Literature DB >> 19629609

Accuracy of computer navigation for acetabular component placement in THA.

James A Ryan1, Amir A Jamali, William L Bargar.   

Abstract

The accuracy and precision of any computer-aided surgical device is critical to its utility. We asked the following question: how accurate and precise are the values measured by an imageless computer navigation system as compared with those measured using postoperative CT scans? Twenty-five patients (26 hips) underwent primary THA using an imageless computer navigation system for placement of the acetabular component. Inclination and anteversion were measured in the operative coordinate system as defined by Murray. Accuracy, precision, and bias were computed, and Bland-Altman analysis was used to assess levels of agreement. The accuracy (mean +/- standard deviation of the absolute difference between computer-assisted navigation and CT) was 1.8 degrees +/- 1.2 degrees for inclination and 2.0 degrees +/- 2.0 degrees for anteversion. Precision was 3.4 degrees for inclination and 5.5 degrees for anteversion. Bias was 0.52 degrees for inclination and 0.35 degrees for anteversion. Limits of agreement were 4.26 degrees for inclination and 5.58 degrees for anteversion. An imageless computer navigation system can precisely determine acetabular cup position.

Entities:  

Mesh:

Year:  2009        PMID: 19629609      PMCID: PMC2795805          DOI: 10.1007/s11999-009-1003-7

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  39 in total

1.  Comparison of a mechanical acetabular alignment guide with computer placement of the socket.

Authors:  Anthony M Digioia; Branislav Jaramaz; Anton Y Plakseychuk; James E Moody; Constantinos Nikou; Richard S Labarca; Timothy J Levison; Frederic Picard
Journal:  J Arthroplasty       Date:  2002-04       Impact factor: 4.757

Review 2.  Unstable total hip arthroplasty: detailed overview.

Authors:  D J Berry
Journal:  Instr Course Lect       Date:  2001

3.  Reduction in variability of acetabular cup abduction using computer assisted surgery: a prospective and randomized study.

Authors:  T Leenders; D Vandevelde; G Mahieu; R Nuyts
Journal:  Comput Aided Surg       Date:  2002

4.  Reduced variability of acetabular cup positioning with use of an imageless navigation system.

Authors:  Michael Nogler; Oliver Kessler; Alexandra Prassl; Bill Donnelly; Robert Streicher; John B Sledge; Martin Krismer
Journal:  Clin Orthop Relat Res       Date:  2004-09       Impact factor: 4.176

5.  The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios.

Authors:  D D D'Lima; A G Urquhart; K O Buehler; R H Walker; C W Colwell
Journal:  J Bone Joint Surg Am       Date:  2000-03       Impact factor: 5.284

6.  Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis.

Authors:  B M Jolles; P Zangger; P-F Leyvraz
Journal:  J Arthroplasty       Date:  2002-04       Impact factor: 4.757

7.  Computer-assisted cup placement techniques in total hip arthroplasty improve accuracy of placement.

Authors:  Brigitte M Jolles; Patrick Genoud; Pierre Hoffmeyer
Journal:  Clin Orthop Relat Res       Date:  2004-09       Impact factor: 4.176

8.  C-arm based navigation in total hip arthroplasty-background and clinical experience.

Authors:  Paul A Grützner; Guoyan Zheng; Ulrich Langlotz; Jan von Recum; Lutz P Nolte; Andreas Wentzensen; Karl-Heinz Widmer; Klaus Wendl
Journal:  Injury       Date:  2004-06       Impact factor: 2.586

9.  Joint replacement-total hip replacement with CT-based navigation.

Authors:  Karl-Heinz Widmer; Paul Alfred Grützner
Journal:  Injury       Date:  2004-06       Impact factor: 2.586

10.  The accuracy of free-hand cup positioning--a CT based measurement of cup placement in 105 total hip arthroplasties.

Authors:  G Saxler; A Marx; D Vandevelde; U Langlotz; M Tannast; M Wiese; U Michaelis; G Kemper; P A Grützner; R Steffen; M von Knoch; T Holland-Letz; K Bernsmann
Journal:  Int Orthop       Date:  2004-05-15       Impact factor: 3.075

View more
  29 in total

1.  [Principles and new concepts in computer-navigated total hip arthroplasty].

Authors:  T Renkawitz; M Wörner; E Sendtner; M Weber; P Lechler; J Grifka
Journal:  Orthopade       Date:  2011-12       Impact factor: 1.087

2.  A cost-effective surgical navigation solution for periacetabular osteotomy (PAO) surgery.

Authors:  Silvio Pflugi; Li Liu; Timo M Ecker; Steffen Schumann; Jennifer Larissa Cullmann; Klaus Siebenrock; Guoyan Zheng
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-08-02       Impact factor: 2.924

3.  Anteroposterior Radiographs Are More Accurate than Cross-Table Lateral Radiographs for Acetabular Anteversion Assessment: a Retrospective Cohort Study.

Authors:  Peter K Sculco; Alexander S McLawhorn; Kaitlin M Carroll; Benjamin A McArthur; David J Mayman
Journal:  HSS J       Date:  2015-10-19

4.  Fluoroscopy assessment during anterior minimally invasive hip replacement is more accurate than with the posterior approach.

Authors:  Weifeng Ji; Nathaniel Stewart
Journal:  Int Orthop       Date:  2015-05-10       Impact factor: 3.075

5.  Using acetabular fossa as a guide for anticipated inclination of uncemented cup in total hip replacement.

Authors:  Junwei Li; Xu Gao; Guanghui Yang; Yanru Zhang
Journal:  Int J Clin Exp Med       Date:  2015-01-15

6.  CORR Insights®: Does Robotic Milling For Stem Implantation in Cementless THA Result in Improved Outcomes Scores or Survivorship Compared with Hand Rasping? Results of a Randomized Trial at 10 Years.

Authors:  Michael Tanzer
Journal:  Clin Orthop Relat Res       Date:  2018-11       Impact factor: 4.176

7.  Evaluation of the accuracy of femoral component orientation by the CT-based fluoro-matched navigation system.

Authors:  Shinya Hayashi; Takayuki Nishiyama; Takaaki Fujishiro; Shingo Hashimoto; Noriyuki Kanzaki; Kotaro Nishida; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Int Orthop       Date:  2013-03-20       Impact factor: 3.075

8.  Effect of screw fixation on acetabular component alignment change in total hip arthroplasty.

Authors:  Takaaki Fujishiro; Shinya Hayashi; Noriyuki Kanzaki; Shingo Hashimoto; Nao Shibanuma; Masahiro Kurosaka
Journal:  Int Orthop       Date:  2014-01-11       Impact factor: 3.075

9.  Augmented marker tracking for peri-acetabular osteotomy surgery.

Authors:  Silvio Pflugi; Rakesh Vasireddy; Till Lerch; Timo M Ecker; Moritz Tannast; Nane Boemke; Klaus Siebenrock; Guoyan Zheng
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-11-29       Impact factor: 2.924

10.  Effect of improved navigation performance on the accuracy of implant placement in total hip arthroplasty with a CT-based navigation system.

Authors:  Ichiro Nakahara; Takayuki Kyo; Yasuo Kuroda; Hidenobu Miki
Journal:  J Artif Organs       Date:  2018-04-02       Impact factor: 1.731

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.