Literature DB >> 7433683

Improved contrast in special procedures using a rotating aperture wheel (RAW) device.

S Rudin, D R Bednarek.   

Abstract

A new scatter control technology consisting of multiple rotating aperture wheels (RAWs) is being developed to provide improved radiographic contrast and/or reduced patient dose in both single frame and dynamic procedures. The unique geometry of this system allows the conventional source-patient-image receptor geometric relationship to remain unchanged so that the device can be added to existing radiographic, fluoroscopic, and conventional tomographic installations. A prototype RAW device has been used with a rapid film changer for simulated abdominal angiography. The resulting images show improved contrast over those obtained with a standard 12:1 fixed grid.

Entities:  

Mesh:

Year:  1980        PMID: 7433683     DOI: 10.1148/radiology.137.2.7433683

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images.

Authors:  Xinming Liu; Chris C Shaw
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

2.  Scatter rejection and low-contrast performance of a slot-scan digital chest radiography system with electronic aft-collimation: a chest phantom study.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Mustafa C Altunbas; Lingyun Chen; Tao Han; Tianpeng Wang
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

3.  Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Tianpeng Wang
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

4.  Efficiency of the Human Observer Compared to an Ideal Observer Based on a Generalized NEQ Which Incorporates Scatter and Geometric Unsharpness: Evaluation with a 2AFC Experiment.

Authors:  Iacovos S Kyprianou; Arundhuti Ganguly; Stephen Rudin; Daniel R Bednarek; Brandon D Gallas; Kyle J Myers
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2005

5.  An alternate line erasure and readout (ALER) method for implementing slot-scan imaging technique with a flat-panel detector--initial experiences.

Authors:  Xinming Liu; Chris C Shaw; Mustafa C Altunbas; Tianpeng Wang
Journal:  IEEE Trans Med Imaging       Date:  2006-04       Impact factor: 10.048

6.  Scan equalization digital radiography (SEDR) implemented with an amorphous selenium flat-panel detector: initial experience.

Authors:  Xinming Liu; Chao-Jen Lai; Lingyun Chen; Tao Han; Yuncheng Zhong; Youtao Shen; Tianpeng Wang; Chris C Shaw
Journal:  Phys Med Biol       Date:  2009-11-04       Impact factor: 3.609

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.