BACKGROUND: A prototype of a pressure-sensitive contact lens (CL-DCT) based on dynamic contour tonometry (DCT) has been developed for continuous intraocular pressure (IOP) monitoring. The purpose of the present study was to assess the clinical applicability of this CL-DCT. MATERIAL AND METHODS: In 24 healthy subjects continuous IOP recording with the CL-DCT for 100 s was accomplished including IOP monitoring during 2 consecutive Valsalva manoeuvres. The measurement procedure was repeated after 5 min on the same eye and compared with the initial measurement. RESULTS: Continuous pressure curves were recorded in 20 subjects. The CL-DCT revealed an individual increase in IOP from 0.74 to 8.26 mmHg during the Valsalva manoeuvres. Comparison of the 2 consecutive IOP measurements yielded a mean deviation of +/-0.4 mmHg. CONCLUSIONS: CL-DCT allows non-invasive and continuous measurements of IOP. The measured values are comparable to the expected ones. Further studies are necessary to compare the measurement accuracy of CL-DCT with that of slit lamp adapted DCT (SL-DCT).
BACKGROUND: A prototype of a pressure-sensitive contact lens (CL-DCT) based on dynamic contour tonometry (DCT) has been developed for continuous intraocular pressure (IOP) monitoring. The purpose of the present study was to assess the clinical applicability of this CL-DCT. MATERIAL AND METHODS: In 24 healthy subjects continuous IOP recording with the CL-DCT for 100 s was accomplished including IOP monitoring during 2 consecutive Valsalva manoeuvres. The measurement procedure was repeated after 5 min on the same eye and compared with the initial measurement. RESULTS: Continuous pressure curves were recorded in 20 subjects. The CL-DCT revealed an individual increase in IOP from 0.74 to 8.26 mmHg during the Valsalva manoeuvres. Comparison of the 2 consecutive IOP measurements yielded a mean deviation of +/-0.4 mmHg. CONCLUSIONS:CL-DCT allows non-invasive and continuous measurements of IOP. The measured values are comparable to the expected ones. Further studies are necessary to compare the measurement accuracy of CL-DCT with that of slit lamp adapted DCT (SL-DCT).
Authors: P Walter; U Schnakenberg; G vom Bögel; P Ruokonen; C Krüger; S Dinslage; H C Lüdtke Handjery; H Richter; W Mokwa; M Diestelhorst; G K Krieglstein Journal: Ophthalmic Res Date: 2000 Nov-Dec Impact factor: 2.892
Authors: Michael A Kass; Dale K Heuer; Eve J Higginbotham; Chris A Johnson; John L Keltner; J Philip Miller; Richard K Parrish; M Roy Wilson; Mae O Gordon Journal: Arch Ophthalmol Date: 2002-06
Authors: André Rosentreter; Kerstin S Jablonski; Anne C Mellein; Stergiani Gaki; Arno Hueber; Thomas S Dietlein Journal: Graefes Arch Clin Exp Ophthalmol Date: 2011-08-14 Impact factor: 3.117