Literature DB >> 8419739

A three-dimensional spin-echo or inversion pulse.

J M Pauly1, B S Hu, S J Wang, D G Nishimura, A Macovski.   

Abstract

In theory, multidimensional pulses can be designed to be selective in any number of dimensions. In practice, available gradient power has enforced a limit to two dimensions. We show here that three-dimensional pi pulses are feasible on commercial imaging machines provided that the range of off-resonance frequencies are limited.

Mesh:

Year:  1993        PMID: 8419739     DOI: 10.1002/mrm.1910290103

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  12 in total

1.  Three-dimensional tailored RF pulses for the reduction of susceptibility artifacts in T(*)(2)-weighted functional MRI.

Authors:  V A Stenger; F E Boada; D C Noll
Journal:  Magn Reson Med       Date:  2000-10       Impact factor: 4.668

2.  Multishot 3D slice-select tailored RF pulses for MRI.

Authors:  V Andrew Stenger; Fernando E Boada; Douglas C Noll
Journal:  Magn Reson Med       Date:  2002-07       Impact factor: 4.668

3.  Basic considerations on the impact of the coil array on the performance of Transmit SENSE.

Authors:  U Katscher; J Röhrs; P Börnert
Journal:  MAGMA       Date:  2005-02-11       Impact factor: 2.310

4.  Small tip angle three-dimensional tailored radiofrequency slab-select pulse for reduced B1 inhomogeneity at 3 T.

Authors:  Suwit Saekho; Fernando E Boada; Douglas C Noll; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

5.  Array-optimized composite pulse for excellent whole-brain homogeneity in high-field MRI.

Authors:  Christopher M Collins; Zhangwei Wang; Weihua Mao; Jieming Fang; Wanzhan Liu; Michael B Smith
Journal:  Magn Reson Med       Date:  2007-03       Impact factor: 4.668

Review 6.  Parallel magnetic resonance imaging.

Authors:  Ulrich Katscher; Peter Börnert
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

7.  Designing multichannel, multidimensional, arbitrary flip angle RF pulses using an optimal control approach.

Authors:  Dan Xu; Kevin F King; Yudong Zhu; Graeme C McKinnon; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2008-03       Impact factor: 4.668

8.  Joint Design of Excitation k-Space Trajectory and RF Pulse for Small-Tip 3D Tailored Excitation in MRI.

Authors:  Sun Hao; Jeffrey A Fessler; Douglas C Noll; Jon-Fredrik Nielsen
Journal:  IEEE Trans Med Imaging       Date:  2015-09-15       Impact factor: 10.048

9.  Parallel transmission RF pulse design for eddy current correction at ultra high field.

Authors:  Hai Zheng; Tiejun Zhao; Yongxian Qian; Tamer Ibrahim; Fernando Boada
Journal:  J Magn Reson       Date:  2012-03-28       Impact factor: 2.229

10.  Fast large-tip-angle multidimensional and parallel RF pulse design in MRI.

Authors:  William A Grissom; Dan Xu; Adam B Kerr; Jeffrey A Fessler; Douglas C Noll
Journal:  IEEE Trans Med Imaging       Date:  2009-05-12       Impact factor: 10.048