Validation of a Monte Carlo tool for patient-specific dose simulations in multi-slice computed tomography.

Paul Deak1, Marcel van Straten, Paul C Shrimpton, Maria Zankl, Willi A Kalender.   

Abstract

Estimating the dose delivered to the patient in X-ray computed tomography (CT) examinations is not a trivial task. Monte Carlo (MC) methods appear to be the method of choice to assess the 3D dose distribution. The purpose of this work was to extend an existing MC-based tool to account for arbitrary scanners and scan protocols such as multi-slice CT (MSCT) scanners and to validate the tool in homogeneous and heterogeneous phantoms. The tool was validated by measurements on MSCT scanners for different scan protocols under known conditions. Quantitative CT Dose Index (CTDI) measurements were performed in cylindrical CTDI phantoms and in anthropomorphic thorax phantoms of various sizes; dose profiles were measured with thermoluminescent dosimeters (TLD) in the CTDI phantoms and compared with the computed dose profiles. The in-plane dose distributions were simulated and compared with TLD measurements in an Alderson-Rando phantom. The calculated dose values were generally within 10% of measurements for all phantoms and all investigated conditions. Three-dimensional dose distributions can be accurately calculated with the MC tool for arbitrary scanners and protocols including tube current modulation schemes. The use of the tool has meanwhile also been extended to further scanners and to flat-detector CT.

Entities:  

Mesh:

Year:  2007        PMID: 18066555     DOI: 10.1007/s00330-007-0815-7

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  21 in total

1.  Organ dose conversion coefficients for external photon irradiation of male and female voxel models.

Authors:  M Zanki; U Fill; N Petoussi-Henss; D Regulla
Journal:  Phys Med Biol       Date:  2002-07-21       Impact factor: 3.609

2.  Semiempirical model for generating tungsten target x-ray spectra.

Authors:  D M Tucker; G T Barnes; D P Chakraborty
Journal:  Med Phys       Date:  1991 Mar-Apr       Impact factor: 4.071

3.  The effect of z overscanning on patient effective dose from multidetector helical computed tomography examinations.

Authors:  A Tzedakis; J Damilakis; K Perisinakis; J Stratakis; N Gourtsoyiannis
Journal:  Med Phys       Date:  2005-06       Impact factor: 4.071

Review 4.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

5.  Hyperfast parallel-beam and cone-beam backprojection using the cell general purpose hardware.

Authors:  Marc Kachelriess; Michael Knaup; Olivier Bockenbach
Journal:  Med Phys       Date:  2007-04       Impact factor: 4.071

6.  An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV.

Authors:  J M Boone; J A Seibert
Journal:  Med Phys       Date:  1997-11       Impact factor: 4.071

7.  CT scanner dosimetry.

Authors:  P C Shrimpton; S Edyvean
Journal:  Br J Radiol       Date:  1998-01       Impact factor: 3.039

8.  Radiation exposure in multi-slice versus single-slice spiral CT: results of a nationwide survey.

Authors:  G Brix; H D Nagel; G Stamm; R Veit; U Lechel; J Griebel; M Galanski
Journal:  Eur Radiol       Date:  2003-04-10       Impact factor: 5.315

9.  Conversion coefficients based on the VIP-Man anatomical model and EGS4.

Authors:  T C Chao; A Bozkurt; X G Xu
Journal:  Health Phys       Date:  2001-08       Impact factor: 1.316

10.  Estimation of effective doses to adult and pediatric patients from multislice computed tomography: A method based on energy imparted.

Authors:  Nicholas Theocharopoulos; John Damilakis; Kostas Perisinakis; Antonis Tzedakis; Apostolos Karantanas; Nicholas Gourtsoyiannis
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

View more
  40 in total

1.  Effect of CT scan protocols on x-ray-induced DNA double-strand breaks in blood lymphocytes of patients undergoing coronary CT angiography.

Authors:  M A Kuefner; S Grudzenski; J Hamann; S Achenbach; Michael Lell; K Anders; S A Schwab; L Häberle; M Löbrich; M Uder
Journal:  Eur Radiol       Date:  2010-07-13       Impact factor: 5.315

2.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

3.  Volume-of-interest imaging of the inner ear in a human temporal bone specimen using a robot- driven C-arm flat panel detector CT system.

Authors:  D Kolditz; T Struffert; Y Kyriakou; A Bozzato; A Dörfler; W A Kalender
Journal:  AJNR Am J Neuroradiol       Date:  2011-08-11       Impact factor: 3.825

4.  Image quality and dose optimisation for infant CT using a paediatric phantom.

Authors:  Jack W Lambert; Andrew S Phelps; Jesse L Courtier; Robert G Gould; John D MacKenzie
Journal:  Eur Radiol       Date:  2015-08-26       Impact factor: 5.315

Review 5.  Dual-source cardiac computed tomography: image quality and dose considerations.

Authors:  Stephan Achenbach; Katharina Anders; Willi A Kalender
Journal:  Eur Radiol       Date:  2008-02-26       Impact factor: 5.315

6.  Variability of surface and center position radiation dose in MDCT: Monte Carlo simulations using CTDI and anthropomorphic phantoms.

Authors:  Di Zhang; Ali S Savandi; John J Demarco; Chris H Cagnon; Erin Angel; Adam C Turner; Dianna D Cody; Donna M Stevens; Andrew N Primak; Cynthia H McCollough; Michael F McNitt-Gray
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

7.  Monte Carlo calculation of patient organ doses from computed tomography.

Authors:  Takeshi Oono; Fujio Araki; Shoya Tsuduki; Keiichi Kawasaki
Journal:  Radiol Phys Technol       Date:  2013-11-30

8.  CT dose index and patient dose: they are not the same thing.

Authors:  Cynthia H McCollough; Shuai Leng; Lifeng Yu; Dianna D Cody; John M Boone; Michael F McNitt-Gray
Journal:  Radiology       Date:  2011-05       Impact factor: 11.105

9.  Organ doses for reference adult male and female undergoing computed tomography estimated by Monte Carlo simulations.

Authors:  Choonsik Lee; Kwang Pyo Kim; Daniel Long; Ryan Fisher; Chris Tien; Steven L Simon; Andre Bouville; Wesley E Bolch
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

10.  The effect of iodine uptake on radiation dose absorbed by patient tissues in contrast enhanced CT imaging: Implications for CT dosimetry.

Authors:  Kostas Perisinakis; Antonis Tzedakis; Kostas Spanakis; Antonios E Papadakis; Adam Hatzidakis; John Damilakis
Journal:  Eur Radiol       Date:  2017-07-14       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.