Literature DB >> 16832671

[Dynamic contour tonometry].

C Kniestedt1, H E Kanngiesser.   

Abstract

Dynamic contour tonometry (DCT) is a new technology for noninvasive and direct measurement of intraocular pressure (IOP); its results are thought to be influenced less than those of other methods by structural characteristics of the eye. The curvature of the pressure sensing device is concave and only slightly flatter than that of the human cornea. The cornea adapts to the curvature of the transducer head, and the sensor in the centre of the adapted area measures the pressure on the other side of the cornea in the force-free range. Studies published so far suggest that DCT is less heavily dependent than applanation tonometry on the biomechanical properties of the cornea . A further advantage of DCT over other forms of tonometry is the capability of dynamic measurements over time. It is also possible to measure both the diastolic and the systolic IOD and determine the difference between the two, i.e. the ocular pulse amplitude (OPA). OPA is an indirect indicator of choroidal perfusion and reflects the condition of the arterial vascular system and the action of the heart. It could be important in the diagnosis and treatment of glaucoma.

Entities:  

Mesh:

Year:  2006        PMID: 16832671     DOI: 10.1007/s00347-006-1387-7

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  28 in total

1.  Correlation between intraocular pressure, central corneal thickness, stage of glaucoma, and demographic patient data: prospective analysis of biophysical parameters in tertiary glaucoma practice populations.

Authors:  Christoph Kniestedt; Shan Lin; Joyce Choe; Michelle Nee; Alan Bostrom; Jörg Stürmer; Robert L Stamper
Journal:  J Glaucoma       Date:  2006-04       Impact factor: 2.503

2.  [Applanation tonometry].

Authors:  H GOLDMANN; T SCHMIDT
Journal:  Ophthalmologica       Date:  1957-10       Impact factor: 3.250

3.  Clinical tonography; the scleral rigidity correction.

Authors:  R A MOSES; B BECKER
Journal:  Am J Ophthalmol       Date:  1958-02       Impact factor: 5.258

4.  Determining in vivo biomechanical properties of the cornea with an ocular response analyzer.

Authors:  David A Luce
Journal:  J Cataract Refract Surg       Date:  2005-01       Impact factor: 3.351

5.  Ocular pulse amplitude after trabeculectomy.

Authors:  Sandra R von Schulthess; Claude Kaufmann; Lucas M Bachmann; Ahmet Yanar; Michael A Thiel
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-07-23       Impact factor: 3.117

6.  The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry.

Authors:  A Kotecha; E T White; J M Shewry; D F Garway-Heath
Journal:  Br J Ophthalmol       Date:  2005-12       Impact factor: 4.638

Review 7.  Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach.

Authors:  M J Doughty; M L Zaman
Journal:  Surv Ophthalmol       Date:  2000 Mar-Apr       Impact factor: 6.048

8.  The ocular pulse.

Authors:  E S Perkins
Journal:  Curr Eye Res       Date:  1981       Impact factor: 2.424

9.  Accuracy of dynamic contour tonometry compared with applanation tonometry in human cadaver eyes of different hydration states.

Authors:  Christoph Kniestedt; Michelle Nee; Robert L Stamper
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2004-10-13       Impact factor: 3.117

10.  Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis.

Authors:  Claude Kaufmann; Lucas M Bachmann; Michael A Thiel
Journal:  Invest Ophthalmol Vis Sci       Date:  2003-09       Impact factor: 4.799

View more
  11 in total

1.  [Influence of residual corneal bed thickness after myopic LASIK on intraocular pressure measurements. Goldmann applanation tonometry and dynamic contour tonometry].

Authors:  L Muller; T Kohnen
Journal:  Ophthalmologe       Date:  2009-01       Impact factor: 1.059

2.  [Mobile intraocular pressure measurement. From palpation to initial clinical experience with the handheld dynamic contour tonometer].

Authors:  U Schmid; C Kniestedt
Journal:  Ophthalmologe       Date:  2010-07       Impact factor: 1.059

3.  [A comparison of rebound tonometry (ICare) with TonoPenXL and Goldmann applanation tonometry].

Authors:  W Schreiber; C K Vorwerk; A Langenbucher; W Behrens-Baumann; A Viestenz
Journal:  Ophthalmologe       Date:  2007-04       Impact factor: 1.059

4.  [Continuous intraocular pressure measurement: First results with a pressure-sensitive contact lens].

Authors:  A Hediger; C Kniestedt; S Zweifel; P Knecht; J Funk; H Kanngiesser
Journal:  Ophthalmologe       Date:  2009-12       Impact factor: 1.059

5.  [Methods of measuring intraocular pressure independently of central corneal thickness].

Authors:  A Hager; W Wiegand
Journal:  Ophthalmologe       Date:  2008-09       Impact factor: 1.059

6.  The Effects of Trabeculectomy on Ocular Pulse Amplitude in Patients with Glaucoma.

Authors:  Yalcin Karakucuk
Journal:  Beyoglu Eye J       Date:  2019-12-24

7.  Clinical utility of spectral analysis of intraocular pressure pulse wave.

Authors:  Magdalena Asejczyk-Widlicka; Patrycja Krzyżanowska-Berkowska; Małgorzata Kowalska; D Robert Iskander
Journal:  BMC Ophthalmol       Date:  2014-03-12       Impact factor: 2.209

8.  Can dynamic contour tonometry and ocular pulse amplitude help to detect severe cardiovascular pathologies?

Authors:  T Bertelmann; S Langanke; M Potstawa; I Strempel
Journal:  Clin Ophthalmol       Date:  2014-07-14

9.  Cyclic RNA hsa‑circ‑000595 regulates apoptosis of aortic smooth muscle cells.

Authors:  Chengfei Zheng; Hui Niu; Ming Li; Hongkun Zhang; Zhenggang Yang; Lu Tian; Ziheng Wu; Donglin Li; Xudong Chen
Journal:  Mol Med Rep       Date:  2015-08-28       Impact factor: 2.952

10.  [Intraocular pressure elevation after vitrectomy-Goldmann applanation tonometry measures lower intraocular pressure than dynamic contour tonometry].

Authors:  Sebastian Bäurle; Anja Viestenz; Berthold Seitz; Arne Viestenz
Journal:  Ophthalmologe       Date:  2021-07-06       Impact factor: 1.059

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.