Literature DB >> 21523819

Radiofrequency pulse designs for three-dimensional MRI providing uniform tipping in inhomogeneous B₁ fields.

Hui Liu1, Gerald B Matson.   

Abstract

Although high-field MRI offers increased signal-to-noise, the nonuniform tipping produced by conventional radiofrequency (RF) pulses leads to spatially dependent contrast and suboptimal signal-to-noise, thus complicating the interpretation of the MR images. For structural imaging, three-dimensional sequences that do not make use of frequency-selective RF pulses have become popular. Therefore, the aim of this research was to develop non-slice-selective (NSS) RF pulses with immunity to both amplitude of (excitation) RF field (B(1) ) inhomogeneity and resonance offset. To accomplish this, an optimization routine based on optimal control theory was used to design new NSS pulses with desired ranges of immunity to B(1) inhomogeneity and resonance offset. The design allows the phase of transverse magnetization produced by the pulses to vary. Although the emphasis is on shallow tip designs, new designs for 30°, 60°, 90°, and 180° NSS RF pulses are also provided. These larger tip angle pulses are compared with recently published NSS pulses. Evidence is presented that the pulses presented in this article have equivalent performance but are shorter than the recently published pulses. Although the NSS pulses generate higher specific absorption rates and larger magnetization transfer effects than the rectangular pulses they replace, they nevertheless show promise for three-dimensional MRI experiments at high field.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21523819      PMCID: PMC3269758          DOI: 10.1002/mrm.22913

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  20 in total

Review 1.  Sensitivity and power deposition in a high-field imaging experiment.

Authors:  D I Hoult; D Phil
Journal:  J Magn Reson Imaging       Date:  2000-07       Impact factor: 4.813

2.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

3.  Exploring the limits of broadband excitation and inversion pulses.

Authors:  Kyryl Kobzar; Thomas E Skinner; Navin Khaneja; Steffen J Glaser; Burkhard Luy
Journal:  J Magn Reson       Date:  2004-10       Impact factor: 2.229

4.  Reducing the duration of broadband excitation pulses using optimal control with limited RF amplitude.

Authors:  Thomas E Skinner; Timo O Reiss; Burkhard Luy; Navin Khaneja; Steffen J Glaser
Journal:  J Magn Reson       Date:  2004-03       Impact factor: 2.229

5.  Exploring the limits of RF shimming for high-field MRI of the human head.

Authors:  Weihua Mao; Michael B Smith; Christopher M Collins
Journal:  Magn Reson Med       Date:  2006-10       Impact factor: 4.668

6.  Array-optimized composite pulse for excellent whole-brain homogeneity in high-field MRI.

Authors:  Christopher M Collins; Zhangwei Wang; Weihua Mao; Jieming Fang; Wanzhan Liu; Michael B Smith
Journal:  Magn Reson Med       Date:  2007-03       Impact factor: 4.668

7.  Counteracting radio frequency inhomogeneity in the human brain at 7 Tesla using strongly modulating pulses.

Authors:  N Boulant; J-F Mangin; A Amadon
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

8.  Strongly modulating pulses for counteracting RF inhomogeneity at high fields.

Authors:  N Boulant; D Le Bihan; A Amadon
Journal:  Magn Reson Med       Date:  2008-09       Impact factor: 4.668

9.  An integrated program for amplitude-modulated RF pulse generation and re-mapping with shaped gradients.

Authors:  G B Matson
Journal:  Magn Reson Imaging       Date:  1994       Impact factor: 2.546

10.  Electrodynamic constraints on homogeneity and radiofrequency power deposition in multiple coil excitations.

Authors:  Riccardo Lattanzi; Daniel K Sodickson; Aaron K Grant; Yudong Zhu
Journal:  Magn Reson Med       Date:  2009-02       Impact factor: 4.668

View more
  4 in total

1.  Motion-robust cardiac B1+ mapping at 3T using interleaved bloch-siegert shifts.

Authors:  Sebastian Weingärtner; Fabian Zimmer; Gregory J Metzger; Kâmil Uğurbil; Pierre-Francois Van de Moortele; Mehmet Akçakaya
Journal:  Magn Reson Med       Date:  2016-09-07       Impact factor: 4.668

2.  Whole-brain arteriography and venography: Using improved velocity-selective saturation pulse trains.

Authors:  Wenbo Li; Feng Xu; Michael Schär; Jing Liu; Taehoon Shin; Yansong Zhao; Peter C M van Zijl; Bruce A Wasserman; Ye Qiao; Qin Qin
Journal:  Magn Reson Med       Date:  2017-08-10       Impact factor: 4.668

3.  Slice-selective excitation with B₁⁺-insensitive composite pulses.

Authors:  Jay Moore; Marcin Jankiewicz; Adam W Anderson; John C Gore
Journal:  J Magn Reson       Date:  2011-11-18       Impact factor: 2.229

4.  A novel spectrally selective fat saturation pulse design with robustness to B0 and B1 inhomogeneities: A demonstration on 3D T1-weighted breast MRI at 3 T.

Authors:  Feng Xu; Wenbo Li; Dapeng Liu; Dan Zhu; Michael Schär; Kelly Myers; Qin Qin
Journal:  Magn Reson Imaging       Date:  2020-10-29       Impact factor: 2.546

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.