An alternate line erasure and readout (ALER) method for implementing slot-scan imaging technique with a flat-panel detector--initial experiences.

Xinming Liu1, Chris C Shaw, Mustafa C Altunbas, Tianpeng Wang.   

Abstract

This paper describes and demonstrates an electronic collimation method, referred to as the alternate line erasure and readout (ALER) technique, for implementing slot-scan digital radiography technique with an amorphous silicon (a-Si) thin-film transistor (TFT) array based flat-panel detector. An amorphus selenium (a-Se) flat-panel detector was modified to implement the ALER technique for slot-scan imaging. A stepping-motor driven fore-collimator was mounted in front of an X-ray tube to generate a scanning X-ray fan beam. The scanning speed and magnification were adjusted to synchronize the fan beam motion with the image line readout rate. The image lines on the leading and trailing edges of the fan beam were tracked and alternately reset and read out, respectively. The former operation resulted in the erasure of the scatter signals accumulated in the leading edge image line prior to the arrival of the fan beam. The latter operation resulted in the acquisition of fan beam exposure data integrated in the trailing edge image line right after the fan beam passed. To demonstrate the scatter rejection capability of this technique, an anthropomorphic chest phantom was placed in PA position and scanned at a speed of 576 lines (8.0 cm)/s at 117 kVp and 32 mA. A tungsten bar is placed at the entrance side of the chest phantom to measure the scatter-to-primary ratio (SPR), scatter reduction factor (SRF), and contrast-to-noise ratio degradation factor (CNRDF) in the slot-scan images to evaluate the effectiveness of scatter rejection and the resultant improvement of image quality. SPR and CNRDF in the open-field images were also measured and used as the reference for comparison. A scatter reduction by 86.4 to 95.4% across lower lung and heart regions has been observed with slot-scan imaging. The CNRs have been found to be improved by a factor of 2 in the mediastinum areas over the open-field image as well.

Entities:  

Mesh:

Year:  2006        PMID: 16608064      PMCID: PMC2000378          DOI: 10.1109/TMI.2006.870896

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  24 in total

1.  Radiographic contrast improvement by means of slit radiography.

Authors:  C Jaffe; E W Webster
Journal:  Radiology       Date:  1975-09       Impact factor: 11.105

2.  Fundamental imaging characteristics of a slot-scan digital chest radiographic system.

Authors:  Ehsan Samei; Robert S Saunders; Joseph Y Lo; James T Dobbins; Jonathan L Jesneck; Carey E Floyd; Carl E Ravin
Journal:  Med Phys       Date:  2004-09       Impact factor: 4.071

3.  Investigations of moving-slit radiography.

Authors:  J A Sorenson; J A Nelson
Journal:  Radiology       Date:  1976-09       Impact factor: 11.105

4.  A scanning system for chest radiography with regional exposure control: practical implementation.

Authors:  D B Plewes; E Vogelstein
Journal:  Med Phys       Date:  1983 Sep-Oct       Impact factor: 4.071

5.  Scanning multiple slit assembly: a practical and efficient device to reduce scatter.

Authors:  G T Barnes; I A Brezovich; D M Witten
Journal:  AJR Am J Roentgenol       Date:  1977-09       Impact factor: 3.959

6.  Diode array digital radiography: initial clinical experience.

Authors:  D Sashin; E J Sternglass; B S Slasky; K M Bron; J M Herron; W H Kennedy; L Shabason; J Boyer; A E Pollitt; R E Latchaw; B R Girdany; R W Simpson
Journal:  AJR Am J Roentgenol       Date:  1982-12       Impact factor: 3.959

7.  Rotating disk device for slit radiography of the chest.

Authors:  J A Sorenson; J A Nelson; L T Niklason; S C Jacobsen
Journal:  Radiology       Date:  1980-01       Impact factor: 11.105

8.  Scattered radiation in chest radiography.

Authors:  L T Niklason; J A Sorenson; J A Nelson
Journal:  Med Phys       Date:  1981 Sep-Oct       Impact factor: 4.071

9.  Improved contrast in special procedures using a rotating aperture wheel (RAW) device.

Authors:  S Rudin; D R Bednarek
Journal:  Radiology       Date:  1980-11       Impact factor: 11.105

10.  Digital slot-scan charge-coupled device radiography versus AMBER and Bucky screen-film radiography for detection of simulated nodules and interstitial disease in a chest phantom.

Authors:  Lucia J M Kroft; Jacob Geleijns; Bart J A Mertens; Wouter J H Veldkamp; Harmine M Zonderland; Albert de Roos
Journal:  Radiology       Date:  2004-04       Impact factor: 11.105

View more
  7 in total

1.  Effects of exposure equalization on image signal-to-noise ratios in digital mammography: a simulation study with an anthropomorphic breast phantom.

Authors:  Xinming Liu; Chao-Jen Lai; Gary J Whitman; William R Geiser; Youtao Shen; Ying Yi; Chris C Shaw
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images.

Authors:  Xinming Liu; Chris C Shaw
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

3.  Comparison of slot scanning digital mammography system with full-field digital mammography system.

Authors:  Chao-Jen Lai; Chris C Shaw; William Geiser; Lingyun Chen; Elsa Arribas; Tanya Stephens; Paul L Davis; Geetha P Ayyar; Basak E Dogan; Victoria A Nguyen; Gary J Whitman; Wei T Yang
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

4.  Scatter rejection and low-contrast performance of a slot-scan digital chest radiography system with electronic aft-collimation: a chest phantom study.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Mustafa C Altunbas; Lingyun Chen; Tao Han; Tianpeng Wang
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

5.  Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Tianpeng Wang
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

6.  Scan equalization digital radiography (SEDR) implemented with an amorphous selenium flat-panel detector: initial experience.

Authors:  Xinming Liu; Chao-Jen Lai; Lingyun Chen; Tao Han; Yuncheng Zhong; Youtao Shen; Tianpeng Wang; Chris C Shaw
Journal:  Phys Med Biol       Date:  2009-11-04       Impact factor: 3.609

7.  A unified scatter rejection and correction method for cone beam computed tomography.

Authors:  Cem Altunbas; Yeonok Park; Zhelin Yu; Anant Gopal
Journal:  Med Phys       Date:  2021-02-06       Impact factor: 4.071

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.