Accuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems.

Scott E Crouter1, Amanda Antczak, Jonathan R Hudak, Diane M DellaValle, Jere D Haas.   

Abstract

This study examined the accuracy and reliability of the MedGraphics VO2000 (VO2000) portable metabolic system and the ParvoMedics TrueOne 2400 (TrueOne 2400) metabolic cart against the criterion Douglas bag (DB) method. Ten healthy males (age 20 +/- 1.7 years) had their gas exchange variables measured at rest and during cycling at 50, 100, 150, 200, and 250 W. Each stage was 10-12 min. For half of the stage gas exchange was measured with the DB and TrueOne 2400 simultaneously and for the other half of the stage gas exchange was measured with the VO2000. The testing was performed on two separate days and the order in which the equipment was used in each stage was randomized. Reliability between days for V (E) (CV 7.3-8.8%) was similar among devices, however, for VO2, and VCO2 the VO2000 (CV 14.2-15.8%) was less reliable compared to the DB (CV 5.3-6.0%) and TrueOne 2400 (CV 4.7-5.7%). The TrueOne 2400 was not significantly different from the DB at rest or any work rate for V (E), VO2, or VCO2 (P > or = 0.05). The VO2000 was significantly different from the DB for V (E) at 50-100 W, VO2 at rest and 100-250 W, and VCO2 at rest and 200-250 W (all, P < 0.05). The TrueOne 2400 provides accurate and reliable results for the measurement of gas exchange variables. The VO2000 portable metabolic system was less reliable for measuring VO2 and VCO2 and generally overestimates VO2 at most cycling work rates. Further research is needed to confirm the results found with the VO2000.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16896734     DOI: 10.1007/s00421-006-0255-0

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  22 in total

1.  Validation of the COSMED K4 b2 portable metabolic system.

Authors:  J E McLaughlin; G A King; E T Howley; D R Bassett; B E Ainsworth
Journal:  Int J Sports Med       Date:  2001-05       Impact factor: 3.118

2.  Validation of the portable VmaxST system for oxygen-uptake measurement.

Authors:  M-A Brehm; J Harlaar; H Groepenhof
Journal:  Gait Posture       Date:  2004-08       Impact factor: 2.840

Review 3.  Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine.

Authors:  G Atkinson; A M Nevill
Journal:  Sports Med       Date:  1998-10       Impact factor: 11.136

4.  Validity and reliability of three commercially available breath-by-breath respiratory systems.

Authors:  James Carter; Asker E Jeukendrup
Journal:  Eur J Appl Physiol       Date:  2002-02-05       Impact factor: 3.078

5.  Validity of inspiratory and expiratory methods of measuring gas exchange with a computerized system.

Authors:  D R Bassett; E T Howley; D L Thompson; G A King; S J Strath; J E McLaughlin; B B Parr
Journal:  J Appl Physiol (1985)       Date:  2001-07

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  Evaluation of the Cosmed K2 telemetry system during exercise at moderate altitude.

Authors:  A X Bigard; C Y Guezennec
Journal:  Med Sci Sports Exerc       Date:  1995-09       Impact factor: 5.411

8.  Comparison of three field methods for measuring oxygen consumption.

Authors:  V Louhevaara; J Ilmarinen; P Oja
Journal:  Ergonomics       Date:  1985-02       Impact factor: 2.778

9.  Computerized determination of pneumotachometer characteristics using a calibrated syringe.

Authors:  M P Yeh; R M Gardner; T D Adams; F G Yanowitz
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1982-07

10.  CPX/D underestimates VO(2) in athletes compared with an automated Douglas bag system.

Authors:  Christopher J Gore; Robert J Clark; Nicholas J Shipp; Grant E Van Der Ploeg; Robert T Withers
Journal:  Med Sci Sports Exerc       Date:  2003-08       Impact factor: 5.411

View more
  56 in total

Review 1.  Measurement of human energy expenditure, with particular reference to field studies: an historical perspective.

Authors:  Roy J Shephard; Yukitoshi Aoyagi
Journal:  Eur J Appl Physiol       Date:  2011-12-11       Impact factor: 3.078

2.  Kinematical changes in swimming front Crawl and Breaststroke with the AquaTrainer snorkel.

Authors:  Tiago Barbosa; António José Silva; António Malvas Reis; Mário Costa; Nuno Garrido; Fernando Policarpo; Victor Machado Reis
Journal:  Eur J Appl Physiol       Date:  2010-04-09       Impact factor: 3.078

3.  Comparison of metabolic gas analysis between a standard laboratory system and a portable device.

Authors:  Leah C Stroud; Alan H Feiveson; Robert Ploutz-Snyder; John K De Witt; Meghan E Everett; Michael L Gernhardt
Journal:  J Sports Sci Med       Date:  2009-09-01       Impact factor: 2.988

4.  Exercise intensity affects acute neurotrophic and neurophysiological responses poststroke.

Authors:  Pierce Boyne; Colleen Meyrose; Jennifer Westover; Dustyn Whitesel; Kristal Hatter; Darcy S Reisman; David Cunningham; Daniel Carl; Connor Jansen; Jane C Khoury; Myron Gerson; Brett Kissela; Kari Dunning
Journal:  J Appl Physiol (1985)       Date:  2018-12-20

5.  Determining the Accuracy and Reliability of Indirect Calorimeters Utilizing the Methanol Combustion Technique.

Authors:  Sepideh Kaviani; Dale A Schoeller; Eric Ravussin; Edward L Melanson; Sarah T Henes; Lara R Dugas; Ronald E Dechert; George Mitri; Paul F M Schoffelen; Pim Gubbels; Asa Tornberg; Stephen Garland; Marco Akkermans; Jamie A Cooper
Journal:  Nutr Clin Pract       Date:  2018-04       Impact factor: 3.080

6.  Evaluation of the Oxycon Mobile metabolic system against the Douglas bag method.

Authors:  Hans Rosdahl; Lennart Gullstrand; Jane Salier-Eriksson; Patrik Johansson; Peter Schantz
Journal:  Eur J Appl Physiol       Date:  2009-12-31       Impact factor: 3.078

7.  Weight suppression and risk of future increases in body mass: effects of suppressed resting metabolic rate and energy expenditure.

Authors:  Eric Stice; Shelley Durant; Kyle S Burger; Dale A Schoeller
Journal:  Am J Clin Nutr       Date:  2011-04-27       Impact factor: 7.045

8.  Handheld Indirect Calorimetry as a Clinical Tool for Measuring Resting Energy Expenditure in Children with and without Obesity.

Authors:  David A White; Vincent S Staggs; Veronica Williams; Trent C Edwards; Robin Shook; Valentina Shakhnovich
Journal:  Child Obes       Date:  2019-03-19       Impact factor: 2.992

Review 9.  Open-circuit respirometry: real-time, laboratory-based systems.

Authors:  Susan A Ward
Journal:  Eur J Appl Physiol       Date:  2018-05-04       Impact factor: 3.078

10.  Relationship of BODE Index to functional tests in chronic obstructive pulmonary disease.

Authors:  Eloisa Maria Gatti Regueiro; Valéria Amorim Pires Di Lorenzo; Renata Pedrolongo Basso; Bruna Varanda Pessoa; Mauricio Jamami; Dirceu Costa
Journal:  Clinics (Sao Paulo)       Date:  2009       Impact factor: 2.365

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.