Literature DB >> 32015736

The Survivorship of the Uncemented Iso-Elastic Monoblock Acetabular Component at a Mean of 6-Year Follow-up.

T E Snijders1, J J Halma1, J R A Massier1, S M van Gaalen1,2, A de Gast1,2.   

Abstract

BACKGROUND: Aseptic loosening, caused by wear and osteolysis, is the most frequent reason for hip replacement revision in the UK. To prevent aseptic loosening, an acetabular component with vitamin E added to irradiated highly cross-linked polyethylene (HXLPE) was developed to reduce oxidative degradation. QUESTIONS/PURPOSES: A prior study of the vitamin E-blended HXLPE acetabular component after 2 years of follow-up reported no adverse reactions or abnormal mechanical behavior. To further examine this hypothesis of reducing wear and osteolysis, we sought to evaluate outcomes after 6-year follow-up.
METHODS: A cohort of 95 of the 112 initial patients (84.2%) completed the 6 years of follow-up after receiving a vitamin E-blended HXLPE acetabular component. Evaluation was performed in terms of clinical (visual analog scale [VAS] score, VAS score with weight-bearing, VAS score for satisfaction, and Harris Hip Score) and radiological (inclination, polar gap, radiolucencies, migration, and 2-D linear femoral head penetration rate) assessment.
RESULTS: The mean VAS score for patient satisfaction was 8.75 and the mean Harris Hip Score was 91.8. There were two revisions because of deep infections and one because of a peri-prosthetic femoral fracture. Two acetabular components migrated initially; however, delayed acetabular stabilization occurred. Both patients had good clinical scores at 72 months. The mean femoral head penetration rate was 0.036 mm/year.
CONCLUSIONS: This prospective cohort study has shown no adverse reactions concerning the vitamin E additive, promising wear rates, no signs of osteolysis, a 100% survival rate for aseptic loosening, and an all-cause survivorship percentage of 97.4% at 6 years of follow-up. © Hospital for Special Surgery 2019.

Entities:  

Keywords:  femoral head penetration; iso-elastic; monoblock cup; polyethylene; total hip arthroplasty; vitamin E

Year:  2019        PMID: 32015736      PMCID: PMC6973989          DOI: 10.1007/s11420-018-09658-8

Source DB:  PubMed          Journal:  HSS J        ISSN: 1556-3316


  17 in total

1.  Migration of the Duraloc cup after 5 years.

Authors:  Christoph Stihsen; Christof Pabinger; Roman Radl; Peter Rehak; Reinhard Windhager
Journal:  Int Orthop       Date:  2007-07-03       Impact factor: 3.075

2.  The results of the titanium-coated RM acetabular component at 20 years: a long-term follow-up of an uncemented primary total hip replacement.

Authors:  M Ihle; S Mai; D Pfluger; W Siebert
Journal:  J Bone Joint Surg Br       Date:  2008-10

3.  The determination of linear and angular penetration of the femoral head into the acetabular component as an assessment of wear in total hip replacement: a comparison of four computer-assisted methods.

Authors:  C H Geerdink; B Grimm; W Vencken; I C Heyligers; A J Tonino
Journal:  J Bone Joint Surg Br       Date:  2008-07

4.  The RM Pressfit vitamys: 5-year Swiss experience of the first 100 cups.

Authors:  Michael Wyatt; Jan Weidner; Dominik Pfluger; Martin Beck
Journal:  Hip Int       Date:  2017-01-20       Impact factor: 2.135

5.  An uncemented iso-elastic monoblock acetabular component: preliminary results.

Authors:  Jelle J Halma; Rienk Eshuis; H Charles Vogely; Steven M van Gaalen; Arthur de Gast
Journal:  J Arthroplasty       Date:  2014-11-27       Impact factor: 4.757

6.  Edge loading does not increase wear rates of ceramic-on-ceramic and metal-on-polyethylene articulations.

Authors:  Jelle J Halma; Jose Señaris; Daniel Delfosse; Reto Lerf; Thomas Oberbach; Steven M van Gaalen; Arthur de Gast
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2014-03-21       Impact factor: 3.368

Review 7.  Photodegradation and photostabilization of polymers, especially polystyrene: review.

Authors:  Emad Yousif; Raghad Haddad
Journal:  Springerplus       Date:  2013-08-23

Review 8.  Ultra-High Molecular Weight Polyethylene: Influence of the Chemical, Physical and Mechanical Properties on the Wear Behavior. A Review.

Authors:  Pierangiola Bracco; Anuj Bellare; Alessandro Bistolfi; Saverio Affatato
Journal:  Materials (Basel)       Date:  2017-07-13       Impact factor: 3.623

9.  The validation of the visual analogue scale for patient satisfaction after total hip arthroplasty.

Authors:  Roy B G Brokelman; Daniel Haverkamp; Corné van Loon; Annemiek Hol; Albert van Kampen; Rene Veth
Journal:  Eur Orthop Traumatol       Date:  2012-04-12

Review 10.  Wear of highly crosslinked polyethylene acetabular components.

Authors:  Stuart A Callary; Lucian B Solomon; Oksana T Holubowycz; David G Campbell; Zachary Munn; Donald W Howie
Journal:  Acta Orthop       Date:  2014-10-10       Impact factor: 3.717

View more
  3 in total

1.  Heterotopic ossification in primary total hip arthroplasty using the posterolateral compared to the direct lateral approach.

Authors:  J H J van Erp; J R A Massier; S Truijen; J E J Bekkers; T E Snijders; A de Gast
Journal:  Arch Orthop Trauma Surg       Date:  2021-02-03       Impact factor: 3.067

2.  A vitamin E blended highly cross-linked polyethylene acetabular cup results in less wear: 6-year results of a randomized controlled trial in 199 patients.

Authors:  Julie R A Massier; Joost H J Van Erp; Thom E Snijders; Arthur DE Gast
Journal:  Acta Orthop       Date:  2020-08-24       Impact factor: 3.717

3.  2-year results of an RCT of 2 uncemented isoelastic monoblock acetabular components: lower wear rate with vitamin E blended highly cross-linked polyethylene compared to ultra-high molecular weight polyethylene.

Authors:  Joost H J van Erp; Julie R A Massier; Jelle J Halma; Thom E Snijders; Arthur de Gast
Journal:  Acta Orthop       Date:  2020-02-26       Impact factor: 3.717

  3 in total