Literature DB >> 10931564

Sensitivity and power deposition in a high-field imaging experiment.

D I Hoult1, D Phil.   

Abstract

Image signal-to-noise ratio and power dissipation are investigated theoretically up to 400 MHz. While the text is mathematical, the figures give insights into predictions. Hertz potential is introduced for probe modeling where charge separation cannot be ignored. Using a spherical geometry, the potential from current loops that would produce a homogeneous static B1 field is calculated; at high frequency it is shown to create an unnecessarily inhomogeneous field. However, a totally homogeneous field is shown to be unattainable. Boundary conditions are solved for circularly polarized fields, and strategies for limited shimming of the sample B1 field are then presented. A distinction is drawn between dielectric resonance and spatial field focusing. At high frequency, the region of maximum specific absorption is shown to move inside the sample and decrease. From the fields in both rotating frames, the signal-to-noise ratio is derived and compared with the traditional, low-frequency formulation. On average, it is mostly found to be slightly larger at high frequency. Nevertheless, the free induction decay is sometimes found to be annulled.

Mesh:

Year:  2000        PMID: 10931564     DOI: 10.1002/1522-2586(200007)12:1<46::aid-jmri6>3.0.co;2-d

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  121 in total

1.  Interventional loopless antenna at 7 T.

Authors:  Mehmet Arcan Ertürk; Abdel-Monem M El-Sharkawy; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2011-12-12       Impact factor: 4.668

2.  Investigation of multichannel phased array performance for fetal MR imaging on 1.5T clinical MR system.

Authors:  Ye Li; Yong Pang; Daniel Vigneron; Orit Glenn; Duan Xu; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2011-01-01

Review 3.  In vivo structural imaging of the cerebellum, the contribution of ultra-high fields.

Authors:  José P Marques; Rolf Gruetter; Wietske van der Zwaag
Journal:  Cerebellum       Date:  2012-06       Impact factor: 3.847

4.  Surface coil with reduced specific absorption rate for rat MRI at 7 T.

Authors:  Sergio E Solis-Najera; Rodrigo Martin; Fabian Vazquez; Alfredo O Rodriguez
Journal:  MAGMA       Date:  2015-10-08       Impact factor: 2.310

5.  7 Tesla quantitative hip MRI: T1, T2 and T2* mapping of hip cartilage in healthy volunteers.

Authors:  Andrea Lazik; Jens M Theysohn; Christina Geis; Sören Johst; Mark E Ladd; Harald H Quick; Oliver Kraff
Journal:  Eur Radiol       Date:  2015-08-28       Impact factor: 5.315

6.  An efficient design for birdcage probes dedicated to small-animal imaging experiments.

Authors:  M Lupu; J L Dimicoli; A Volk; J Mispelter
Journal:  MAGMA       Date:  2004-11-08       Impact factor: 2.310

7.  Advantages and pitfalls in 3T MR brain imaging: a pictorial review.

Authors:  Bernd L Schmitz; Andrik J Aschoff; Martin H K Hoffmann; Georg Grön
Journal:  AJNR Am J Neuroradiol       Date:  2005-10       Impact factor: 3.825

Review 8.  Whole-body MRI at high field: technical limits and clinical potential.

Authors:  Fritz Schick
Journal:  Eur Radiol       Date:  2005-01-27       Impact factor: 5.315

9.  Preoperative staging of rectal cancer: accuracy of 3-Tesla magnetic resonance imaging.

Authors:  Chan Kyo Kim; Seung Hoon Kim; Ho Kyung Chun; Woo-Yong Lee; Seong-Hyeon Yun; Sang-Yong Song; Dongil Choi; Hyo Keun Lim; Min Ju Kim; Jongmee Lee; Soon Jin Lee
Journal:  Eur Radiol       Date:  2006-01-17       Impact factor: 5.315

10.  Exploring the limits of RF shimming for high-field MRI of the human head.

Authors:  Weihua Mao; Michael B Smith; Christopher M Collins
Journal:  Magn Reson Med       Date:  2006-10       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.