Validation of the portable VmaxST system for oxygen-uptake measurement.

M-A Brehm1, J Harlaar, H Groepenhof.   

Abstract

The aim of this study was to validate the accuracy of a new type of portable gas-analysis system (Sensormedics VmaxST) for the measurement of oxygen-uptake at expenditure levels that are reached during walking in patients with movement disorders. The criterion method was the Douglas Bag (DB) method, which is considered to be the gold standard. Accuracy evaluations were made in two trials, randomly using the VmaxST (ST) and the Douglas Bag method. Ten healthy adult subjects participated in the trials (age: 28.8 (4.3) years; body mass: 75 (13.3)kg; height: 179.3 (8.9)cm). Each trial consisted of two time periods: 5 min of resting in a comfortable chair and 5 min of cycling at an 80 W workload. During the fifth minute of each block, mean minute ventilation (VE), oxygen-uptake (VO2), and carbon dioxide production (VCO2) were measured or calculated for both systems. Energy expenditure (EE) values were calculated and net values calculated by subtracting resting measurements from gross measurements. The results show that no significant differences were found between the VmaxST and the Douglas Bag method for the primary parameters: EEnet and VO2net. Significantly higher values were found for rest and exercise values. However, these differences were very small. Therefore, the validity of the VmaxST is sufficient for use in gait studies to determine the energy cost of walking, especially when net values are calculated. Copyright 2003 Elsevier B.V.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15196523     DOI: 10.1016/S0966-6362(03)00097-3

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  17 in total

1.  Validity, reliability and stability of the portable Cortex Metamax 3B gas analysis system.

Authors:  D J Macfarlane; P Wong
Journal:  Eur J Appl Physiol       Date:  2011-11-11       Impact factor: 3.078

Review 2.  Measurement of human energy expenditure, with particular reference to field studies: an historical perspective.

Authors:  Roy J Shephard; Yukitoshi Aoyagi
Journal:  Eur J Appl Physiol       Date:  2011-12-11       Impact factor: 3.078

3.  Muscle activation and energy-requirements for varying postures in children and adolescents with cerebral palsy.

Authors:  Olaf Verschuren; Mark D Peterson; Svenja Leferink; Johanna Darrah
Journal:  J Pediatr       Date:  2014-08-20       Impact factor: 4.406

4.  Accuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems.

Authors:  Scott E Crouter; Amanda Antczak; Jonathan R Hudak; Diane M DellaValle; Jere D Haas
Journal:  Eur J Appl Physiol       Date:  2006-08-03       Impact factor: 3.078

5.  The stress of chess players as a model to study the effects of psychological stimuli on physiological responses: an example of substrate oxidation and heart rate variability in man.

Authors:  Nicolas Troubat; Marie-Agnes Fargeas-Gluck; Mikko Tulppo; Benoit Dugué
Journal:  Eur J Appl Physiol       Date:  2008-11-06       Impact factor: 3.078

6.  Evaluation of the Oxycon Mobile metabolic system against the Douglas bag method.

Authors:  Hans Rosdahl; Lennart Gullstrand; Jane Salier-Eriksson; Patrik Johansson; Peter Schantz
Journal:  Eur J Appl Physiol       Date:  2009-12-31       Impact factor: 3.078

7.  Reliability and responsiveness of cardiopulmonary exercise testing in fatigued persons with multiple sclerosis and low to mild disability.

Authors:  Martin Heine; Lizanne Eva van den Akker; Olaf Verschuren; Anne Visser-Meily; Gert Kwakkel
Journal:  PLoS One       Date:  2015-03-19       Impact factor: 3.240

Review 8.  Open-circuit respirometry: a historical review of portable gas analysis systems.

Authors:  Duncan J Macfarlane
Journal:  Eur J Appl Physiol       Date:  2017-10-17       Impact factor: 3.078

9.  Limiting factors in peak oxygen uptake and the relationship with functional ambulation in ambulating children with spina bifida.

Authors:  J F De Groot; T Takken; M A G C Schoenmakers; L Vanhees; P J M Helders
Journal:  Eur J Appl Physiol       Date:  2008-07-10       Impact factor: 3.078

10.  Test-retest reliability and minimum detectable change using the K4b2: oxygen consumption, gait efficiency, and heart rate for healthy adults during submaximal walking.

Authors:  Benjamin J Darter; Kelly M Rodriguez; Jason M Wilken
Journal:  Res Q Exerc Sport       Date:  2013-06       Impact factor: 2.500

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.