siewerdsen; David A Jaffray
Journal:  Med Phys       Date:  2006-01       Impact factor: 4.071

2.  MicroRT-small animal conformal irradiator.

Authors:  S Stojadinovic; D A Low; A J Hope; M Vicic; J O Deasy; J Cui; D Khullar; P J Parikh; K T Malinowski; E W Izaguirre; S Mutic; P W Grigsby
Journal:  Med Phys       Date:  2007-12       Impact factor: 4.071

3.  Design and evaluation of a variable aperture collimator for conformal radiotherapy of small animals using a microCT scanner.

Authors:  Edward E Graves; Hu Zhou; Raja Chatterjee; Paul J Keall; Sanjiv Sam Gambhir; Christopher H Contag; Arthur L Boyer
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

4.  A novel high resolution micro-radiotherapy system for small animal irradiation for cancer research.

Authors:  Sigen Wang; Zhijun Liu; Shabana Sultana; Eric Schreiber; Otto Zhou; Sha Chang
Journal:  Biofactors       Date:  2007       Impact factor: 6.113

5.  Design of a radiation facility for very small specimens used in radiobiology studies.

Authors:  Manuel Rodriguez; Robert Jeraj
Journal:  Phys Med Biol       Date:  2008-05-12       Impact factor: 3.609

6.  Ultrasound backscatter microscope analysis of mouse melanoma progression.

Authors:  D H Turnbull; J A Ramsay; G S Shivji; T S Bloomfield; L From; D N Sauder; F S Foster
Journal:  Ultrasound Med Biol       Date:  1996       Impact factor: 2.998

7.  Elastic response of human iliac arteries in-vitro to balloon angioplasty using high-resolution CT.

Authors:  A O Medynsky; D W Holdsworth; M H Sherebrin; R N Rankin; M R Roach
Journal:  J Biomech       Date:  1998-08       Impact factor: 2.712

8.  Effect of gamma knife radiosurgery on rat brain sodium channel subunit mRNA expression.

Authors:  F Bartolomei; A Massacrier; M Rey; M Viale; J Régis; M Gastaldi; P Cau
Journal:  Stereotact Funct Neurosurg       Date:  1998-10       Impact factor: 1.875

9.  High-resolution, small animal radiation research platform with x-ray tomographic guidance capabilities.

Authors:  John Wong; Elwood Armour; Peter Kazanzides; Iulian Iordachita; Erik Tryggestad; Hua Deng; Mohammad Matinfar; Christopher Kennedy; Zejian Liu; Timothy Chan; Owen Gray; Frank Verhaegen; Todd McNutt; Eric Ford; Theodore L DeWeese
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-08-01       Impact factor: 7.038

10.  Use of the Leksell Gamma Knife for localized small field lens irradiation in rodents.

Authors:  Colleen DesRosiers; Marc S Mendonca; Craig Tyree; Vadim Moskvin; Morris Bank; Leo Massaro; Robert M Bigsby; Andrea Caperall-Grant; Shailaja Valluri; Joseph R Dynlacht; Robert Timmerman
Journal:  Technol Cancer Res Treat       Date:  2003-10
View more
  35 in total

1.  Advanced Small Animal Conformal Radiation Therapy Device.

Authors:  Sunil Sharma; Ganesh Narayanasamy; Beata Przybyla; Jessica Webber; Marjan Boerma; Richard Clarkson; Eduardo G Moros; Peter M Corry; Robert J Griffin
Journal:  Technol Cancer Res Treat       Date:  2016-07-08

2.  Functional interrogation of adult hypothalamic neurogenesis with focal radiological inhibition.

Authors:  Daniel A Lee; Juan Salvatierra; Esteban Velarde; John Wong; Eric C Ford; Seth Blackshaw
Journal:  J Vis Exp       Date:  2013-11-14       Impact factor: 1.355

3.  Investigation of the effects of treatment planning variables in small animal radiotherapy dose distributions.

Authors:  Amy R Motomura; Magdalena Bazalova; Hu Zhou; Paul J Keall; Edward E Graves
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

4.  The importance of tissue segmentation for dose calculations for kilovoltage radiation therapy.

Authors:  Magdalena Bazalova; Edward E Graves
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

5.  Characterization of image quality and image-guidance performance of a preclinical microirradiator.

Authors:  R Clarkson; P E Lindsay; S Ansell; G Wilson; S Jelveh; R P Hill; D A Jaffray
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

6.  Kilovoltage beam Monte Carlo dose calculations in submillimeter voxels for small animal radiotherapy.

Authors:  Magdalena Bazalova; Hu Zhou; Paul J Keall; Edward E Graves
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

7.  Development of a dynamic phantom and investigation of mobile target imaging and irradiation in preclinical small animal research.

Authors:  Anne-Marie Frelin-Labalme; Vincent Beaudouin
Journal:  Br J Radiol       Date:  2016-11-09       Impact factor: 3.039

8.  The potential impact of ultrathin filter design on dosimetry and relative biological effectiveness in modern image-guided small animal irradiators.

Authors:  Yannick Poirier; Christopher Daniel Johnstone; Charles Kirkby
Journal:  Br J Radiol       Date:  2018-11-15       Impact factor: 3.039

9.  Image-guided microbeam irradiation to brain tumour bearing mice using a carbon nanotube x-ray source array.

Authors:  Lei Zhang; Hong Yuan; Laurel M Burk; Christy R Inscoe; Michael J Hadsell; Pavel Chtcheprov; Yueh Z Lee; Jianping Lu; Sha Chang; Otto Zhou
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609

10.  Use of the NASA Space Radiation Laboratory at Brookhaven National Laboratory to Conduct Charged Particle Radiobiology Studies Relevant to Ion Therapy.

Authors:  Kathryn D Held; Eleanor A Blakely; Michael D Story; Derek I Lowenstein
Journal:  Radiat Res       Date:  2016-05-19       Impact factor: 2.841

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.