Two-year radiologic assessment of the Pinnacle cup-a migration analysis with EBRA.

Dietmar Dammerer1, Alexander Ruzicka1, Philipp Blum2, David Putzer3, Maximilian Liebsch1, Julian Lair1, Martin Thaler1.   

Abstract

INTRODUCTION: The most common cause of failure in total hip arthroplasty (THA) is aseptic loosening. Uncemented cup migration analysis by EBRA (Einzel-Bild-Roentgen-Analyse) has shown to be a good predictive indicator for early implant failure if the cup migrates more than 1 milimeter (mm) within the first 2 years after surgery. In this study, we investigated the migration behaviour of an uncemented press-fit cup after 2 years follow-up.
MATERIALS AND METHODS: Applying a retrospective study design, we reviewed all consecutive patients who received an uncemented press-fit cup at our Department between 2013 and 2018. A total of 484 patients were identified. We reviewed medical histories and performed radiological measurements using EBRA-Cup software. EBRA measurements and statistical investigations were performed by two independent investigators.
RESULTS: A total of 165 cups in 159 patients (female: 90; male: 69) met our inclusion criteria. Mean age at surgery was 66.7 (range 18.4-90.5) years. EBRA migration analysis showed a mean total migration of 0.7 mm (range 0.0-6.3) over our follow-up period of 2 years. Of the investigated cups, 53.2% showed less than 1 mm migration in the investigated follow-up period.
CONCLUSION: In conclusion, the Pinnacle cup used in our study provides low mean migration at final follow-up. Based on the assumption of secondary stabilization, good long-term outcome of the Pinnacle cup can be expected. TRIAL REGISTRATION NUMBER AND DATE OF REGISTRATION: Number: 20181024-1875; Date: 2018-09-20.

Entities:  

Keywords:  Cementless; Cup migration; Einzel-bild-röntgen-analyse (EBRA); Total hip arthroplasty

Mesh:

Year:  2020        PMID: 33128095      PMCID: PMC7815589          DOI: 10.1007/s00402-020-03648-4

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  11 in total

1.  Direct plain radiographic methods versus EBRA-Digital for measuring implant migration after total hip arthroplasty.

Authors:  Nicholas J Phillips; Ian Stockley; J Mark Wilkinson
Journal:  J Arthroplasty       Date:  2002-10       Impact factor: 4.757

2.  Mid-term results and migration behaviour of a ti-alloy cemented stem.

Authors:  R M Dominic Meek; John Michos; Peter Grigoris; David L Hamblen
Journal:  Int Orthop       Date:  2002-07-17       Impact factor: 3.075

3.  Measurement accuracy in acetabular cup migration. A comparison of four radiologic methods versus roentgen stereophotogrammetric analysis.

Authors:  T Ilchmann; H Franzén; B Mjöberg; H Wingstrand
Journal:  J Arthroplasty       Date:  1992-06       Impact factor: 4.757

4.  Modes of failure of a threaded acetabular cup : a radiographic study with EBRA of 42 revised cups.

Authors:  Thomas Ilchmann; Severin Neher; Franz Maurer; Kuno Weise
Journal:  Int Orthop       Date:  2006-06-08       Impact factor: 3.075

5.  Migration of the Duraloc cup after 5 years.

Authors:  Christoph Stihsen; Christof Pabinger; Roman Radl; Peter Rehak; Reinhard Windhager
Journal:  Int Orthop       Date:  2007-07-03       Impact factor: 3.075

6.  Five-year results of the uncemented RM pressfit cup clinical evaluation and migration measurements by EBRA.

Authors:  Tobias Wyss; Peter Kägi; Peter Mayrhofer; Hubert Nötzli; Dominik Pfluger; Karl Knahr
Journal:  J Arthroplasty       Date:  2013-03-20       Impact factor: 4.757

7.  Early migration characteristics of a 180° porous-coated cup with 1-mm press fit.

Authors:  Christoph Stihsen; Christopher Rath; Roman Radl; Ali A Saalabian; Wilfried Materna; Peter Rehak; Reinhard Windhager
Journal:  Arch Orthop Trauma Surg       Date:  2013-03-09       Impact factor: 3.067

8.  Accuracy of EBRA-cup measurements after reconstruction of severe acetabular defects at revision THR.

Authors:  John M Abrahams; Stuart A Callary; Sung W Jang; Joseph Hewitt; Donald W Howie; Lucian B Solomon
Journal:  J Orthop Res       Date:  2020-02-20       Impact factor: 3.494

9.  EBRA: a method to measure migration of acetabular components.

Authors:  M Krismer; R Bauer; J Tschupik; P Mayrhofer
Journal:  J Biomech       Date:  1995-10       Impact factor: 2.712

10.  Bipolar revision arthroplasty for failed threaded acetabular components: radiographic evaluation of cup migration.

Authors:  Yoshio Takatori; Setsuo Ninomiya; Takashige Umeyama; Motoi Yamamoto; Toru Moro; Kozo Nakamura
Journal:  J Orthop Sci       Date:  2002       Impact factor: 1.601

View more
  1 in total

1.  The intraoperative use of a calliper predicts leg length and offset after total hip arthroplasty. Component subsidence influences the leg length.

Authors:  Maliha Fansur; Nagib A Yurdi; Reinhard Stoewe
Journal:  J Orthop Surg Res       Date:  2021-07-03       Impact factor: 2.359

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.