Migration of the Duraloc cup after 5 years.

Christoph Stihsen1, Christof Pabinger, Roman Radl, Peter Rehak, Reinhard Windhager.   

Abstract

The Duraloc cup is a frequently used metal-backed, porous-coated, hemispherical, press-fit acetabular component. Published data on loosening rates are contradictory. In this study we investigated migration patterns with computer-assisted Einzel-Bild-Roentgen-Analyse (EBRA) of 67 Duraloc 100 cups. Cup migration and clinical scores were analysed over a 5-year follow-up period. Median total migration of the Duraloc 100 cup was 1.21 mm at 5 years. Seventy-five percent of implants were radiologically stable at 2 years and 90% at 4 years. One cup loosened aseptically at 60 months, requiring revision. Cup diameters > or = 54 mm migrated significantly more than cups < 54 mm in diameter (p = 0.029 at 4 years). There was a significant correlation between high polyethylene wear and further migrating cups within the first post-operative year (p = 0.035 at 12 months). Our analysis revealed significantly higher wear in males (p = 0.029 at 4 years). Radiological loosening at two years could be calculated using receiver-operating characteristic curve analysis, and 1.2 mm as an adequate threshold value (sensitivity = 100%, specificity = 89%).

Entities:  

Mesh:

Year:  2007        PMID: 17609953      PMCID: PMC2898953          DOI: 10.1007/s00264-007-0405-y

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  22 in total

1.  Accuracy of the Nunn method in measuring acetabular cup migration.

Authors:  T Ilchmann; M A Freeman; B Mjöberg
Journal:  Ups J Med Sci       Date:  1992       Impact factor: 2.384

2.  Measurement accuracy in acetabular cup migration. A comparison of four radiologic methods versus roentgen stereophotogrammetric analysis.

Authors:  T Ilchmann; H Franzén; B Mjöberg; H Wingstrand
Journal:  J Arthroplasty       Date:  1992-06       Impact factor: 4.757

Review 3.  Fixation and loosening of hip prostheses. A review.

Authors:  B Mjöberg
Journal:  Acta Orthop Scand       Date:  1991-10

4.  The MOS 36-item short-form health survey (SF-36). I. Conceptual framework and item selection.

Authors:  J E Ware; C D Sherbourne
Journal:  Med Care       Date:  1992-06       Impact factor: 2.983

5.  Acetabular cup migration. Prediction of aseptic loosening.

Authors:  G W Stocks; M A Freeman; S J Evans
Journal:  J Bone Joint Surg Br       Date:  1995-11

6.  Early migration predicts late aseptic failure of hip sockets.

Authors:  M Krismer; B Stöckl; M Fischer; R Bauer; P Mayrhofer; M Ogon
Journal:  J Bone Joint Surg Br       Date:  1996-05

7.  Radiological demarcation of cemented sockets in total hip replacement.

Authors:  J G DeLee; J Charnley
Journal:  Clin Orthop Relat Res       Date:  1976 Nov-Dec       Impact factor: 4.176

8.  Total hip replacement with solid autologous femoral head graft for hip dysplasia.

Authors:  B Hintermann; E W Morscher
Journal:  Arch Orthop Trauma Surg       Date:  1995       Impact factor: 3.067

9.  EBRA: a method to measure migration of acetabular components.

Authors:  M Krismer; R Bauer; J Tschupik; P Mayrhofer
Journal:  J Biomech       Date:  1995-10       Impact factor: 2.712

10.  A prospective study of the migration of two acetabular components. PCA versus RM cups.

Authors:  M Krismer; M Fischer; P Mayrhofer; F Stöckl; C Bittner; C Trojer; B Stöckl
Journal:  Int Orthop       Date:  1994-02       Impact factor: 3.075

View more
  5 in total

1.  Migration characteristics and early clinical results of a novel-finned press-fit acetabular cup.

Authors:  Martin Kaipel; Anton Prenner; Sebastian Bachl; Sebastian Farr; Günter Sinz
Journal:  Wien Klin Wochenschr       Date:  2014-01-18       Impact factor: 1.704

2.  The effect of poly sterilization on wear, osteolysis and survivorship of a press-fit cup at 10-year followup.

Authors:  Charles A Engh; Cara C Powers; Henry Ho; Sarah E Beykirch-Padgett; Robert H Hopper; C Anderson Engh
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

3.  The Survivorship of the Uncemented Iso-Elastic Monoblock Acetabular Component at a Mean of 6-Year Follow-up.

Authors:  T E Snijders; J J Halma; J R A Massier; S M van Gaalen; A de Gast
Journal:  HSS J       Date:  2019-04-10

4.  Good mid-term results with the trident peripheral self-locking cup: a clinical evaluation and migration measurement with EBRA.

Authors:  Dietmar Dammerer; Philipp Blum; David Putzer; Andreas Tscholl; Michael C Liebensteiner; Martin Thaler
Journal:  Arch Orthop Trauma Surg       Date:  2020-11-09       Impact factor: 3.067

5.  Two-year radiologic assessment of the Pinnacle cup-a migration analysis with EBRA.

Authors:  Dietmar Dammerer; Alexander Ruzicka; Philipp Blum; David Putzer; Maximilian Liebsch; Julian Lair; Martin Thaler
Journal:  Arch Orthop Trauma Surg       Date:  2020-10-30       Impact factor: 3.067

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.