Literature DB >> 28710576

The effect of iodine uptake on radiation dose absorbed by patient tissues in contrast enhanced CT imaging: Implications for CT dosimetry.

Kostas Perisinakis1,2, Antonis Tzedakis3, Kostas Spanakis4, Antonios E Papadakis3, Adam Hatzidakis4,5, John Damilakis6,3.   

Abstract

OBJECTIVES: To investigate the effect of iodine uptake on tissue/organ absorbed doses from CT exposure and its implications in CT dosimetry.
METHODS: The contrast-induced CT number increase of several radiosensitive tissues was retrospectively determined in 120 CT examinations involving both non-enhanced and contrast-enhanced CT imaging. CT images of a phantom containing aqueous solutions of varying iodine concentration were obtained. Plots of the CT number increase against iodine concentration were produced. The clinically occurring iodine tissue uptake was quantified by attributing recorded CT number increase to a certain concentration of aqueous iodine solution. Clinically occurring iodine uptake was represented in mathematical anthropomorphic phantoms. Standard 120 kV CT exposures were simulated using Monte Carlo methods and resulting organ doses were derived for non-enhanced and iodine contrast-enhanced CT imaging.
RESULTS: The mean iodine uptake range during contrast-enhanced CT imaging was found to be 0.02-0.46% w/w for the investigated tissues, while the maximum value recorded was 0.82% w/w. For the same CT exposure, iodinated tissues were found to receive higher radiation dose than non-iodinated tissues, with dose increase exceeding 100% for tissues with high iodine uptake.
CONCLUSIONS: Administration of iodinated contrast medium considerably increases radiation dose to tissues from CT exposure. KEY-POINTS: • Radiation absorption ability of organs/tissues is considerably affected by iodine uptake • Iodinated organ/tissues may absorb up to 100 % higher radiation dose • Compared to non-enhanced, contrast-enhanced CT may deliver higher dose to patient tissues • CT dosimetry of contrast-enhanced CT imaging should encounter tissue iodine uptake.

Entities:  

Keywords:  CT imaging; Contrast media; Iodine; Radiation absorption; Radiation dose

Mesh:

Substances:

Year:  2017        PMID: 28710576     DOI: 10.1007/s00330-017-4970-1

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  19 in total

1.  Robust calculation of effective atomic numbers: the Auto-Z(eff) software.

Authors:  M L Taylor; R L Smith; F Dossing; R D Franich
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

Review 2.  Intravenous contrast medium administration and scan timing at CT: considerations and approaches.

Authors:  Kyongtae T Bae
Journal:  Radiology       Date:  2010-07       Impact factor: 11.105

3.  The effect of z overscanning on patient effective dose from multidetector helical computed tomography examinations.

Authors:  A Tzedakis; J Damilakis; K Perisinakis; J Stratakis; N Gourtsoyiannis
Journal:  Med Phys       Date:  2005-06       Impact factor: 4.071

Review 4.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

5.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

6.  Validation of a Monte Carlo tool for patient-specific dose simulations in multi-slice computed tomography.

Authors:  Paul Deak; Marcel van Straten; Paul C Shrimpton; Maria Zankl; Willi A Kalender
Journal:  Eur Radiol       Date:  2007-12-08       Impact factor: 5.315

7.  Evaluation of a patient-specific Monte Carlo software for CT dosimetry.

Authors:  Marios Myronakis; Kostas Perisinakis; Antonis Tzedakis; Sofia Gourtsoyianni; John Damilakis
Journal:  Radiat Prot Dosimetry       Date:  2009-03-27       Impact factor: 0.972

Review 8.  Reducing radiation dose in body CT: a primer on dose metrics and key CT technical parameters.

Authors:  Pierre D Maldjian; Alice R Goldman
Journal:  AJR Am J Roentgenol       Date:  2013-04       Impact factor: 3.959

9.  Normal organ weights in men: part II-the brain, lungs, liver, spleen, and kidneys.

Authors:  D Kimberley Molina; Vincent J M DiMaio
Journal:  Am J Forensic Med Pathol       Date:  2012-12       Impact factor: 0.921

10.  Managing patient dose in multi-detector computed tomography(MDCT). ICRP Publication 102.

Authors:  J Valentin
Journal:  Ann ICRP       Date:  2007
View more
  9 in total

1.  Radiation burden and associated cancer risk for a typical population to be screened for lung cancer with low-dose CT: A phantom study.

Authors:  Kostas Perisinakis; Ioannis Seimenis; Antonis Tzedakis; Apostolos Karantanas; John Damilakis
Journal:  Eur Radiol       Date:  2018-04-12       Impact factor: 5.315

2.  Contrast-enhanced or noncontrast CT for renal colic: utilizing urinalysis and patient history of urolithiasis to decide.

Authors:  Vishal Desai; Mougnyan Cox; Sandeep Deshmukh; Christopher G Roth
Journal:  Emerg Radiol       Date:  2018-04-20

3.  Performance evaluation of using shorter contrast injection and 70 kVp with deep learning image reconstruction for reduced contrast medium dose and radiation dose in coronary CT angiography for children: a pilot study.

Authors:  Jihang Sun; Haoyan Li; Jianying Li; Yongli Cao; Zuofu Zhou; Michelle Li; Yun Peng
Journal:  Quant Imaging Med Surg       Date:  2021-09

4.  Radiomics Study for Differentiating Focal Hepatic Lesions Based on Unenhanced CT Images.

Authors:  Xitong Zhao; Pan Liang; Liuliang Yong; Yan Jia; Jianbo Gao
Journal:  Front Oncol       Date:  2022-04-27       Impact factor: 5.738

5.  Inhibition of microRNA-875-5p promotes radioiodine uptake in poorly differentiated thyroid carcinoma cells by upregulating sodium-iodide symporter.

Authors:  Y Tang; X Meng; X Yu; H Shang; S Chen; L Liao; J Dong
Journal:  J Endocrinol Invest       Date:  2019-10-14       Impact factor: 5.467

6.  Computed Tomography Pulmonary Angiography during Pregnancy: Radiation Dose of Commonly Used Protocols and the Effect of Scan Length Optimization.

Authors:  Babs M F Hendriks; Roald S Schnerr; Gianluca Milanese; Cécile R L P N Jeukens; Sandra Niesen; Nienke G Eijsvoogel; Joachim E Wildberger; Marco Das
Journal:  Korean J Radiol       Date:  2019-02       Impact factor: 3.500

7.  Decreasing the radiation dose for contrast-enhanced abdominal spectral CT with a half contrast dose: a matched-pair comparison with a 120 kVp protocol.

Authors:  Daisuke Sakabe; Takeshi Nakaura; Seitaro Oda; Masafumi Kidoh; Daisuke Utsunomiya; R T Masahiro Hatemura; Yoshinori Funama
Journal:  BJR Open       Date:  2020-12-11

8.  Probability of receiving a high cumulative radiation dose and primary clinical indication of CT examinations: a 5-year observational cohort study.

Authors:  Cécile R L P N Jeukens; Hub Boere; Bart A J M Wagemans; Patty J Nelemans; Estelle C Nijssen; Rebecca Smith-Bindman; Joachim E Wildberger; Anna M Sailer
Journal:  BMJ Open       Date:  2021-01-17       Impact factor: 2.692

9.  The presence of contrast agent increases organ radiation dose in contrast-enhanced CT.

Authors:  Mahta Mazloumi; Gert Van Gompel; Veerle Kersemans; Johan de Mey; Nico Buls
Journal:  Eur Radiol       Date:  2021-03-30       Impact factor: 5.315

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.