Literature DB >> 17326169

Array-optimized composite pulse for excellent whole-brain homogeneity in high-field MRI.

Christopher M Collins1, Zhangwei Wang, Weihua Mao, Jieming Fang, Wanzhan Liu, Michael B Smith.   

Abstract

A number of methods to improve excitation homogeneity in high-field MRI have been proposed, and some of these methods rely on separate control of radiofrequency (RF) coils in a transmit array. In this work we combine accurate RF field calculations and the Bloch equation to demonstrate that by using a sequence of pulses with individually optimized current distributions (i.e., an array-optimized composite pulse), one can achieve remarkably homogeneous distributions of available signal intensity over the entire brain volume. This homogeneity is greater than that achievable using the same transmit array to produce either a single optimized (or RF shimmed) pulse or a single RF shimmed field distribution in a standard 90x-90y composite pulse arrangement. Simulations indicate that with a very simple array-optimized composite pulse, excellent whole-brain excitation homogeneity can be achieved at up to 600 MHz.

Mesh:

Year:  2007        PMID: 17326169      PMCID: PMC4040532          DOI: 10.1002/mrm.21172

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  10 in total

1.  Signal-to-noise ratio and absorbed power as functions of main magnetic field strength, and definition of "90 degrees " RF pulse for the head in the birdcage coil.

Authors:  C M Collins; M B Smith
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

Review 2.  Sensitivity and power deposition in a high-field imaging experiment.

Authors:  D I Hoult; D Phil
Journal:  J Magn Reson Imaging       Date:  2000-07       Impact factor: 4.813

3.  Effect of RF coil excitation on field inhomogeneity at ultra high fields: a field optimized TEM resonator.

Authors:  T S Ibrahim; R Lee; B A Baertlein; A M Abduljalil; H Zhu; P M Robitaille
Journal:  Magn Reson Imaging       Date:  2001-12       Impact factor: 2.546

4.  Multishot 3D slice-select tailored RF pulses for MRI.

Authors:  V Andrew Stenger; Fernando E Boada; Douglas C Noll
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

5.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

6.  Combination of optimized transmit arrays and some receive array reconstruction methods can yield homogeneous images at very high frequencies.

Authors:  Christopher M Collins; Wanzhan Liu; Bryan J Swift; Michael B Smith
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

7.  Small tip angle three-dimensional tailored radiofrequency slab-select pulse for reduced B1 inhomogeneity at 3 T.

Authors:  Suwit Saekho; Fernando E Boada; Douglas C Noll; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

8.  Transmit and receive transmission line arrays for 7 Tesla parallel imaging.

Authors:  Gregor Adriany; Pierre-Francois Van de Moortele; Florian Wiesinger; Steen Moeller; John P Strupp; Peter Andersen; Carl Snyder; Xiaoliang Zhang; Wei Chen; Klaas P Pruessmann; Peter Boesiger; Tommy Vaughan; Kāmil Uğurbil
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

9.  Calculations of B1 Distribution, Specific Energy Absorption Rate, and Intrinsic Signal-to-Noise Ratio for a Body-Size Birdcage Coil Loaded with Different Human Subjects at 64 and 128 MHz.

Authors:  W Liu; C M Collins; M B Smith
Journal:  Appl Magn Reson       Date:  2005-03       Impact factor: 0.831

10.  A three-dimensional spin-echo or inversion pulse.

Authors:  J M Pauly; B S Hu; S J Wang; D G Nishimura; A Macovski
Journal:  Magn Reson Med       Date:  1993-01       Impact factor: 4.668

  10 in total
  11 in total

1.  Cell-permeable MR contrast agents with increased intracellular retention.

Authors:  Paul J Endres; Keith W MacRenaris; Stefan Vogt; Thomas J Meade
Journal:  Bioconjug Chem       Date:  2008-09-20       Impact factor: 4.774

2.  Regularized estimation of magnitude and phase of multi-coil b1 field via Bloch-Siegert B1 mapping and coil combination optimizations.

Authors:  Feng Zhao; Jeffrey A Fessler; Steven M Wright; Douglas C Noll
Journal:  IEEE Trans Med Imaging       Date:  2014-06-09       Impact factor: 10.048

3.  Hepatic fat assessment using advanced Magnetic Resonance Imaging.

Authors:  Yong Pang; Baiying Yu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2012-09

4.  Quadrature transmit array design using single-feed circularly polarized patch antenna for parallel transmission in MR imaging.

Authors:  Yong Pang; Baiying Yu; Daniel B Vigneron; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02

5.  Calculation of radiofrequency electromagnetic fields and their effects in MRI of human subjects.

Authors:  Christopher M Collins; Zhangwei Wang
Journal:  Magn Reson Med       Date:  2011-03-04       Impact factor: 4.668

6.  Radiofrequency pulse designs for three-dimensional MRI providing uniform tipping in inhomogeneous B₁ fields.

Authors:  Hui Liu; Gerald B Matson
Journal:  Magn Reson Med       Date:  2011-04-26       Impact factor: 4.668

Review 7.  Numerical field calculations considering the human subject for engineering and safety assurance in MRI.

Authors:  Christopher M Collins
Journal:  NMR Biomed       Date:  2009-11       Impact factor: 4.044

8.  Improvement of Electromagnetic Field Distributions Using High Dielectric Constant (HDC) Materials for CTL-Spine MRI: Numerical Simulations and Experiments.

Authors:  Bu S Park; Brent McCright; Leonardo M Angelone; Amir Razjouyan; Sunder S Rajan
Journal:  IEEE Trans Electromagn Compat       Date:  2017-10       Impact factor: 2.006

9.  Numerical evaluation of image homogeneity, signal-to-noise ratio, and specific absorption rate for human brain imaging at 1.5, 3, 7, 10.5, and 14T in an 8-channel transmit/receive array.

Authors:  Zhipeng Cao; Joshua Park; Zang-Hee Cho; Christopher M Collins
Journal:  J Magn Reson Imaging       Date:  2014-06-27       Impact factor: 4.813

10.  Electrodynamic constraints on homogeneity and radiofrequency power deposition in multiple coil excitations.

Authors:  Riccardo Lattanzi; Daniel K Sodickson; Aaron K Grant; Yudong Zhu
Journal:  Magn Reson Med       Date:  2009-02       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.