Literature DB >> 16056040

Cup alignment error model for total hip arthroplasty.

Alon Wolf1, Anthony M Digioia, Andrew B Mor, Branislav Jaramaz.   

Abstract

Almost all computer-assisted orthopaedic surgery systems that rely on the anterior pelvic plane definition, such as in computed tomography and magnetic resonance image-based, fluoroscopy-based, and nonimage total hip replacement approaches, are derived from identifying two pairs of pelvic bony landmarks: anterior superior iliac spines and the pubic tubercles. Although these systems strive to achieve cup alignment accuracy of approximately 1 degree, even a minor failure to correctly identify these anatomic landmarks can lead to higher inaccuracies in the final cup alignment. This study shows how to examine the effects of these inaccuracies on the final acetabular cup implant orientation during total hip replacement by generating a kinematic model, which then is simulated. Simulation results indicate that, for example, a total error of 4 mm in measuring the anterior superior iliac spine and the pubic tubercles would result in a final cup orientation of 47 degrees and 27 degrees in abduction and version respectively, resulting in a 2 degrees abduction error and 7 degrees error in version when targeting 45 degrees abduction and 20 degrees version results. These calculations can be repeated for any error values.

Entities:  

Mesh:

Year:  2005        PMID: 16056040     DOI: 10.1097/01.blo.0000164027.06880.3a

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  22 in total

1.  MyHip: supporting planning and surgical guidance for a better total hip arthroplasty : A pilot study.

Authors:  Jérôme Schmid; Christophe Chênes; Sylvain Chagué; Pierre Hoffmeyer; Panayiotis Christofilopoulos; Massimiliano Bernardoni; Caecilia Charbonnier
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-04-01       Impact factor: 2.924

2.  Navigated non-image-based positioning of the acetabulum during total hip replacement.

Authors:  Jean-Yves Jenny; Cyril Boeri; Jean-Claude Dosch; Marius Uscatu; Eugen Ciobanu
Journal:  Int Orthop       Date:  2007-11-13       Impact factor: 3.075

3.  Six sigma analysis of minimally invasive acetabular arthroplasty: a preliminary investigation.

Authors:  David A Heck; James B Stiehl
Journal:  Clin Orthop Relat Res       Date:  2009-05-22       Impact factor: 4.176

Review 4.  Imaging and navigation measurement of acetabular component position in THA.

Authors:  Zhinian Wan; Aamer Malik; Branislav Jaramaz; Lisa Chao; Lawrence D Dorr
Journal:  Clin Orthop Relat Res       Date:  2008-11-01       Impact factor: 4.176

5.  Accuracy of computer navigation for acetabular component placement in THA.

Authors:  James A Ryan; Amir A Jamali; William L Bargar
Journal:  Clin Orthop Relat Res       Date:  2009-07-24       Impact factor: 4.176

6.  The 2008 Frank Stinchfield award: variation in postoperative pelvic tilt may confound the accuracy of hip navigation systems.

Authors:  Sebastien Parratte; Mark W Pagnano; Krista Coleman-Wood; Kenton R Kaufman; Daniel J Berry
Journal:  Clin Orthop Relat Res       Date:  2008-10-02       Impact factor: 4.176

7.  Pelvic flexion measurement from lateral projection radiographs is clinically reliable.

Authors:  Norio Imai; Tomoyuki Ito; Ken Suda; Dai Miyasaka; Naoto Endo
Journal:  Clin Orthop Relat Res       Date:  2013-01-03       Impact factor: 4.176

Review 8.  Radiographic assessment of the cup orientation after total hip arthroplasty: a literature review.

Authors:  Jing-Xin Zhao; Xiu-Yun Su; Zhe Zhao; Ruo-Xiu Xiao; Li-Cheng Zhang; Pei-Fu Tang
Journal:  Ann Transl Med       Date:  2020-02

9.  Acetabular orientation variability and symmetry based on CT scans of adults.

Authors:  Omri Lubovsky; Eran Peleg; Leo Joskowicz; Meir Liebergall; Amal Khoury
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-08-03       Impact factor: 2.924

Review 10.  Navigated cup implantation in hip arthroplasty.

Authors:  Johannes Beckmann; Dirk Stengel; Markus Tingart; Jürgen Götz; Joachim Grifka; Christian Lüring
Journal:  Acta Orthop       Date:  2009-10       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.