Accuracy of the Nunn method in measuring acetabular cup migration.

T Ilchmann1, M A Freeman, B Mjöberg.   

Abstract

The accuracy of the Nunn method in measuring acetabular component migration was compared with 3 other radiological methods and with roentgen stereophotogrammetry in 34 pelvic radiographs. The Nunn method seems to have the same or better accuracy than the other non-computerized methods, but less accuracy than the computerized EBRA method.