Literature DB >> 24649430

Quadrature transmit array design using single-feed circularly polarized patch antenna for parallel transmission in MR imaging.

Yong Pang1, Baiying Yu1, Daniel B Vigneron1, Xiaoliang Zhang1.   

Abstract

Quadrature coils are often desired in MR applications because they can improve MR sensitivity and also reduce excitation power. In this work, we propose, for the first time, a quadrature array design strategy for parallel transmission at 298 MHz using single-feed circularly polarized (CP) patch antenna technique. Each array element is a nearly square ring microstrip antenna and is fed at a point on the diagonal of the antenna to generate quadrature magnetic fields. Compared with conventional quadrature coils, the single-feed structure is much simple and compact, making the quadrature coil array design practical. Numerical simulations demonstrate that the decoupling between elements is better than -35 dB for all the elements and the RF fields are homogeneous with deep penetration and quadrature behavior in the area of interest. Bloch equation simulation is also performed to simulate the excitation procedure by using an 8-element quadrature planar patch array to demonstrate its feasibility in parallel transmission at the ultrahigh field of 7 Tesla.

Keywords:  Patch antenna array; circularly polarized (CP); parallel transmission; quadrature

Year:  2014        PMID: 24649430      PMCID: PMC3947984          DOI: 10.3978/j.issn.2223-4292.2014.02.03

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  39 in total

1.  Microstrip RF surface coil design for extremely high-field MRI and spectroscopy.

Authors:  X Zhang; K Ugurbil; W Chen
Journal:  Magn Reson Med       Date:  2001-09       Impact factor: 4.668

2.  Current CONtrolled Transmit And Receive Coil Elements (CONTAR) for Parallel Acquisition and Parallel Excitation Techniques at High-Field MRI.

Authors:  E Kirilina; A Kühne; T Lindel; W Hoffmann; K H Rhein; T Riemer; F Seifert
Journal:  Appl Magn Reson       Date:  2011-08-21       Impact factor: 0.831

3.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

4.  Spatial domain method for the design of RF pulses in multicoil parallel excitation.

Authors:  William Grissom; Chun-yu Yip; Zhenghui Zhang; V Andrew Stenger; Jeffrey A Fessler; Douglas C Noll
Journal:  Magn Reson Med       Date:  2006-09       Impact factor: 4.668

5.  Array-optimized composite pulse for excellent whole-brain homogeneity in high-field MRI.

Authors:  Christopher M Collins; Zhangwei Wang; Weihua Mao; Jieming Fang; Wanzhan Liu; Michael B Smith
Journal:  Magn Reson Med       Date:  2007-03       Impact factor: 4.668

6.  Joint design of spoke trajectories and RF pulses for parallel excitation.

Authors:  Chao Ma; Dan Xu; Kevin F King; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2010-11-05       Impact factor: 4.668

7.  Integrated parallel reception, excitation, and shimming (iPRES).

Authors:  Hui Han; Allen W Song; Trong-Kha Truong
Journal:  Magn Reson Med       Date:  2013-04-29       Impact factor: 4.668

8.  Multi-channel microstrip transceiver arrays using harmonics for high field MR imaging in humans.

Authors:  Bing Wu; Chunsheng Wang; Jonathan Lu; Yong Pang; Sarah J Nelson; Daniel B Vigneron; Xiaoliang Zhang
Journal:  IEEE Trans Med Imaging       Date:  2011-08-30       Impact factor: 10.048

9.  Simultaneous multislice excitation by parallel transmission.

Authors:  Benedikt A Poser; Robert James Anderson; Bastien Guérin; Kawin Setsompop; Weiran Deng; Azma Mareyam; Peter Serano; Lawrence L Wald; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2013-05-28       Impact factor: 4.668

10.  High-flip-angle slice-selective parallel RF transmission with 8 channels at 7 T.

Authors:  Kawin Setsompop; Vijayanand Alagappan; Adam C Zelinski; Andreas Potthast; Ulrich Fontius; Franz Hebrank; Franz Schmitt; Lawrence L Wald; Elfar Adalsteinsson
Journal:  J Magn Reson       Date:  2008-08-30       Impact factor: 2.229

View more
  2 in total

1.  Parallel and sparse MR imaging: methods and instruments-Part 1.

Authors:  Xiaoliang Zhang; Jim X Ji
Journal:  Quant Imaging Med Surg       Date:  2014-02

Review 2.  Magnetic resonance imaging for lung cancer screen.

Authors:  Yi-Xiang J Wang; Gladys G Lo; Jing Yuan; Peder E Z Larson; Xiaoliang Zhang
Journal:  J Thorac Dis       Date:  2014-09       Impact factor: 2.895

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.