Literature DB >> 18004568

Navigated non-image-based positioning of the acetabulum during total hip replacement.

Jean-Yves Jenny1, Cyril Boeri, Jean-Claude Dosch, Marius Uscatu, Eugen Ciobanu.   

Abstract

We tested the hypothesis that the non-image-based navigation system used in our department was able to measure accurately the 3D positioning of the acetabular cup of a total hip replacement (THR) and to increase the accuracy of its implantation during THR. We studied 50 consecutive navigated implantations of a THR and compared the intra-operative measurement of the cup by the navigation system to the post-operative measurement by computed tomography (CT) scan. The mean difference between the navigated and CT scan measurements for cup inclination was 2 degrees . The mean difference between the navigated and CT-scan measurements for cup flexion was 4 degrees . These differences were significant but considered to be clinically irrelevant in most cases. A total of 73% of the cases were within the safe zone defined prior to the study. The non-image-based system used allows a precise orientation of the cup during THR.

Mesh:

Year:  2007        PMID: 18004568      PMCID: PMC2899209          DOI: 10.1007/s00264-007-0479-6

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  24 in total

1.  Position of the acetabular cup -- accuracy of radiographic calculation compared to CT-based measurement.

Authors:  Thomas Kalteis; Martin Handel; Thomas Herold; Lars Perlick; Christian Paetzel; Joachim Grifka
Journal:  Eur J Radiol       Date:  2005-11-11       Impact factor: 3.528

Review 2.  OrthoPilot total hip arthroplasty workflow and surgery.

Authors:  Hartmuth Kiefer; Aneis Othman
Journal:  Orthopedics       Date:  2005-10       Impact factor: 1.390

3.  Cup alignment error model for total hip arthroplasty.

Authors:  Alon Wolf; Anthony M Digioia; Andrew B Mor; Branislav Jaramaz
Journal:  Clin Orthop Relat Res       Date:  2005-08       Impact factor: 4.176

4.  Computer navigation of the acetabular component: a cadaver reliability study.

Authors:  J M F Spencer; R E Day; K E Sloan; R J Beaver
Journal:  J Bone Joint Surg Br       Date:  2006-07

5.  Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation?

Authors:  T Kalteis; M Handel; H Bäthis; L Perlick; M Tingart; J Grifka
Journal:  J Bone Joint Surg Br       Date:  2006-02

6.  Estimation of pelvic tilt on anteroposterior X-rays--a comparison of six parameters.

Authors:  M Tannast; S B Murphy; F Langlotz; S E Anderson; K A Siebenrock
Journal:  Skeletal Radiol       Date:  2005-12-20       Impact factor: 2.199

7.  Computed tomography measurement of the accuracy of component version in total hip arthroplasty.

Authors:  Andrew P Wines; David McNicol
Journal:  J Arthroplasty       Date:  2006-08       Impact factor: 4.757

8.  How does soft tissue distribution affect anteversion accuracy of the palpation procedure in image-free acetabular cup navigation? An ultrasonographic assessment.

Authors:  Jens A Richolt; Harald Effenberger; Markus E Rittmeister
Journal:  Comput Aided Surg       Date:  2005-03

Review 9.  Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component.

Authors:  R Biedermann; A Tonin; M Krismer; F Rachbauer; G Eibl; B Stöckl
Journal:  J Bone Joint Surg Br       Date:  2005-06

10.  The frontal pelvic plane provides a valid reference system for implantation of the acetabular cup: spatial orientation of the pelvis in different positions.

Authors:  Eckart Mayr; Oliver Kessler; Alexandra Prassl; Franz Rachbauer; Martin Krismer; Michael Nogler
Journal:  Acta Orthop       Date:  2005-12       Impact factor: 3.717

View more
  10 in total

1.  [Principles and new concepts in computer-navigated total hip arthroplasty].

Authors:  T Renkawitz; M Wörner; E Sendtner; M Weber; P Lechler; J Grifka
Journal:  Orthopade       Date:  2011-12       Impact factor: 1.087

2.  Accuracy of computer navigation for acetabular component placement in THA.

Authors:  James A Ryan; Amir A Jamali; William L Bargar
Journal:  Clin Orthop Relat Res       Date:  2009-07-24       Impact factor: 4.176

3.  Effect of improved navigation performance on the accuracy of implant placement in total hip arthroplasty with a CT-based navigation system.

Authors:  Ichiro Nakahara; Takayuki Kyo; Yasuo Kuroda; Hidenobu Miki
Journal:  J Artif Organs       Date:  2018-04-02       Impact factor: 1.731

4.  Image-Less THA Cup Navigation in Clinical Routine Setup: Individual Adjustments, Accuracy, Precision, and Robustness.

Authors:  Corinne A Zurmühle; Benjamin Zickmantel; Matthias Christen; Bernhard Christen; Guoyan Zheng; Joseph M Schwab; Moritz Tannast; Simon D Steppacher
Journal:  Medicina (Kaunas)       Date:  2022-06-20       Impact factor: 2.948

5.  Lewinnek Safe Zone References are Frequently Misquoted.

Authors:  Aonnicha Burapachaisri; Ameer Elbuluk; Edem Abotsi; Jim Pierrepont; Seth A Jerabek; Aaron J Buckland; Jonathan M Vigdorchik
Journal:  Arthroplast Today       Date:  2020-11-26

6.  Does computer-assisted surgery benefit leg length restoration in total hip replacement? Navigation versus conventional freehand.

Authors:  Alfonso Manzotti; Pietro Cerveri; Elena De Momi; Chris Pullen; Norberto Confalonieri
Journal:  Int Orthop       Date:  2009-11-11       Impact factor: 3.075

7.  Accuracy of acetabular cup positioning using imageless navigation.

Authors:  Erik Hohmann; Adam Bryant; Kevin Tetsworth
Journal:  J Orthop Surg Res       Date:  2011-08-10       Impact factor: 2.359

8.  Initial Results of an Acetabular Center Axis Registration Technique in Navigated Hip Arthroplasty with Deformed Acetabular Rims.

Authors:  Hiroshi Wada; Hajime Mishima; Tomohiro Yoshizawa; Hisashi Sugaya; Tomofumi Nishino; Masashi Yamazaki
Journal:  Open Orthop J       Date:  2016-03-22

9.  Cup implantation accuracy using the HipCOMPASS mechanical intraoperative support device.

Authors:  Ken Suda; Tomoyuki Ito; Dai Miyasaka; Norio Imai; Izumi Minato; Naoto Endo
Journal:  Springerplus       Date:  2016-06-18

10.  Accuracy of cup placement in total hip arthroplasty by means of a mechanical positioning device: a comprehensive cadaveric 3d analysis of 16 specimens.

Authors:  Arthur J Kievit; Johannes G G Dobbe; Wouter H Mallee; Leendert Blankevoort; Geert J Streekstra; Matthias U Schafroth
Journal:  Hip Int       Date:  2019-09-11       Impact factor: 2.135

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.