Literature DB >> 11414671

Validation of the COSMED K4 b2 portable metabolic system.

J E McLaughlin1, G A King, E T Howley, D R Bassett, B E Ainsworth.   

Abstract

The purpose of this investigation was to assess the accuracy of the COSMED K4 b2 portable metabolic measurement system against the criterion Douglas bag (DB) method. During cycle ergometry on consecutive days, oxygen consumption (VO2), carbon dioxide production (VCO2), minute ventilation (VE), and respiratory exchange ratio (R) were measured at rest and during power outputs of 50, 100, 150, 200, and 250W. No significant differences (P > 0.05) were observed in VO2 between the K4 b2 and DB at rest and at 250W. Though the K4 b2 values were significantly higher (P<0.05) than DB values at 50, 100, 150, and 200 W, the magnitude of these differences was small (0.088, 0.092, 0.096, and 0.088 L x min(-1), respectively). VCO2 and VE values from the K4 b2 were significantly lower than the DB at 200 and 250 W, while no significant differences were observed from rest through 150W. The slight overestimation of VO2 (50-200 W) combined with the underestimation of VCO2 (200 and 250W) by the K4 b2 resulted in significantly lower R values at every stage. These findings suggest the COSMED K4 b2 portable metabolic measurement system is acceptable for measuring oxygen uptake over a fairly wide range of exercise intensities.

Entities:  

Mesh:

Year:  2001        PMID: 11414671     DOI: 10.1055/s-2001-13816

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  118 in total

1.  Validity of uniaxial accelerometry during activities of daily living in children.

Authors:  Joey C Eisenmann; Scott J Strath; Danny Shadrick; Paul Rigsby; Nicole Hirsch; Leigh Jacobson
Journal:  Eur J Appl Physiol       Date:  2003-10-21       Impact factor: 3.078

2.  Performance for short intermittent runs: active recovery vs. passive recovery.

Authors:  Grégory Dupont; Nicolas Blondel; Serge Berthoin
Journal:  Eur J Appl Physiol       Date:  2003-05-07       Impact factor: 3.078

3.  Effects of aerobic endurance training status and specificity on oxygen uptake kinetics during maximal exercise.

Authors:  Fabrizio Caputo; Benedito Sérgio Denadai
Journal:  Eur J Appl Physiol       Date:  2004-07-10       Impact factor: 3.078

4.  Defining accelerometer thresholds for activity intensities in adolescent girls.

Authors:  Margarita S Treuth; Kathryn Schmitz; Diane J Catellier; Robert G McMurray; David M Murray; M Joao Almeida; Scott Going; James E Norman; Russell Pate
Journal:  Med Sci Sports Exerc       Date:  2004-07       Impact factor: 5.411

5.  Effects of active recovery between series on performance during an intermittent exercise model in young endurance athletes.

Authors:  Magaly Tardieu-Berger; Delphine Thevenet; Hassane Zouhal; Jacques Prioux
Journal:  Eur J Appl Physiol       Date:  2004-07-27       Impact factor: 3.078

Review 6.  Measurement of human energy expenditure, with particular reference to field studies: an historical perspective.

Authors:  Roy J Shephard; Yukitoshi Aoyagi
Journal:  Eur J Appl Physiol       Date:  2011-12-11       Impact factor: 3.078

7.  Performance and physiological responses to repeated-sprint and jump sequences.

Authors:  Martin Buchheit
Journal:  Eur J Appl Physiol       Date:  2010-07-30       Impact factor: 3.078

8.  Kinematical changes in swimming front Crawl and Breaststroke with the AquaTrainer snorkel.

Authors:  Tiago Barbosa; António José Silva; António Malvas Reis; Mário Costa; Nuno Garrido; Fernando Policarpo; Victor Machado Reis
Journal:  Eur J Appl Physiol       Date:  2010-04-09       Impact factor: 3.078

9.  Kick frequency affects the energy cost of aquatic locomotion in elite monofin swimmers.

Authors:  Guillaume Boitel; Fabrice Vercruyssen; Morgan Alberty; Xavier Nesi; Lionel Bourdon; Jeanick Brisswalter
Journal:  Eur J Appl Physiol       Date:  2010-04-06       Impact factor: 3.078

10.  Physical activity energy expenditure measured using a portable telemetric device in comparison with a mass spectrometer.

Authors:  C Maiolo; G Melchiorri; L Iacopino; S Masala; A De Lorenzo
Journal:  Br J Sports Med       Date:  2003       Impact factor: 13.800

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.