Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis.

Claude Kaufmann1, Lucas M Bachmann, Michael A Thiel.   

Abstract

PURPOSE: Thinning of the corneal stroma by laser in situ keratomileusis (LASIK) results in inaccurate low intraocular pressure (IOP) readings by Goldmann applanation tonometry (GAT). Dynamic contour tonometry (DCT) is a novel measuring technique, designed to measure IOP largely independent of corneal thickness and curvature. The purpose of this study was to compare IOP measurements using GAT and DCT in eyes undergoing LASIK for correction of myopia.
METHODS: In a prospective, single-center study, central corneal thickness (CCT) and IOP were measured in patients undergoing first-time LASIK for myopia. IOP was measured before and after surgery using GAT and DCT. The untreated contralateral eyes served as paired controls.
RESULTS: There was good concordance between the two tonometers in 62 normal eyes before LASIK. Corneal ablation of 90.0 +/- 49.18 micro m (median +/- SD) reduced IOP readings as measured by GAT by 3.0 +/- 1.9 mm Hg (P < 0.001). In contrast, no significant change in IOP readings was recorded by DCT (-0.2 mm Hg +/- 1.5 mm Hg, P = 0.30). There was no change in IOP in the untreated control eyes as measured by GAT and DCT.
CONCLUSIONS: Significant decreases in IOP were recorded by GAT after LASIK for myopia. Measurements by DCT, however, did not reveal any significant changes in IOP.

Entities:  

Mesh:

Year:  2003        PMID: 12939293     DOI: 10.1167/iovs.02-0946

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  42 in total

1.  [Influence of corneal thickness on intraocular pressure measurements following Descemet's stripping automated endothelial keratoplasty (DSAEK)].

Authors:  M K J Klamann; A-K B Maier; J Gonnermann; N Torun; P C Ruokonen
Journal:  Ophthalmologe       Date:  2012-11       Impact factor: 1.059

2.  Intraocular pressure and ocular pulse amplitude variations during the Valsalva maneuver.

Authors:  Umit Aykan; Mesut Erdurmus; Burhan Yilmaz; Ahmet Hamdi Bilge
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-03-24       Impact factor: 3.117

3.  Evaluation of ocular pulse amplitude and choroidal thickness in diabetic macular edema.

Authors:  Y Totan; T K Akyüz; E Güler; F B Güragaç
Journal:  Eye (Lond)       Date:  2015-11-13       Impact factor: 3.775

Review 4.  [Glaucoma diagnostics and corneal thickness].

Authors:  J von Eicken; M Kohlhaas; H Höh
Journal:  Ophthalmologe       Date:  2005-09       Impact factor: 1.059

5.  The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry.

Authors:  P-A Tonnu; T Ho; T Newson; A El Sheikh; K Sharma; E White; C Bunce; D Garway-Heath
Journal:  Br J Ophthalmol       Date:  2005-07       Impact factor: 4.638

Review 6.  [The risk of glaucoma and corneal thickness].

Authors:  A G Böhm
Journal:  Ophthalmologe       Date:  2005-09       Impact factor: 1.059

Review 7.  [Dynamic contour tonometry].

Authors:  C Kniestedt; H E Kanngiesser
Journal:  Ophthalmologe       Date:  2006-08       Impact factor: 1.059

8.  Dynamic contour tonometry (DCT) versus Goldmann applanation tonometry (GAT) - a comparison of agreement and reproducibility.

Authors:  Sonja Herdener; Mona Pache; Sonja Lautebach; Jens Funk
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-12-20       Impact factor: 3.117

Review 9.  Biomechanics and wound healing in the cornea.

Authors:  William J Dupps; Steven E Wilson
Journal:  Exp Eye Res       Date:  2006-05-23       Impact factor: 3.467

10.  Dynamic contour tonometry versus Goldmann applanation tonometry: a comparative study.

Authors:  Mona Pache; Sonja Wilmsmeyer; Sonja Lautebach; Jens Funk
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-03-09       Impact factor: 3.117

View more