Literature DB >> 11480875

Conversion coefficients based on the VIP-Man anatomical model and EGS4.

T C Chao1, A Bozkurt, X G Xu.   

Abstract

A new set of conversion coefficients from kerma free-in-air to absorbed dose and kerma free-in-air to "effective VIP-Man dose" has been calculated for external monoenergetic photon beams from 10 keV to 10 MeV using an image-based whole-body anatomical model. This model, called VIP-Man, was recently developed at Rensselaer from the high-resolution color images of the National Library of Medicine's Visible Human Project. An EGS4-based Monte Carlo user code, named EGS4-VLSI, was developed to efficiently process the extremely large image data in VIP-Man. Irradiation conditions include anterior-posterior, posterior-anterior, right lateral, left lateral, rotational, and isotropic geometries. Conversion coefficients from this study are compared with those obtained from two mathematical models, ADAM and EVA. "Effective VIP-Man doses" differ from the previously reported effective dose results by 10%-50% for photons between 100 keV and 10 MeV. Discrepancies are more significant at lower energies and for individual organ doses. Since VIP-Man is a realistic model that contains several tissues that were not previously defined well (or not available) in other models, the reported results offer an opportunity to improve the existing dosimetric data and the mathematical models.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11480875     DOI: 10.1097/00004032-200108000-00010

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  8 in total

1.  Validation of a Monte Carlo tool for patient-specific dose simulations in multi-slice computed tomography.

Authors:  Paul Deak; Marcel van Straten; Paul C Shrimpton; Maria Zankl; Willi A Kalender
Journal:  Eur Radiol       Date:  2007-12-08       Impact factor: 5.315

2.  Advances in Computational Human Phantoms and Their Applications in Biomedical Engineering - A Topical Review.

Authors:  Wolfgang Kainz; Esra Neufeld; Wesley E Bolch; Christian G Graff; Chan Hyeong Kim; Niels Kuster; Bryn Lloyd; Tina Morrison; Paul Segars; Yeon Soo Yeom; Maria Zankl; X George Xu; Benjamin M W Tsui
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-01

3.  Monte Carlo simulations of adult and pediatric computed tomography exams: validation studies of organ doses with physical phantoms.

Authors:  Daniel J Long; Choonsik Lee; Christopher Tien; Ryan Fisher; Matthew R Hoerner; David Hintenlang; Wesley E Bolch
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

4.  BODY SIZE-SPECIFIC EFFECTIVE DOSE CONVERSION COEFFICIENTS FOR CT SCANS.

Authors:  Anna Romanyukha; Les Folio; Stephanie Lamart; Steven L Simon; Choonsik Lee
Journal:  Radiat Prot Dosimetry       Date:  2016-01-10       Impact factor: 0.972

Review 5.  An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history.

Authors:  X George Xu
Journal:  Phys Med Biol       Date:  2014-08-21       Impact factor: 3.609

6.  Extension of RPI-adult male and female computational phantoms to obese patients and a Monte Carlo study of the effect on CT imaging dose.

Authors:  Aiping Ding; Matthew M Mille; Tianyu Liu; Peter F Caracappa; X George Xu
Journal:  Phys Med Biol       Date:  2012-04-05       Impact factor: 3.609

Review 7.  Voxel-based computational models of real human anatomy: a review.

Authors:  Martin Caon
Journal:  Radiat Environ Biophys       Date:  2004-01-17       Impact factor: 1.925

8.  Development of a geometry-based respiratory motion-simulating patient model for radiation treatment dosimetry.

Authors:  Juying Zhang; George X Xu; Chengyu Shi; Martin Fuss
Journal:  J Appl Clin Med Phys       Date:  2008-01-21       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.