Literature DB >> 2046607

Semiempirical model for generating tungsten target x-ray spectra.

D M Tucker1, G T Barnes, D P Chakraborty.   

Abstract

A semiempirical model for generating tungsten target x-ray spectra is presented. This model extends earlier work in two significant areas. First, both bremsstrahlung and characteristic x-ray production are assumed to occur at varying depths within the target. Second, optimal parameters for the model were determined from experimental spectra utilizing nonlinear least-squares techniques. As a result, good agreement is obtained between calculated and measured x-ray tube spectra and output for different target angles and a wide range of x-ray tube potentials. Such is not the case with previously published models.

Mesh:

Substances:

Year:  1991        PMID: 2046607     DOI: 10.1118/1.596709

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  31 in total

1.  Integrated model for estimating phosphor signal and noise transfer characteristics on medical images: application to CdPO3Cl:Mn phosphor screens.

Authors:  D Cavouras; I Kandarakis; G S Panayiotakis; C D Nomicos
Journal:  Med Biol Eng Comput       Date:  2002-05       Impact factor: 2.602

Review 2.  Application of polychromatic µCT for mineral density determination.

Authors:  W Zou; N Hunter; M V Swain
Journal:  J Dent Res       Date:  2010-09-21       Impact factor: 6.116

3.  Practical dose point-based methods to characterize dose distribution in a stationary elliptical body phantom for a cone-beam C-arm CT system.

Authors:  Jang-Hwan Choi; Dragos Constantin; Arundhuti Ganguly; Erin Girard; Richard L Morin; Robert L Dixon; Rebecca Fahrig
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

4.  Validation of a Monte Carlo tool for patient-specific dose simulations in multi-slice computed tomography.

Authors:  Paul Deak; Marcel van Straten; Paul C Shrimpton; Maria Zankl; Willi A Kalender
Journal:  Eur Radiol       Date:  2007-12-08       Impact factor: 5.315

5.  Oblique reconstructions in tomosynthesis. II. Super-resolution.

Authors:  Raymond J Acciavatti; Andrew D A Maidment
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

6.  Influence of difference in cross-sectional dose profile in a CTDI phantom on X-ray CT dose estimation: a Monte Carlo study.

Authors:  Tomonobu Haba; Shuji Koyama; Yoshihiro Ida
Journal:  Radiol Phys Technol       Date:  2013-11-24

7.  The x-ray light valve: a low-cost, digital radiographic imaging system--spatial resolution.

Authors:  Robert D MacDougall; Ivaylo Koprinarov; J A Rowlands
Journal:  Med Phys       Date:  2008-09       Impact factor: 4.071

8.  CT scanner x-ray spectrum estimation from transmission measurements.

Authors:  Xinhui Duan; Jia Wang; Lifeng Yu; Shuai Leng; Cynthia H McCollough
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

9.  Practical calibration curve of small-type optically stimulated luminescence (OSL) dosimeter for evaluation of entrance skin dose in the diagnostic X-ray region.

Authors:  Kazuki Takegami; Hiroaki Hayashi; Hiroki Okino; Natsumi Kimoto; Itsumi Maehata; Yuki Kanazawa; Tohru Okazaki; Ikuo Kobayashi
Journal:  Radiol Phys Technol       Date:  2015-05-15

10.  Segmentation-free x-ray energy spectrum estimation for computed tomography using dual-energy material decomposition.

Authors:  Wei Zhao; Lei Xing; Qiude Zhang; Qingguo Xie; Tianye Niu
Journal:  J Med Imaging (Bellingham)       Date:  2017-06-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.