Monte Carlo calculation of patient organ doses from computed tomography.

Takeshi Oono1, Fujio Araki, Shoya Tsuduki, Keiichi Kawasaki.   

Abstract

In this study, we aimed to evaluate quantitatively the patient organ dose from computed tomography (CT) using Monte Carlo calculations. A multidetector CT unit (Aquilion 16, TOSHIBA Medical Systems) was modeled with the GMctdospp (IMPS, Germany) software based on the EGSnrc Monte Carlo code. The X-ray spectrum and the configuration of the bowtie filter for the Monte Carlo modeling were determined from the chamber measurements for the half-value layer (HVL) of aluminum and the dose profile (off-center ratio, OCR) in air. The calculated HVL and OCR were compared with measured values for body irradiation with 120 kVp. The Monte Carlo-calculated patient dose distribution was converted to the absorbed dose measured by a Farmer chamber with a (60)Co calibration factor at the center of a CT water phantom. The patient dose was evaluated from dose-volume histograms for the internal organs in the pelvis. The calculated Al HVL was in agreement within 0.3% with the measured value of 5.2 mm. The calculated dose profile in air matched the measured value within 5% in a range of 15 cm from the central axis. The mean doses for soft tissues were 23.5, 23.8, and 27.9 mGy for the prostate, rectum, and bladder, respectively, under exposure conditions of 120 kVp, 200 mA, a beam pitch of 0.938, and beam collimation of 32 mm. For bones of the femur and pelvis, the mean doses were 56.1 and 63.6 mGy, respectively. The doses for bone increased by up to 2-3 times that of soft tissue, corresponding to the ratio of their mass-energy absorption coefficients.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24293361     DOI: 10.1007/s12194-013-0250-1

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  18 in total

1.  Performance evaluation of a multi-slice CT system.

Authors:  C H McCollough; F E Zink
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

2.  Characteristics of x-ray beams in two commercial multidetector computed tomography simulators: Monte Carlo simulations.

Authors:  Sangroh Kim; Haijun Song; Benjamin Movsas; Indrin J Chetty
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

3.  Restructuring CT dosimetry--a realistic strategy for the future Requiem for the pencil chamber.

Authors:  Robert L Dixon
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

4.  Efficiency improvements for ion chamber calculations in high energy photon beams.

Authors:  J Wulff; K Zink; I Kawrakow
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

5.  Organ doses for reference adult male and female undergoing computed tomography estimated by Monte Carlo simulations.

Authors:  Choonsik Lee; Kwang Pyo Kim; Daniel Long; Ryan Fisher; Chris Tien; Steven L Simon; Andre Bouville; Wesley E Bolch
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

6.  Estimated risks of radiation-induced fatal cancer from pediatric CT.

Authors:  D Brenner; C Elliston; E Hall; W Berdon
Journal:  AJR Am J Roentgenol       Date:  2001-02       Impact factor: 3.959

7.  Monte Carlo evaluation of kerma at a point for photon transport problems.

Authors:  J F Williamson
Journal:  Med Phys       Date:  1987 Jul-Aug       Impact factor: 4.071

8.  Comparison of two types of adult phantoms in terms of organ doses from diagnostic CT procedures.

Authors:  Haikuan Liu; Jianwei Gu; Peter F Caracappa; X George Xu
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

9.  The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulations.

Authors:  J Gu; B Bednarz; P F Caracappa; X G Xu
Journal:  Phys Med Biol       Date:  2009-04-08       Impact factor: 3.609

10.  Estimating radiation doses from multidetector CT using Monte Carlo simulations: effects of different size voxelized patient models on magnitudes of organ and effective dose.

Authors:  J J DeMarco; C H Cagnon; D D Cody; D M Stevens; C H McCollough; M Zankl; E Angel; M F McNitt-Gray
Journal:  Phys Med Biol       Date:  2007-04-17       Impact factor: 3.609

View more
  6 in total

1.  Determination and verification of the x-ray spectrum of a CT scanner.

Authors:  Ahmad Ibrahim Hassan; Martin Skalej; Helmut Schlattl; Christoph Hoeschen
Journal:  J Med Imaging (Bellingham)       Date:  2018-02-07

2.  A Monte Carlo study on quantifying the amount of dose reduction by shielding the superficial organs of an Iranian 11-year-old boy.

Authors:  Parisa Akhlaghi; Elie Hoseinian-Azghadi; Hashem Miri-Hakimabad; Laleh Rafat-Motavalli
Journal:  J Med Phys       Date:  2016 Oct-Dec

3.  Effect of ROI filtering in 3D cone-beam rotational angiography on organ dose and effective dose in cerebral investigations.

Authors:  Fabian Göpfert; Ralph Schmidt; Jörg Wulff; Klemens Zink
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

4.  Consideration of the usefulness of a size-specific dose estimate in pediatric CT examination.

Authors:  Takakiyo Tsujiguchi; Hideki Obara; Shuichi Ono; Yoko Saito; Ikuo Kashiwakura
Journal:  J Radiat Res       Date:  2018-07-01       Impact factor: 2.724

5.  Investigation of Eye Lens Dose Estimate based on AAPM Report 293 in Head Computed Tomography.

Authors:  Choirul Anam; Winda Kusuma Dewi; Masdi Masdi; Freddy Haryanto; Toshioh Fujibuchi; Geoff Dougherty
Journal:  J Biomed Phys Eng       Date:  2021-10-01

6.  Direct measurement of radiation exposure dose to individual organs during diagnostic computed tomography examination.

Authors:  Kazuta Yamashita; Kosaku Higashino; Hiroaki Hayashi; Kazuki Takegami; Fumio Hayashi; Yoshihiro Tsuruo; Koichi Sairyo
Journal:  Sci Rep       Date:  2021-03-08       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.