Literature DB >> 8531634

Evaluation of the Cosmed K2 telemetry system during exercise at moderate altitude.

A X Bigard1, C Y Guezennec.   

Abstract

The aim of this study was to test the linearity, precision, and accuracy of the measurements made by the K2 system at sea level (SL) and moderate altitude (MA) (barometric pressure = 591.5 +/- 0.5 mm Hg). To minimize the day-to-day biovariability, a testing protocol based on repeated-alternated measures was used at rest and during three levels of submaximal exercice lasting 12 min each, at 25%, 50%, 75% of the peak workload. The measurements of the respiratory parameters were compared with those obtained with a metabolic measurement cart. The results reported in this study show that the K2 system was an accurate and consistent system for oxygen uptake (VO2) measurements at SL. The K2 system was consistent at MA; however, the K2 system significantly overestimated and underestimated the VO2 computations at rest and 25% of the peak workload, respectively. The calculation of VO2 using the K2 system which assumes that RER = 1.00 had specific effects for the calculation of oxygen uptake. The measurements of FEO2 selectively differed from those obtained with the metabolic measurement cart at MA. Therefore, we concluded that the K2 system was an accurate system for VO2 measurements during submaximal exercices (50%-75% of the peak workload) under laboratory conditions at MA (up to 2,000 m).

Entities:  

Mesh:

Year:  1995        PMID: 8531634

Source DB:  PubMed          Journal:  Med Sci Sports Exerc        ISSN: 0195-9131            Impact factor:   5.411


  5 in total

1.  Accuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems.

Authors:  Scott E Crouter; Amanda Antczak; Jonathan R Hudak; Diane M DellaValle; Jere D Haas
Journal:  Eur J Appl Physiol       Date:  2006-08-03       Impact factor: 3.078

Review 2.  Automated metabolic gas analysis systems: a review.

Authors:  D J Macfarlane
Journal:  Sports Med       Date:  2001       Impact factor: 11.136

3.  Development of a sports specific aerobic capacity test for karate - a pilot study.

Authors:  David Nunan
Journal:  J Sports Sci Med       Date:  2006-07-01       Impact factor: 2.988

4.  Increase in energy cost of running at the end of a triathlon.

Authors:  C Y Guezennec; J M Vallier; A X Bigard; A Durey
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1996

5.  Assessing Cardiorespiratory Fitness of Soccer Players: Is Test Specificity the Issue?-A Review.

Authors:  Monèm Jemni; Mohammad Shoaib Prince; Julien S Baker
Journal:  Sports Med Open       Date:  2018-06-19
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.