Calculation of radiofrequency electromagnetic fields and their effects in MRI of human subjects.

Christopher M Collins1, Zhangwei Wang.   

Abstract

Radiofrequency magnetic fields are critical to nuclear excitation and signal reception in magnetic resonance imaging. The interactions between these fields and human tissues in anatomical geometries results in a variety of effects regarding image integrity and safety of the human subject. In recent decades, numerical methods of calculation have been used increasingly to understand the effects of these interactions and aid in engineering better, faster, and safer equipment and methods. As magnetic resonance imaging techniques and technology have evolved through the years, so to have the requirements for meaningful interpretation of calculation results. Here, we review the basic physics of radiofrequency electromagnetics in magnetic resonance imaging and discuss a variety of ways radiofrequency field calculations are used in magnetic resonance imaging in engineering and safety assurance from simple systems and sequences through advanced methods of development for the future.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21381106      PMCID: PMC3078983          DOI: 10.1002/mrm.22845

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  64 in total

1.  Electromagnetic and thermal modeling of SAR and temperature fields in tissue due to an RF decoupling coil.

Authors:  J W Hand; R W Lau; J J Lagendijk; J Ling; M Burl; I R Young
Journal:  Magn Reson Med       Date:  1999-07       Impact factor: 4.668

2.  Simulation-based investigation of partially parallel imaging with a linear array at high accelerations.

Authors:  James A Bankson; Steven M Wright
Journal:  Magn Reson Med       Date:  2002-04       Impact factor: 4.668

3.  Manipulation of image intensity distribution at 7.0 T: passive RF shimming and focusing with dielectric materials.

Authors:  Qing X Yang; Weihua Mao; Jinghua Wang; Michael B Smith; Hao Lei; Xiaoliang Zhang; Kamil Ugurbil; Wei Chen
Journal:  J Magn Reson Imaging       Date:  2006-07       Impact factor: 4.813

4.  Proposed radiofrequency phased-array excitation scheme for homogenous and localized 7-Tesla whole-body imaging based on full-wave numerical simulations.

Authors:  Roney Abraham; Tamer S Ibrahim
Journal:  Magn Reson Med       Date:  2007-02       Impact factor: 4.668

5.  9.4T human MRI: preliminary results.

Authors:  Thomas Vaughan; Lance DelaBarre; Carl Snyder; Jinfeng Tian; Can Akgun; Devashish Shrivastava; Wanzahn Liu; Chris Olson; Gregor Adriany; John Strupp; Peter Andersen; Anand Gopinath; Pierre-Francois van de Moortele; Michael Garwood; Kamil Ugurbil
Journal:  Magn Reson Med       Date:  2006-12       Impact factor: 4.668

6.  Array-optimized composite pulse for excellent whole-brain homogeneity in high-field MRI.

Authors:  Christopher M Collins; Zhangwei Wang; Weihua Mao; Jieming Fang; Wanzhan Liu; Michael B Smith
Journal:  Magn Reson Med       Date:  2007-03       Impact factor: 4.668

7.  Electromagnetic fields of surface coil in vivo NMR at high frequencies.

Authors:  J R Keltner; J W Carlson; M S Roos; S T Wong; T L Wong; T F Budinger
Journal:  Magn Reson Med       Date:  1991-12       Impact factor: 4.668

Review 8.  Modelling the interaction of electromagnetic fields (10 MHz-10 GHz) with the human body: methods and applications.

Authors:  J W Hand
Journal:  Phys Med Biol       Date:  2008-07-24       Impact factor: 3.609

9.  Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions.

Authors:  Philip M Robson; Aaron K Grant; Ananth J Madhuranthakam; Riccardo Lattanzi; Daniel K Sodickson; Charles A McKenzie
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

10.  Experimental and numerical assessment of MRI-induced temperature change and SAR distributions in phantoms and in vivo.

Authors:  Sukhoon Oh; Andrew G Webb; Thomas Neuberger; BuSik Park; Christopher M Collins
Journal:  Magn Reson Med       Date:  2010-01       Impact factor: 4.668

View more
  36 in total

1.  Surface coil with reduced specific absorption rate for rat MRI at 7 T.

Authors:  Sergio E Solis-Najera; Rodrigo Martin; Fabian Vazquez; Alfredo O Rodriguez
Journal:  MAGMA       Date:  2015-10-08       Impact factor: 2.310

2.  A multichannel, real-time MRI RF power monitor for independent SAR determination.

Authors:  Abdel-Monem M El-Sharkawy; Di Qian; Paul A Bottomley; William A Edelstein
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

Review 3.  Implementation of a comprehensive MR safety course for medical students.

Authors:  Steffen Sammet; Christina L Sammet
Journal:  J Magn Reson Imaging       Date:  2015-07-14       Impact factor: 4.813

4.  Complex difference constrained compressed sensing reconstruction for accelerated PRF thermometry with application to MRI-induced RF heating.

Authors:  Zhipeng Cao; Sukhoon Oh; Ricardo Otazo; Christopher T Sica; Mark A Griswold; Christopher M Collins
Journal:  Magn Reson Med       Date:  2014-04-21       Impact factor: 4.668

Review 5.  Quantitative techniques for musculoskeletal MRI at 7 Tesla.

Authors:  Neal K Bangerter; Meredith D Taylor; Grayson J Tarbox; Antony J Palmer; Daniel J Park
Journal:  Quant Imaging Med Surg       Date:  2016-12

6.  Measurement of SAR-induced temperature increase in a phantom and in vivo with comparison to numerical simulation.

Authors:  Sukhoon Oh; Yeun-Chul Ryu; Giuseppe Carluccio; Christopher T Sica; Christopher M Collins
Journal:  Magn Reson Med       Date:  2013-06-26       Impact factor: 4.668

7.  Measurements of RF power reflected and radiated by multichannel transmit MR coils at 7T.

Authors:  Gerd Weidemann; Frank Seifert; Werner Hoffmann; Harald Pfeiffer; Reiner Seemann; Bernd Ittermann
Journal:  MAGMA       Date:  2016-04-02       Impact factor: 2.310

Review 8.  Magnetic-resonance-based electrical properties tomography: a review.

Authors:  Xiaotong Zhang; Jiaen Liu; Bin He
Journal:  IEEE Rev Biomed Eng       Date:  2014

9.  Measurements of RF heating during 3.0-T MRI of a pig implanted with deep brain stimulator.

Authors:  Krzysztof R Gorny; Michael F Presti; Stephan J Goerss; Sun C Hwang; Dong-Pyo Jang; Inyong Kim; Hoon-Ki Min; Yunhong Shu; Christopher P Favazza; Kendall H Lee; Matt A Bernstein
Journal:  Magn Reson Imaging       Date:  2012-12-07       Impact factor: 2.546

10.  High resolution (13)C MRI with hyperpolarized urea: in vivo T(2) mapping and (15)N labeling effects.

Authors:  Galen D Reed; Cornelius von Morze; Robert Bok; Bertram L Koelsch; Mark Van Criekinge; Kenneth J Smith; Peder E Z Larson; John Kurhanewicz; Daniel B Vigneron
Journal:  IEEE Trans Med Imaging       Date:  2013-10-25       Impact factor: 10.048

View more