Literature DB >> 11408433

Validity of inspiratory and expiratory methods of measuring gas exchange with a computerized system.

D R Bassett1, E T Howley, D L Thompson, G A King, S J Strath, J E McLaughlin, B B Parr.   

Abstract

The accuracy of a computerized metabolic system, using inspiratory and expiratory methods of measuring ventilation, was assessed in eight male subjects. Gas exchange was measured at rest and during five stages on a cycle ergometer. Pneumotachometers were placed on the inspired and expired side to measure inspired (VI) and expired ventilation (VE). The devices were connected to two systems sampling expired O(2) and CO(2) from a single mixing chamber. Simultaneously, the criterion (Douglas bag, or DB) method assessed VE and fractions of O(2) and CO(2) in expired gas (FE(O(2)) and FE(CO(2))) for subsequent calculation of O(2) uptake (VO(2)), CO(2) production (VCO(2)), and respiratory exchange ratio. Both systems accurately measured metabolic variables over a wide range of intensities. Though differences were found between the DB and computerized systems for FE(O(2)) (both inspired and expired systems), FE(CO(2)) (expired system only), and VO(2) (inspired system only), the differences were extremely small (FE(O(2)) = 0.0004, FE(CO(2)) = -0.0003, VO(2) = -0.018 l/min). Thus a computerized system, using inspiratory or expiratory configurations, permits extremely precise measurements to be made in a less time-consuming manner than the DB technique.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11408433     DOI: 10.1152/jappl.2001.91.1.218

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  48 in total

Review 1.  Measurement of human energy expenditure, with particular reference to field studies: an historical perspective.

Authors:  Roy J Shephard; Yukitoshi Aoyagi
Journal:  Eur J Appl Physiol       Date:  2011-12-11       Impact factor: 3.078

2.  Validation of an equation for predicting energy cost of arm ergometry in women.

Authors:  Swapan Mookerjee; Cynthia Surmacz; Margaret Till; Brandy Weller
Journal:  Eur J Appl Physiol       Date:  2005-07-20       Impact factor: 3.078

3.  Accuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems.

Authors:  Scott E Crouter; Amanda Antczak; Jonathan R Hudak; Diane M DellaValle; Jere D Haas
Journal:  Eur J Appl Physiol       Date:  2006-08-03       Impact factor: 3.078

Review 4.  Automated metabolic gas analysis systems: a review.

Authors:  D J Macfarlane
Journal:  Sports Med       Date:  2001       Impact factor: 11.136

5.  Maximal strength, power, and aerobic endurance adaptations to concurrent strength and sprint interval training.

Authors:  Gregory S Cantrell; Brian K Schilling; Max R Paquette; Zsolt Murlasits
Journal:  Eur J Appl Physiol       Date:  2014-01-05       Impact factor: 3.078

6.  Comparison of metabolic gas analysis between a standard laboratory system and a portable device.

Authors:  Leah C Stroud; Alan H Feiveson; Robert Ploutz-Snyder; John K De Witt; Meghan E Everett; Michael L Gernhardt
Journal:  J Sports Sci Med       Date:  2009-09-01       Impact factor: 2.988

7.  Determining the Accuracy and Reliability of Indirect Calorimeters Utilizing the Methanol Combustion Technique.

Authors:  Sepideh Kaviani; Dale A Schoeller; Eric Ravussin; Edward L Melanson; Sarah T Henes; Lara R Dugas; Ronald E Dechert; George Mitri; Paul F M Schoffelen; Pim Gubbels; Asa Tornberg; Stephen Garland; Marco Akkermans; Jamie A Cooper
Journal:  Nutr Clin Pract       Date:  2018-04       Impact factor: 3.080

8.  What are the functional outcomes of endoprosthestic reconstructions after tumor resection?

Authors:  Nicholas M Bernthal; Marcia Greenberg; Kent Heberer; Jeffrey J Eckardt; Eileen G Fowler
Journal:  Clin Orthop Relat Res       Date:  2015-03       Impact factor: 4.176

Review 9.  Open-circuit respirometry: real-time, laboratory-based systems.

Authors:  Susan A Ward
Journal:  Eur J Appl Physiol       Date:  2018-05-04       Impact factor: 3.078

10.  Accuracy of optimized branched algorithms to assess activity-specific physical activity energy expenditure.

Authors:  Andy G Edwards; James O Hill; William C Byrnes; Raymond C Browning
Journal:  Med Sci Sports Exerc       Date:  2010-04       Impact factor: 5.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.