Literature DB >> 19756646

[Continuous intraocular pressure measurement: First results with a pressure-sensitive contact lens].

A Hediger1, C Kniestedt, S Zweifel, P Knecht, J Funk, H Kanngiesser.   

Abstract

BACKGROUND: A prototype of a pressure-sensitive contact lens (CL-DCT) based on dynamic contour tonometry (DCT) has been developed for continuous intraocular pressure (IOP) monitoring. The purpose of the present study was to assess the clinical applicability of this CL-DCT.
MATERIAL AND METHODS: In 24 healthy subjects continuous IOP recording with the CL-DCT for 100 s was accomplished including IOP monitoring during 2 consecutive Valsalva manoeuvres. The measurement procedure was repeated after 5 min on the same eye and compared with the initial measurement.
RESULTS: Continuous pressure curves were recorded in 20 subjects. The CL-DCT revealed an individual increase in IOP from 0.74 to 8.26 mmHg during the Valsalva manoeuvres. Comparison of the 2 consecutive IOP measurements yielded a mean deviation of +/-0.4 mmHg.
CONCLUSIONS: CL-DCT allows non-invasive and continuous measurements of IOP. The measured values are comparable to the expected ones. Further studies are necessary to compare the measurement accuracy of CL-DCT with that of slit lamp adapted DCT (SL-DCT).

Entities:  

Mesh:

Year:  2009        PMID: 19756646     DOI: 10.1007/s00347-009-1919-z

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  13 in total

1.  Development of a completely encapsulated intraocular pressure sensor.

Authors:  P Walter; U Schnakenberg; G vom Bögel; P Ruokonen; C Krüger; S Dinslage; H C Lüdtke Handjery; H Richter; W Mokwa; M Diestelhorst; G K Krieglstein
Journal:  Ophthalmic Res       Date:  2000 Nov-Dec       Impact factor: 2.892

2.  Dynamic contour tonometry: presentation of a new tonometer.

Authors:  Hartmut E Kanngiesser; Christoph Kniestedt; Yves C A Robert
Journal:  J Glaucoma       Date:  2005-10       Impact factor: 2.503

Review 3.  [Dynamic contour tonometry].

Authors:  C Kniestedt; H E Kanngiesser
Journal:  Ophthalmologe       Date:  2006-08       Impact factor: 1.059

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Large diurnal fluctuations in intraocular pressure are an independent risk factor in patients with glaucoma.

Authors:  S Asrani; R Zeimer; J Wilensky; D Gieser; S Vitale; K Lindenmuth
Journal:  J Glaucoma       Date:  2000-04       Impact factor: 2.503

6.  The Ocular Hypertension Treatment Study: a randomized trial determines that topical ocular hypotensive medication delays or prevents the onset of primary open-angle glaucoma.

Authors:  Michael A Kass; Dale K Heuer; Eve J Higginbotham; Chris A Johnson; John L Keltner; J Philip Miller; Richard K Parrish; M Roy Wilson; Mae O Gordon
Journal:  Arch Ophthalmol       Date:  2002-06

7.  Retrobulbar blood flow in glaucoma patients with nocturnal over-dipping in systemic blood pressure.

Authors:  D Gherghel; S Orgül; K Gugleta; J Flammer
Journal:  Am J Ophthalmol       Date:  2001-11       Impact factor: 5.258

8.  Fluctuation of intraocular pressure and glaucoma progression in the early manifest glaucoma trial.

Authors:  Boel Bengtsson; M Cristina Leske; Leslie Hyman; Anders Heijl
Journal:  Ophthalmology       Date:  2006-11-13       Impact factor: 12.079

9.  First steps toward noninvasive intraocular pressure monitoring with a sensing contact lens.

Authors:  Matteo Leonardi; Peter Leuenberger; Daniel Bertrand; Arnaud Bertsch; Philippe Renaud
Journal:  Invest Ophthalmol Vis Sci       Date:  2004-09       Impact factor: 4.799

10.  Clinical comparison of pascal dynamic contour tonometry and goldmann applanation tonometry in asymmetric open-angle glaucoma.

Authors:  Michael Sullivan-Mee; Kathy D Halverson; Clifford Qualls
Journal:  J Glaucoma       Date:  2007-12       Impact factor: 2.503

View more
  4 in total

1.  [Continuous 24 h monitoring of changes in intraocular pressure with the wireless contact lens sensor Triggerfish™. First results in patients].

Authors:  C Faschinger; G Mossböck
Journal:  Ophthalmologe       Date:  2010-10       Impact factor: 1.059

2.  [Influence of mode of delivery on pre-existing eye diseases].

Authors:  A G M Jünemann; N Sterk; R Rejdak
Journal:  Ophthalmologe       Date:  2012-03       Impact factor: 1.059

3.  A new rebound tonometer for home monitoring of intraocular pressure.

Authors:  André Rosentreter; Kerstin S Jablonski; Anne C Mellein; Stergiani Gaki; Arno Hueber; Thomas S Dietlein
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-08-14       Impact factor: 3.117

4.  [Ease of handling of first and second generation rebound tonometers].

Authors:  N Mihailovic; J Termühlen; M Alnawaiseh; N Eter; T S Dietlein; A Rosentreter
Journal:  Ophthalmologe       Date:  2016-04       Impact factor: 1.059

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.