Literature DB >> 11882930

Validity and reliability of three commercially available breath-by-breath respiratory systems.

James Carter1, Asker E Jeukendrup.   

Abstract

Information concerning the validity and reliability of commercial on-line gas analysis systems is limited. The aim of this study was to provide a comparison of the validity and reliability of three on-line systems (Oxycon Alpha, Oxycon Pro and Pulmolab EX670) with that of Douglas bags. Two separate studies were conducted. In study 1, the three gas analysis systems were compared with Douglas bags using a metabolic simulator over four increases in ventilation. In study 2, ten subjects were split into equal groups exercising at 100 W or 150 W for 85 min on three separate occasions. Each system was used twice per visit. Study 1 demonstrated that the Oxycon Alpha and Douglas bags produced similar respiratory values over all levels of ventilation. The Oxycon Pro tended to slightly overestimate mean expiratory flow (V(E) ), oxygen uptake ( VO2), carbon dioxide production (VCO2) and respiratory exchange ratio (RER) at the higher ventilations. The Pulmolab produced large overestimations at all ventilations for and RER (up to 26.3% away from expectations), whilst values for, and were slightly underestimated at higher ventilations (up to 7.5% from expectations). The results of study 2 support the findings of study 1, with the Oxycon Pro and Oxycon Alpha producing similar results compared to Douglas bags for, and RER. The coefficients of variation for and measured using Douglas bags, Oxycon Pro and Oxycon Alpha were 3.3-5.1%, 4.7-7.0% and 4.5-6.3%, respectively, whilst that for the Pulmolab was highly variable (26.8-45.8%). The exercise study showed the Oxycon Pro and Oxycon Alpha to be both valid and reliable on-line systems for the measurement of parameters of respiration, at least at workloads up to 150 W.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11882930     DOI: 10.1007/s00421-001-0572-2

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  40 in total

1.  Test-retest errors and the apparent heterogeneity of training response.

Authors:  R J Shephard; T Rankinen; C Bouchard
Journal:  Eur J Appl Physiol       Date:  2003-10-17       Impact factor: 3.078

2.  Block training periodization in alpine skiing: effects of 11-day HIT on VO2max and performance.

Authors:  Fabio A Breil; Simone N Weber; Stefan Koller; Hans Hoppeler; Michael Vogt
Journal:  Eur J Appl Physiol       Date:  2010-04-04       Impact factor: 3.078

3.  Accuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems.

Authors:  Scott E Crouter; Amanda Antczak; Jonathan R Hudak; Diane M DellaValle; Jere D Haas
Journal:  Eur J Appl Physiol       Date:  2006-08-03       Impact factor: 3.078

4.  Assessment of energy demand in Laser sailing: influences of exercise duration and performance level.

Authors:  O Castagna; J Brisswalter
Journal:  Eur J Appl Physiol       Date:  2006-12-05       Impact factor: 3.078

5.  Determining the Accuracy and Reliability of Indirect Calorimeters Utilizing the Methanol Combustion Technique.

Authors:  Sepideh Kaviani; Dale A Schoeller; Eric Ravussin; Edward L Melanson; Sarah T Henes; Lara R Dugas; Ronald E Dechert; George Mitri; Paul F M Schoffelen; Pim Gubbels; Asa Tornberg; Stephen Garland; Marco Akkermans; Jamie A Cooper
Journal:  Nutr Clin Pract       Date:  2018-04       Impact factor: 3.080

6.  Evaluation of the Oxycon Mobile metabolic system against the Douglas bag method.

Authors:  Hans Rosdahl; Lennart Gullstrand; Jane Salier-Eriksson; Patrik Johansson; Peter Schantz
Journal:  Eur J Appl Physiol       Date:  2009-12-31       Impact factor: 3.078

7.  The Moxus Modular metabolic system evaluated with two sensors for ventilation against the Douglas bag method.

Authors:  Hans Rosdahl; Thomas Lindberg; Fredrik Edin; Johnny Nilsson
Journal:  Eur J Appl Physiol       Date:  2012-12-07       Impact factor: 3.078

8.  Effects of Cycling Versus Running Training on Sprint and Endurance Capacity in Inline Speed Skating.

Authors:  Carolin Stangier; Thomas Abel; Julia Mierau; Wildor Hollmann; Heiko K Strüder
Journal:  J Sports Sci Med       Date:  2016-02-23       Impact factor: 2.988

Review 9.  The effect of green tea extract on fat oxidation at rest and during exercise: evidence of efficacy and proposed mechanisms.

Authors:  Adrian B Hodgson; Rebecca K Randell; Asker E Jeukendrup
Journal:  Adv Nutr       Date:  2013-03-01       Impact factor: 8.701

Review 10.  Estimating human energy expenditure: a review of techniques with particular reference to doubly labelled water.

Authors:  Philip Ainslie; Thomas Reilly; Klass Westerterp
Journal:  Sports Med       Date:  2003       Impact factor: 11.136

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.