A scanning system for chest radiography with regional exposure control: practical implementation.

D B Plewes, E Vogelstein.   

Abstract

An experimental scanning apparatus for chest radiography is described which offers good scatter rejection and regional manipulation of film exposure. The apparatus is capable of studying two scanning geometries that uses either a fan of radiation swept laterally over the film in 5s or a spot of radiation scanned over two dimensions in a raster pattern in 8.8s. The manipulation of tube output during the scan is achieved by pulse width modulation with film exposure monitored by a fluorescence detector placed behind the film cassette. Measurement of the scatter rejection properties of the system show that it is superior to that of a 10:1 grid when used with 120-kVp radiation. Phantom images with both geometries demonstrate the capability of the system to improve uniformity of film exposure and soft tissue contrast throughout the mediastinal, diaphragmatic, and retrocardiac areas. The relative characteristics of the one- versus two-dimension scan geometries are given. Clinical raster images formed with the 8.8-s scan time show signs of motion unsharpness which becomes insignificant when the scan time is reduced to 4.5 s.

Mesh:

Year:  1983        PMID: 6646071     DOI: 10.1118/1.595333

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images.

Authors:  Xinming Liu; Chris C Shaw
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

2.  Scatter rejection and low-contrast performance of a slot-scan digital chest radiography system with electronic aft-collimation: a chest phantom study.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Mustafa C Altunbas; Lingyun Chen; Tao Han; Tianpeng Wang
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

3.  Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Tianpeng Wang
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

4.  An alternate line erasure and readout (ALER) method for implementing slot-scan imaging technique with a flat-panel detector--initial experiences.

Authors:  Xinming Liu; Chris C Shaw; Mustafa C Altunbas; Tianpeng Wang
Journal:  IEEE Trans Med Imaging       Date:  2006-04       Impact factor: 10.048

5.  Experimental realization of fluence field modulated CT using digital beam attenuation.

Authors:  T P Szczykutowicz; C A Mistretta
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609

6.  Role of equalisation mammography of dense breasts.

Authors:  D B Plewes; J M Sabol; I Soutar; A Chevrier; R Shumak
Journal:  Med Biol Eng Comput       Date:  1995-03       Impact factor: 2.602

7.  Scan equalization digital radiography (SEDR) implemented with an amorphous selenium flat-panel detector: initial experience.

Authors:  Xinming Liu; Chao-Jen Lai; Lingyun Chen; Tao Han; Yuncheng Zhong; Youtao Shen; Tianpeng Wang; Chris C Shaw
Journal:  Phys Med Biol       Date:  2009-11-04       Impact factor: 3.609

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.